Nitrous Oxide-Acetylene Flame AAS for Refractory Elements — product photo

Nitrous Oxide-Acetylene Flame AAS for Refractory Elements

难熔元素一氧化二氮-乙炔火焰原子吸收光谱仪

  • SKU FLA-0004
  • Flame AAS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range185–900 nm
Flame temperature2900–3000 °C (N2O-acetylene)
Burner typesN2O and air-acetylene
ElementsAl, Ti, V, Si, Mo, B, rare earths
Detection limit0.01–1 mg/L typical
Gas controlautomatic with sequencing
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals

What is the Nitrous Oxide-Acetylene Flame AAS for Refractory Elements?

This flame AAS is configured with a nitrous oxide-acetylene burner for refractory elements that form stable oxides. It is selected for aluminum, titanium, vanadium, silicon and molybdenum determinations in metals, minerals and ceramics.

What is the Nitrous Oxide-Acetylene Flame AAS for Refractory Elements?

This flame AAS is configured with a nitrous oxide-acetylene burner for refractory elements that form stable oxides. It is selected for aluminum, titanium, vanadium, silicon and molybdenum determinations in metals, minerals and ceramics.

Overview

Nitrous oxide-acetylene flames reach about 2900 to 3000 degrees Celsius, hot enough to atomize elements that remain as refractory oxides in the cooler air-acetylene flame. The burner has a shorter slot and different gas ratios to control the higher burning velocity, and the instrument requires rigid safety provisions including flashback arrestors, correct gas sequencing and restricted ignition procedures. Chemical interferences are still significant, so releasing agents such as lanthanum, strontium or potassium are added to suppress matrix effects, and calibration uses matrix-matched standards. Observation height and flame stoichiometry are optimized per element. Typical applications include aluminum alloys, geological and ceramic materials, catalysts and specialty chemicals. Many laboratories also keep an air-acetylene burner for routine elements and switch only when refractory elements are required.

How does it work?

A peristaltic pump or the nebulizer vacuum draws sample into a nebulizer, where it forms an aerosol that mixes with fuel and oxidant gases in a burner head. Combustion produces a steady cloud of ground-state atoms. A hollow-cathode lamp specific to the element emits sharp resonance lines that pass through the flame to a monochromator and photodetector. Absorbance is proportional to concentration according to the Beer-Lambert law. The flame composition, burner slot geometry and observation height are chosen so that atomization is efficient and chemical interferences are limited. Deuterium or Zeeman background correction removes signals from smoke, droplets and molecular species. Calibration is performed with aqueous standards matched to the sample acid and matrix, and burner rotation or a flow spoiler extends the linear range for concentrated samples.

What are the key features?

  • Nitrous oxide-acetylene burner for refractory elements
  • Reinforced gas handling with flashback arrestors
  • Automatic gas sequencing and restricted ignition
  • Supports releasing agents for interference control
  • Interchangeable air-acetylene burner for routine elements
  • Optimized observation height for each element

What are the technical specifications?

A typical nitrous oxide-acetylene flame aas for refractory elements configuration offers wavelength range of 185–900 nm, flame temperature of 2900–3000 °C (N2O-acetylene), burner types of N2O and air-acetylene, elements of Al, Ti, V, Si, Mo, B, rare earths, detection limit of 0.01–1 mg/L typical and gas control of automatic with sequencing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Nitrous Oxide-Acetylene Flame AAS for Refractory Elements is used in aluminum and titanium alloy composition, geological and mineral sample analysis, ceramic and glass raw material testing and catalyst and specialty chemical analysis. Across the wider Flame AAS class, laboratories also deploy it for metals in drinking water and wastewater, soil, plant and fertilizer nutrient analysis and food and beverage mineral and toxic metal testing.

Which standards and certifications apply?

Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals, US EPA Method 7000B, ASTM D4691 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Flame atomic absorption requires a flame hood, secure gas cylinders, regulators and flashback arrestors, with acetylene kept away from oxidizing materials. Install the instrument on a stable bench away from strong drafts, because airflow disturbs the flame. Daily checks include gas pressure, burner cleanliness and calibration verification. The burner slot and nebulizer need periodic cleaning to remove salt deposits that cause noise and drift. Hollow-cathode lamps have limited life and may need warm-up and alignment. Sample solutions should be filtered and matched to standards in acid content, and method blanks track contamination. Keep service and lamp records for traceability.

How do I select the right Nitrous Oxide-Acetylene Flame AAS for Refractory Elements?

Select this configuration when refractory elements are part of the routine element list and flame AAS is preferred over ICP. Confirm that nitrous oxide supply, regulators and ventilation meet safety requirements, and that operators are trained for the hotter flame. Specify the releasing agent chemistry and matrix-matched standards you will use, since these strongly affect accuracy.

How does it compare with other Flame AAS variants?

Select a flame system by the element list, concentration range and matrix. Single-beam optics suit most routine work at lower cost, while double-beam optics reduce drift from lamp and detector fluctuations for long unattended runs. An autosampler is essential for throughput and reproducibility in quality-control laboratories. If refractory elements such as aluminum, titanium or vanadium are required, choose a system with a nitrous oxide-acetylene burner and appropriate safety provisions. Alkali metals can be measured in flame emission mode, which improves sensitivity and avoids hollow-cathode lamp cost. Confirm burner materials suit your acid and dissolved-solids levels, and check that the gas control and interlocks meet local regulations.

Full specifications

Full specifications
Wavelength range185–900 nm
Flame temperature2900–3000 °C (N2O-acetylene)
Burner typesN2O and air-acetylene
ElementsAl, Ti, V, Si, Mo, B, rare earths
Detection limit0.01–1 mg/L typical
Gas controlautomatic with sequencing
Safety featuresflashback arrestors, interlocks
Releasing agentlanthanum or strontium salts
Nebulizerinert high-solids type
InterfaceUSB / RS-232

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Aluminum and titanium alloy composition
  • Geological and mineral sample analysis
  • Ceramic and glass raw material testing
  • Catalyst and specialty chemical analysis

Key features

  • Nitrous oxide-acetylene burner for refractory elements
  • Reinforced gas handling with flashback arrestors
  • Automatic gas sequencing and restricted ignition
  • Supports releasing agents for interference control
  • Interchangeable air-acetylene burner for routine elements
  • Optimized observation height for each element

Frequently asked questions about Nitrous Oxide-Acetylene Flame AAS for Refractory Elements

Nitrous oxide is a strong oxidizer and the flame has a higher burning velocity, so the risk of flashback into the gas lines is greater. Correct regulators, flashback arrestors, gas sequencing and burner design are mandatory. Operators must follow a written ignition and shutdown procedure, and nitrous oxide lines should not share components with other gases.