Automated Flame AAS with Autosampler
自动进样火焰原子吸收光谱仪
- SKU FLA-0003
- Flame AAS
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- 21 CFR Part 11 software compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sampler positions | 60–180 vials |
|---|---|
| Throughput | 100–300 determinations/h |
| Rinse cycles | programmable, 1–5 |
| Dilution capability | automatic, up to 100:1 |
| Wavelength range | 185–900 nm |
| Optical system | double-beam |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals
What is the Automated Flame AAS with Autosampler?
An automated flame AAS with autosampler handles calibration standards, samples and quality-control checks without operator intervention. It is chosen for routine, high-throughput laboratories that need consistent productivity, fewer transcription errors and traceable measurement sequences.
What is the Automated Flame AAS with Autosampler?
An automated flame AAS with autosampler handles calibration standards, samples and quality-control checks without operator intervention. It is chosen for routine, high-throughput laboratories that need consistent productivity, fewer transcription errors and traceable measurement sequences.
Overview
This configuration combines a flame spectrometer with a robotic sampler that rinses, aspirates and delivers each solution in a programmed sequence. Software stores the calibration, quality-control and sample order, performs recalibration or reanalysis rules, and logs results against sample identities. Automatic dilution and standard addition reduce manual preparation, and intelligent rinse cycles limit carry-over between high and low concentrations. The system can run overnight and flag failed QC samples for review. It is typically paired with automatic gas control, a multi-lamp turret and background correction, and often with double-beam optics for baseline stability. Typical throughput is 100 to 300 determinations per hour depending on element and read time. The main value is fewer transcription errors, more consistent timing and full traceability of every solution measured.
How does it work?
A peristaltic pump or the nebulizer vacuum draws sample into a nebulizer, where it forms an aerosol that mixes with fuel and oxidant gases in a burner head. Combustion produces a steady cloud of ground-state atoms. A hollow-cathode lamp specific to the element emits sharp resonance lines that pass through the flame to a monochromator and photodetector. Absorbance is proportional to concentration according to the Beer-Lambert law. The flame composition, burner slot geometry and observation height are chosen so that atomization is efficient and chemical interferences are limited. Deuterium or Zeeman background correction removes signals from smoke, droplets and molecular species. Calibration is performed with aqueous standards matched to the sample acid and matrix, and burner rotation or a flow spoiler extends the linear range for concentrated samples.
What are the key features?
- Robotic autosampler with up to 120 or more positions
- Automatic dilution and standard addition
- Programmable calibration and QC reanalysis rules
- Intelligent rinse to limit carry-over
- Result logging tied to sample identities
- Overnight unattended operation
What are the technical specifications?
A typical automated flame aas with autosampler configuration offers sampler positions of 60–180 vials, throughput of 100–300 determinations/h, rinse cycles of programmable, 1–5, dilution capability of automatic, up to 100:1, wavelength range of 185–900 nm and optical system of double-beam. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Flame AAS with Autosampler is used in high-volume drinking water compliance testing, environmental soil and sediment programs, food and beverage routine mineral testing and pharmaceutical catalyst residue screening. Across the wider Flame AAS class, laboratories also deploy it for metals in drinking water and wastewater, soil, plant and fertilizer nutrient analysis and food and beverage mineral and toxic metal testing.
Which standards and certifications apply?
Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals, US EPA Method 7000B, ASTM D4691 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Flame atomic absorption requires a flame hood, secure gas cylinders, regulators and flashback arrestors, with acetylene kept away from oxidizing materials. Install the instrument on a stable bench away from strong drafts, because airflow disturbs the flame. Daily checks include gas pressure, burner cleanliness and calibration verification. The burner slot and nebulizer need periodic cleaning to remove salt deposits that cause noise and drift. Hollow-cathode lamps have limited life and may need warm-up and alignment. Sample solutions should be filtered and matched to standards in acid content, and method blanks track contamination. Keep service and lamp records for traceability.
How do I select the right Automated Flame AAS with Autosampler?
Select an automated system when sample volume is high and consistent operation matters, for example compliance monitoring or contract testing. Specify sampler capacity, dilution range, QC rules and whether results must feed a laboratory information management system. Confirm that carry-over specifications meet your lowest concentration requirements and that the software supports the audit trail your quality system needs.
How does it compare with other Flame AAS variants?
Select a flame system by the element list, concentration range and matrix. Single-beam optics suit most routine work at lower cost, while double-beam optics reduce drift from lamp and detector fluctuations for long unattended runs. An autosampler is essential for throughput and reproducibility in quality-control laboratories. If refractory elements such as aluminum, titanium or vanadium are required, choose a system with a nitrous oxide-acetylene burner and appropriate safety provisions. Alkali metals can be measured in flame emission mode, which improves sensitivity and avoids hollow-cathode lamp cost. Confirm burner materials suit your acid and dissolved-solids levels, and check that the gas control and interlocks meet local regulations.
Full specifications
| Sampler positions | 60–180 vials |
|---|---|
| Throughput | 100–300 determinations/h |
| Rinse cycles | programmable, 1–5 |
| Dilution capability | automatic, up to 100:1 |
| Wavelength range | 185–900 nm |
| Optical system | double-beam |
| Flame types | air-acetylene, N2O-acetylene |
| Background correction | deuterium |
| QC functions | blank, drift, spike recovery |
| Interface | Ethernet / USB |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-volume drinking water compliance testing
- Environmental soil and sediment programs
- Food and beverage routine mineral testing
- Pharmaceutical catalyst residue screening
Key features
- Robotic autosampler with up to 120 or more positions
- Automatic dilution and standard addition
- Programmable calibration and QC reanalysis rules
- Intelligent rinse to limit carry-over
- Result logging tied to sample identities
- Overnight unattended operation
Frequently asked questions about Automated Flame AAS with Autosampler
The sampler rinses the uptake tubing and nebulizer with dilute acid between samples, and software can add extra rinses after high-concentration samples. Using separate standard and sample positions and minimizing tubing length also help. Carry-over is verified during method validation at the lowest calibration level.
Yes, many autosamplers aspirate a measured volume of sample and diluent to bring the concentration into range, then apply the dilution factor to the reported result. Automatic dilution saves operator time but must be validated for accuracy and for the diluent chemistry that suits the method.
Typical rules include a method blank, calibration verification standards at the start and end, a continuing calibration check every ten samples, a matrix spike and a duplicate. Acceptance limits and actions such as recalibration or reanalysis are defined in the method and enforced by the software for traceability.
Flame atomic absorption usually measures metals from about 0.001 to 100 milligrams per litre, depending on the element and flame conditions. Copper, zinc, iron and manganese are comfortably in this range. Below about 0.01 milligrams per litre, graphite furnace atomic absorption or ICP techniques offer lower detection limits with better reliability.
The flame produces heat, metal vapors and combustion products, and samples may contain acids and toxic elements. A flame hood removes these emissions and protects operators. It also stabilizes the environment around the burner so the flame is not disturbed by room air movement, which improves measurement reproducibility.
Use nitrous oxide-acetylene for refractory elements that form stable oxides in the cooler air-acetylene flame, such as aluminum, titanium, vanadium, silicon and molybdenum. The hotter flame improves atomization, but it also increases chemical interference risk, requires special burner heads and must be handled with additional safety precautions.