Motorized Cryostat
电动恒冷箱切片机
- SKU CRY-0003
- Cryostats
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- IEC 61326-1 EMC (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber temperature range | –5 to –35 °C |
|---|---|
| Specimen temperature range | –10 to –40 °C |
| Section thickness range | 1–100 µm |
| Cutting speed | 50–400 mm/s, adjustable |
| Thickness increment | 1 µm |
| Retraction | 0–200 µm, programmable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1
What is the Motorized Cryostat?
A motorized cryostat drives the cutting stroke with a motor inside the cold chamber, reducing operator strain and improving section consistency. It is chosen for high-volume frozen section services and repetitive research sectioning.
What is the Motorized Cryostat?
A motorized cryostat drives the cutting stroke with a motor inside the cold chamber, reducing operator strain and improving section consistency. It is chosen for high-volume frozen section services and repetitive research sectioning.
Overview
In a motorized cryostat the cutting stroke is driven by a motor rated for cold operation, while the operator controls specimen approach and orientation. Adjustable speed typically ranges from about 50 to 400 mm/s, so soft tissue can be cut slowly and firm blocks faster. Motorised models reduce the repetitive handwheel motion that causes shoulder and wrist strain in busy frozen section services, and they produce more consistent stroke speed than manual cutting. Many include a foot pedal, emergency stop and an automatic return to the start position. Section thickness still follows the same 1 to 100 µm range as manual models, and retraction is programmable. Because the drive sits inside the cold zone, reliability and ease of servicing should be checked before purchase.
How does it work?
A cryostat places a microtome inside an insulated chamber cooled by one or two refrigeration compressors. The chamber and often a separate specimen stage are brought to between –15 and –35 °C, freezing the tissue to a suitable hardness. The operator attaches the frozen block to a chuck with embedding medium and sections it with a disposable blade held at a fixed angle, producing sections typically 1 to 100 µm thick. Sections adhere to room-temperature slides and are fixed immediately in alcohol or acetone. Anti-roll plates and brush techniques guide ribbons free of curling. Because the whole cutting zone stays cold, tissue morphology is preserved without paraffin infiltration, and total turnaround from specimen to stained slide can be under 20 minutes.
What are the key features?
- Motor-driven cutting stroke rated for cold chamber use
- Adjustable cutting speed about 50 to 400 mm/s
- Foot pedal and emergency stop control
- Programmable retraction and automatic return
- Reduces repetitive strain in high-volume services
- Section thickness 1 to 100 µm
What are the technical specifications?
A typical motorized cryostat configuration offers chamber temperature range of –5 to –35 °C, specimen temperature range of –10 to –40 °C, section thickness range of 1–100 µm, cutting speed of 50–400 mm/s, adjustable, thickness increment of 1 µm and retraction of 0–200 µm, programmable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Motorized Cryostat is used in high-volume frozen section services, repetitive research sectioning, laboratories with ergonomic concerns and mohs micrographic surgery. Across the wider Cryostats class, laboratories also deploy it for intraoperative frozen sections, immunofluorescence on fresh tissue and enzyme histochemistry.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189 and ISO 13485. Certification candidates for this model are CE, IEC 61010-1 compliance and IEC 61326-1 EMC; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the cryostat in a room kept below 25 °C with good ventilation, because condensers reject significant heat. Allow several hours for initial cool-down, then verify chamber and specimen temperatures against a calibrated thermometer. Defrost and clean the chamber on schedule; residual cryo-embedding medium degrades section quality. Use anti-roll plates and change blades often. Monitor for frost build-up, compressor noise and door seal condition, and service annually. Maintain temperature logs, cleaning records and staff training, since these documents support accreditation of frozen section services.
How do I select the right Motorized Cryostat?
Specify a motorized cryostat when daily frozen section volume is high, when operators report shoulder or wrist strain, or when stroke speed must be reproducible across a study. Confirm that the motor is rated for continuous cold operation and that service access is practical. State speed range, retraction settings and control type.
How does it compare with other Cryostats variants?
Choose a cryostat by the work it must support. Clinical laboratories doing intraoperative frozen sections need fast cool-down, a stable chamber near –20 °C, reliable blade cooling and often UV sterilisation for contamination control. Research and immunohistochemistry laboratories value accurate independent specimen cooling, wide temperature range to –35 °С and a motorised or ergonomic cutting system for repetitive work. Confirm chamber and specimen temperature ranges, cool-down time, defrost cycle, section thickness range, blade type and whether the cutting area can be cleaned with the chamber at working temperature. Also check section transfer options and the footprint of the lab bench.
Full specifications
| Chamber temperature range | –5 to –35 °C |
|---|---|
| Specimen temperature range | –10 to –40 °C |
| Section thickness range | 1–100 µm |
| Cutting speed | 50–400 mm/s, adjustable |
| Thickness increment | 1 µm |
| Retraction | 0–200 µm, programmable |
| Control | Foot pedal and front panel |
| Cool-down time | about 2 h |
| Power supply | 220 V, 50 Hz, about 1.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-volume frozen section services
- Repetitive research sectioning
- Laboratories with ergonomic concerns
- Mohs micrographic surgery
Key features
- Motor-driven cutting stroke rated for cold chamber use
- Adjustable cutting speed about 50 to 400 mm/s
- Foot pedal and emergency stop control
- Programmable retraction and automatic return
- Reduces repetitive strain in high-volume services
- Section thickness 1 to 100 µm
Frequently asked questions about Motorized Cryostat
It improves consistency because stroke speed is the same for every section, which helps serial sections and quantitative work. Section quality still depends on tissue temperature, blade condition and correct anti-roll plate setup.
It has additional moving parts inside the cold chamber, so drive belts, gears or linear actuators may need periodic inspection. Ask for the recommended service interval, spare part availability and whether the drive can be accessed without full warm-up.
Yes, speed is normally selectable before or during a session. Use slow speeds for soft, fatty or fragile tissue where heat builds up, and faster speeds for firm blocks. Changing speed mid-run is best avoided when cutting a matched series.
A cryostat cuts frozen tissue sections inside a refrigerated chamber. It is used for rapid intraoperative diagnosis, for immunohistochemistry and enzyme work that need unfixed tissue, and for research when native morphology or antigen preservation is important.
Most frozen sections are cut with the chamber between –18 and –25 °C, and the specimen stage matched or set a few degrees colder for dense tissue. Fatty or soft tissue may need –30 °C, while delicate tissue such as lymph node is often cut nearer –15 °C.
Shredding usually means the tissue or chamber is too cold, the block is too thick or the blade is blunt. Crumpling can indicate the tissue is too warm. Adjust chamber and specimen temperature, use a fresh blade, trim to size and cut at a slow, steady speed.
Related models