Clinical Cryostat

临床恒冷箱切片机

  • SKU CRY-0001
  • Cryostats
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • IEC 61326-1 EMC (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber temperature range–5 to –30 °C
Typical working temperature–20 °C
Cool-down timeabout 1–2 h
Section thickness range1–60 µm
Thickness increment1 µm
Specimen stageIndependent, to –40 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1

What is the Clinical Cryostat?

A clinical cryostat is optimised for rapid intraoperative frozen sections, with fast cool-down, a stable chamber near –20 °C and simple controls. It is the standard instrument in hospital surgical pathology suites.

What is the Clinical Cryostat?

A clinical cryostat is optimised for rapid intraoperative frozen sections, with fast cool-down, a stable chamber near –20 °C and simple controls. It is the standard instrument in hospital surgical pathology suites.

Overview

The clinical cryostat prioritises speed, reliability and ease of use. Chamber temperature is usually fixed near –20 °C with a single setpoint, or adjustable over a narrow range, because most frozen sections for diagnosis are cut at similar conditions. Cool-down takes one to two hours, and some models offer a fast-freeze stage that reaches –40 °C or lower for urgent blocks. Controls are deliberately simple so a rotating on-call pathologist or technician can operate the instrument without recalibration. A UV lamp or antimicrobial surfaces help control contamination between cases, and an anti-roll plate with a clear view of the knife makes ribbon handling easier. Typical section thickness spans 1 to 60 µm, and low-profile disposable blades keep consumable cost low.

How does it work?

A cryostat places a microtome inside an insulated chamber cooled by one or two refrigeration compressors. The chamber and often a separate specimen stage are brought to between –15 and –35 °C, freezing the tissue to a suitable hardness. The operator attaches the frozen block to a chuck with embedding medium and sections it with a disposable blade held at a fixed angle, producing sections typically 1 to 100 µm thick. Sections adhere to room-temperature slides and are fixed immediately in alcohol or acetone. Anti-roll plates and brush techniques guide ribbons free of curling. Because the whole cutting zone stays cold, tissue morphology is preserved without paraffin infiltration, and total turnaround from specimen to stained slide can be under 20 minutes.

What are the key features?

  • Chamber temperature stable near –20 °C
  • Fast cool-down in about one to two hours
  • Simple single-setpoint controls for on-call use
  • UV lamp or antimicrobial surfaces for contamination control
  • Optional rapid freezing stage to –40 °C
  • Section thickness about 1 to 60 µm

What are the technical specifications?

A typical clinical cryostat configuration offers chamber temperature range of –5 to –30 °C, typical working temperature of –20 °C, cool-down time of about 1–2 h, section thickness range of 1–60 µm, thickness increment of 1 µm and specimen stage of Independent, to –40 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Clinical Cryostat is used in intraoperative frozen section diagnosis, rapid margin assessment, mohs micrographic surgery and urgent immunohistochemistry. Across the wider Cryostats class, laboratories also deploy it for intraoperative frozen sections, immunofluorescence on fresh tissue and enzyme histochemistry.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1, ISO 15189 and ISO 13485. Certification candidates for this model are CE, IEC 61010-1 compliance and IEC 61326-1 EMC; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place the cryostat in a room kept below 25 °C with good ventilation, because condensers reject significant heat. Allow several hours for initial cool-down, then verify chamber and specimen temperatures against a calibrated thermometer. Defrost and clean the chamber on schedule; residual cryo-embedding medium degrades section quality. Use anti-roll plates and change blades often. Monitor for frost build-up, compressor noise and door seal condition, and service annually. Maintain temperature logs, cleaning records and staff training, since these documents support accreditation of frozen section services.

How do I select the right Clinical Cryostat?

Choose the clinical cryostat for surgical pathology where turnaround time is the priority. It is likely to be the only instrument in a small hospital, so reliability and service response matter. In the RFQ confirm chamber temperature stability, cool-down time, defrost programming, UV sterilisation, blade type and the emergency service agreement.

How does it compare with other Cryostats variants?

Choose a cryostat by the work it must support. Clinical laboratories doing intraoperative frozen sections need fast cool-down, a stable chamber near –20 °C, reliable blade cooling and often UV sterilisation for contamination control. Research and immunohistochemistry laboratories value accurate independent specimen cooling, wide temperature range to –35 °С and a motorised or ergonomic cutting system for repetitive work. Confirm chamber and specimen temperature ranges, cool-down time, defrost cycle, section thickness range, blade type and whether the cutting area can be cleaned with the chamber at working temperature. Also check section transfer options and the footprint of the lab bench.

Full specifications

Full specifications
Chamber temperature range–5 to –30 °C
Typical working temperature–20 °C
Cool-down timeabout 1–2 h
Section thickness range1–60 µm
Thickness increment1 µm
Specimen stageIndependent, to –40 °C
Blade typeDisposable low-profile
DefrostProgrammable cycle
Power supply220 V, 50 Hz, about 1 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Intraoperative frozen section diagnosis
  • Rapid margin assessment
  • Mohs micrographic surgery
  • Urgent immunohistochemistry

Key features

  • Chamber temperature stable near –20 °C
  • Fast cool-down in about one to two hours
  • Simple single-setpoint controls for on-call use
  • UV lamp or antimicrobial surfaces for contamination control
  • Optional rapid freezing stage to –40 °C
  • Section thickness about 1 to 60 µm

Frequently asked questions about Clinical Cryostat

From receipt of the specimen, a skilled technologist can produce a stained frozen section in about 10 to 20 minutes, including freezing, sectioning, fixation and rapid H&E staining. The pathologist then examines it while the operation continues.

Related models

All Cryostats
Research Cryostat — product photo

Research Cryostat

科研恒冷箱切片机

  • CE (to be confirmed)
  • +2
Request a quote
Motorized Cryostat — product photo

Motorized Cryostat

电动恒冷箱切片机

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Clinical Cryostat

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote