End-Heated Graphite Furnace Atomic Absorption Spectrometer

端部加热石墨炉原子吸收光谱仪

  • SKU GFA-0002
  • Graphite Furnace AAS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Atomizerend-heated graphite tube
Maximum temperature2800–3000 °C
Heating rateup to 1500 °C/s
Detection limit0.01–1 µg/L typical
Background correctiondeuterium or Zeeman
Sample volume5–50 µL
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, US EPA Method 7010 Graphite furnace atomic absorption spectrophotometry

What is the End-Heated Graphite Furnace Atomic Absorption Spectrometer?

An end-heated graphite furnace AAS passes current along the tube length from cooled end contacts. It is the cost-effective choice for routine trace-metal analysis where the most difficult matrices are not required.

What is the End-Heated Graphite Furnace Atomic Absorption Spectrometer?

An end-heated graphite furnace AAS passes current along the tube length from cooled end contacts. It is the cost-effective choice for routine trace-metal analysis where the most difficult matrices are not required.

Overview

In this classic design the tube ends are held in cooled electrode assemblies and current flows along the tube, producing the highest temperature at the center and cooler zones near the ends. It is mechanically simple, uses inexpensive tubes and has a large installed base, making it economical for routine work. The temperature gradient can cause condensation of volatile analytes at the cooler ends, so peak shapes may be slightly broader and memory effects can occur with elements such as cadmium. Careful temperature programming, the use of a platform and matrix modifiers reduce these effects. Deuterium or Zeeman background correction can be fitted, and autosamplers with modifier dosing are widely available. The design suits water, environmental and food testing where matrices are well characterized and detection limits are moderate.

How does it work?

A measured aliquot of sample, typically 5 to 50 microlitres, is deposited into a graphite tube through a dosing hole. The tube is heated in programmed stages: drying to evaporate solvent, pyrolysis to remove organic and inorganic matrix, atomization at high temperature to create a transient cloud of free atoms, and cleaning to remove residue. A hollow-cathode lamp emits the element resonance line through the tube, and the detector records a transient absorbance peak whose area is proportional to the analyte mass. Because atomization is efficient and atoms remain in the optical path longer than in a flame, detection limits are far lower, often in the nanogram per litre range for cadmium and lead. Strong background correction by Zeeman effect or deuterium lamp is essential, and matrix modifiers stabilize analytes during pyrolysis. Tubes and platforms are consumables, and temperature programs are optimized for each matrix.

What are the key features?

  • Current flows along the tube from cooled end contacts
  • Simple, low-cost tube and electrode design
  • Widely available tubes and accessories
  • Deuterium or Zeeman background correction options
  • Autosampler with matrix modifier dosing
  • Optimized temperature programs for routine matrices

What are the technical specifications?

A typical end-heated graphite furnace atomic absorption spectrometer configuration offers atomizer of end-heated graphite tube, maximum temperature of 2800–3000 °C, heating rate of up to 1500 °C/s, detection limit of 0.01–1 µg/L typical, background correction of deuterium or Zeeman and sample volume of 5–50 µL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The End-Heated Graphite Furnace Atomic Absorption Spectrometer is used in routine trace metals in drinking water, environmental water and soil digests, food lead and cadmium screening and industrial effluent monitoring. Across the wider Graphite Furnace AAS class, laboratories also deploy it for trace metals in drinking water and wastewater, lead and cadmium in food, blood and urine and elemental impurities in pharmaceutical materials.

Which standards and certifications apply?

Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, US EPA Method 7010 Graphite furnace atomic absorption spectrophotometry, ISO 15586 Water quality — Determination of trace elements by graphite furnace AAS, ICH Q2(R2) Validation of analytical procedures and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Graphite furnace systems need argon of high purity, a stable power supply, temperature-controlled cooling and adequate exhaust for pyrolysis vapors. Acid digestion or dilution precedes most measurements, and ultrapure reagents and clean vessels are essential because contamination is visible at nanogram per litre levels. Matrix modifiers must be prepared accurately and dosed reproducibly. Operating cost is dominated by graphite tubes, platforms and lamps, so tracking firings and sensitivity helps schedule replacement. Daily checks include autosampler alignment, blank levels and calibration verification. Because each matrix behaves differently, temperature programs require development and should be fixed in the method with defined acceptance criteria.

How do I select the right End-Heated Graphite Furnace Atomic Absorption Spectrometer?

Select an end-heated furnace for routine trace analysis when tube costs, simplicity and a proven design matter more than the ultimate performance on difficult matrices. Specify the elements, detection limits and matrices. If volatile elements or complex samples show memory effects, a transversely heated furnace may be more suitable.

How does it compare with other Graphite Furnace AAS variants?

Choose a graphite furnace system when trace or ultratrace detection limits are required for a limited number of elements and sample volumes are small. Transverse-heated tubes give more uniform temperature and better reproducibility, while end-heated tubes are simpler and less costly. Zeeman background correction is preferred for complex matrices that produce high structured background. An autosampler with modifier dosing and automatic dilution is important for throughput and for reproducible standard addition. Simultaneous multi-element instruments reduce analysis time when several elements are required, but single-element sequential operation remains the most common and lowest-cost approach. Confirm the graphite tube type and coating suit your elements, since carbide-forming elements such as silicon and vanadium require special tubes.

Full specifications

Full specifications
Atomizerend-heated graphite tube
Maximum temperature2800–3000 °C
Heating rateup to 1500 °C/s
Detection limit0.01–1 µg/L typical
Background correctiondeuterium or Zeeman
Sample volume5–50 µL
Platformoptional
Purge gasargon, 200–300 mL/min
Tube life200–1000 firings
Autosampler positions60–120 vials

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Routine trace metals in drinking water
  • Environmental water and soil digests
  • Food lead and cadmium screening
  • Industrial effluent monitoring

Key features

  • Current flows along the tube from cooled end contacts
  • Simple, low-cost tube and electrode design
  • Widely available tubes and accessories
  • Deuterium or Zeeman background correction options
  • Autosampler with matrix modifier dosing
  • Optimized temperature programs for routine matrices

Frequently asked questions about End-Heated Graphite Furnace Atomic Absorption Spectrometer

Analyte vapor condenses on the cooler tube ends and is released in later firings, adding to the signal of subsequent samples. Volatile elements such as cadmium are most prone. Higher cleanout temperatures, a platform, matrix modifiers and longer cleaning steps reduce the effect, and blanks between samples detect it.