Single-Beam Flame Atomic Absorption Spectrometer
单光束火焰原子吸收光谱仪
- SKU FLA-0001
- Flame AAS
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength range | 185–900 nm |
|---|---|
| Optical system | single-beam Czerny-Turner |
| Spectral bandwidth | 0.1–2.0 nm selectable |
| Flame type | air-acetylene standard |
| Detection limit | 0.001–0.1 mg/L typical |
| Lamp turret | 4 hollow-cathode lamps |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals
What is the Single-Beam Flame Atomic Absorption Spectrometer?
A single-beam flame atomic absorption spectrometer uses one light path from lamp to detector. It is the economical, compact choice for routine metals analysis at milligram per litre levels in water, soil and food laboratories.
What is the Single-Beam Flame Atomic Absorption Spectrometer?
A single-beam flame atomic absorption spectrometer uses one light path from lamp to detector. It is the economical, compact choice for routine metals analysis at milligram per litre levels in water, soil and food laboratories.
Overview
This instrument places the hollow-cathode lamp, flame, monochromator and detector in one optical axis, which simplifies alignment and reduces cost and size. The trade-off is that lamp intensity drift and detector noise appear directly in the baseline, so the operator must allow lamp warm-up and may need more frequent recalibration. Typical optics cover 185 to 900 nanometers with a Czerny-Turner monochromator and selectable bandwidth, and deuterium background correction is standard. Flame options include air-acetylene for most elements, with a nitrous oxide burner as an option. Manual or automatic gas control, a lamp turret and an optional autosampler complete the system. The design is well suited to teaching, small laboratories and routine quality control where sample loads are moderate and the element list is stable.
How does it work?
A peristaltic pump or the nebulizer vacuum draws sample into a nebulizer, where it forms an aerosol that mixes with fuel and oxidant gases in a burner head. Combustion produces a steady cloud of ground-state atoms. A hollow-cathode lamp specific to the element emits sharp resonance lines that pass through the flame to a monochromator and photodetector. Absorbance is proportional to concentration according to the Beer-Lambert law. The flame composition, burner slot geometry and observation height are chosen so that atomization is efficient and chemical interferences are limited. Deuterium or Zeeman background correction removes signals from smoke, droplets and molecular species. Calibration is performed with aqueous standards matched to the sample acid and matrix, and burner rotation or a flow spoiler extends the linear range for concentrated samples.
What are the key features?
- Single optical path with simple alignment and compact footprint
- Czerny-Turner monochromator with selectable spectral bandwidth
- Deuterium background correction as standard
- Air-acetylene flame with optional nitrous oxide burner
- Multi-lamp turret for rapid element change
- Optional autosampler for routine sequences
What are the technical specifications?
A typical single-beam flame atomic absorption spectrometer configuration offers wavelength range of 185–900 nm, optical system of single-beam Czerny-Turner, spectral bandwidth of 0.1–2.0 nm selectable, flame type of air-acetylene standard, detection limit of 0.001–0.1 mg/L typical and lamp turret of 4 hollow-cathode lamps. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Single-Beam Flame Atomic Absorption Spectrometer is used in routine metals in water and wastewater, soil and plant nutrient analysis, food mineral content checks and teaching and small-laboratory analyses. Across the wider Flame AAS class, laboratories also deploy it for metals in drinking water and wastewater, soil, plant and fertilizer nutrient analysis and food and beverage mineral and toxic metal testing.
Which standards and certifications apply?
Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals, US EPA Method 7000B, ASTM D4691 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Flame atomic absorption requires a flame hood, secure gas cylinders, regulators and flashback arrestors, with acetylene kept away from oxidizing materials. Install the instrument on a stable bench away from strong drafts, because airflow disturbs the flame. Daily checks include gas pressure, burner cleanliness and calibration verification. The burner slot and nebulizer need periodic cleaning to remove salt deposits that cause noise and drift. Hollow-cathode lamps have limited life and may need warm-up and alignment. Sample solutions should be filtered and matched to standards in acid content, and method blanks track contamination. Keep service and lamp records for traceability.
How do I select the right Single-Beam Flame Atomic Absorption Spectrometer?
Select the single-beam variant when cost, simplicity and a stable, modest element list are the priorities. Specify the elements, working ranges, flame types and whether an autosampler is needed. Because baseline drift is more visible than in double-beam designs, allow lamp warm-up and define a calibration verification interval in the method.
How does it compare with other Flame AAS variants?
Select a flame system by the element list, concentration range and matrix. Single-beam optics suit most routine work at lower cost, while double-beam optics reduce drift from lamp and detector fluctuations for long unattended runs. An autosampler is essential for throughput and reproducibility in quality-control laboratories. If refractory elements such as aluminum, titanium or vanadium are required, choose a system with a nitrous oxide-acetylene burner and appropriate safety provisions. Alkali metals can be measured in flame emission mode, which improves sensitivity and avoids hollow-cathode lamp cost. Confirm burner materials suit your acid and dissolved-solids levels, and check that the gas control and interlocks meet local regulations.
Full specifications
| Wavelength range | 185–900 nm |
|---|---|
| Optical system | single-beam Czerny-Turner |
| Spectral bandwidth | 0.1–2.0 nm selectable |
| Flame type | air-acetylene standard |
| Detection limit | 0.001–0.1 mg/L typical |
| Lamp turret | 4 hollow-cathode lamps |
| Background correction | deuterium lamp |
| Nebulizer uptake | 4–6 mL/min |
| Gas control | manual or automatic |
| Interface | USB / RS-232 |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine metals in water and wastewater
- Soil and plant nutrient analysis
- Food mineral content checks
- Teaching and small-laboratory analyses
Key features
- Single optical path with simple alignment and compact footprint
- Czerny-Turner monochromator with selectable spectral bandwidth
- Deuterium background correction as standard
- Air-acetylene flame with optional nitrous oxide burner
- Multi-lamp turret for rapid element change
- Optional autosampler for routine sequences
Frequently asked questions about Single-Beam Flame Atomic Absorption Spectrometer
Yes, when operated with lamp warm-up, frequent calibration verification and background correction, single-beam instruments produce results suitable for regulated methods. Double-beam optics mainly improve stability during long unattended runs. The validated method, standards and quality control samples determine accuracy more than the beam configuration does.
Most single-beam instruments hold four to eight hollow-cathode lamps in a motorized turret, so the method can switch elements without manual changes. Each lamp still needs its own alignment check and warm-up. Multi-element lamps can reduce turret positions but generally perform less well than single-element lamps.
Allow at least 15 to 30 minutes for the lamp and electronics to stabilize, and longer for some elements. The flame itself stabilizes within a few minutes once gases and uptake rate are set. Methods should state warm-up conditions because sensitivity and baseline can change during this period.
Flame atomic absorption usually measures metals from about 0.001 to 100 milligrams per litre, depending on the element and flame conditions. Copper, zinc, iron and manganese are comfortably in this range. Below about 0.01 milligrams per litre, graphite furnace atomic absorption or ICP techniques offer lower detection limits with better reliability.
The flame produces heat, metal vapors and combustion products, and samples may contain acids and toxic elements. A flame hood removes these emissions and protects operators. It also stabilizes the environment around the burner so the flame is not disturbed by room air movement, which improves measurement reproducibility.
Use nitrous oxide-acetylene for refractory elements that form stable oxides in the cooler air-acetylene flame, such as aluminum, titanium, vanadium, silicon and molybdenum. The hotter flame improves atomization, but it also increases chemical interference risk, requires special burner heads and must be handled with additional safety precautions.