Direct-Heat CO2 Incubator
直热式 CO2 培养箱
- SKU CON-0003
- CO2 Incubators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50–180 L (model dependent) |
|---|---|
| Temperature range | ambient +5 to 50 °C, set at 37 °C |
| Temperature uniformity | within ±0.3–0.5 °C at 37 °C |
| CO2 range | 0–20%, controlled at 5% |
| CO2 accuracy | within ±0.1–0.3% |
| Humidity | above 90% relative humidity with water pan |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1
What is the Direct-Heat CO2 Incubator?
A direct-heat CO2 incubator places heating elements in the chamber walls and uses natural convection instead of a fan, giving fast warm-up, easy cleaning and no moving parts in the culture space at a lower capital cost.
What is the Direct-Heat CO2 Incubator?
A direct-heat CO2 incubator places heating elements in the chamber walls and uses natural convection instead of a fan, giving fast warm-up, easy cleaning and no moving parts in the culture space at a lower capital cost.
Overview
Heating foils or pads bonded to the chamber walls transfer heat directly, and air moves by natural convection, so there is no fan to disturb cultures, generate particles or create a cleaning obstacle. The absence of a fan also reduces contamination pathways, and the chamber can be emptied and wiped down quickly. Temperature uniformity is typically within ±0.3–0.5 °C, slightly wider than fan-assisted or water-jacketed designs, so shelves should not be overloaded. Warm-up takes about 20–40 minutes from ambient, and recovery after a short door opening is usually within 10 minutes. Direct-heat models are often stackable, energy efficient and inexpensive to service, making them a common choice for teaching, diagnostic and general research laboratories.
How does it work?
Cells in culture cannot regulate their own environment, so the incubator supplies what the medium cannot. Temperature is held at 37 °C by a water jacket, an air jacket or direct heating elements around the chamber, with a PID controller and an over-temperature cut-out. Carbon dioxide is measured by an infrared or thermal conductivity sensor and injected from a supply cylinder to maintain 5% CO2, which keeps bicarbonate-buffered medium at physiological pH. A water pan or humidity injection keeps relative humidity above 90%, preventing evaporation that would concentrate salts and osmolytes and change the pH set point. Copper-lined or antimicrobial interior panels and HEPA filters reduce contamination risk, and an inner glass door limits gas exchange when the outer door is opened. Some models add nitrogen to control oxygen for hypoxic culture.
What are the key features?
- Wall-mounted heating elements with natural convection airflow
- No fan in the culture space, simplifying cleaning
- Warm-up in about 20–40 minutes and recovery within 10 minutes
- Stackable cabinets with independent controllers
- Infrared CO2 sensor with humidity-independent control
- Removable shelves and rounded corners for decontamination
What are the technical specifications?
A typical direct-heat co2 incubator configuration offers chamber volume of 50–180 L (model dependent), temperature range of ambient +5 to 50 °C, set at 37 °C, temperature uniformity of within ±0.3–0.5 °C at 37 °C, CO2 range of 0–20%, controlled at 5%, CO2 accuracy of within ±0.1–0.3% and humidity of above 90% relative humidity with water pan. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Direct-Heat CO2 Incubator is used in teaching and general research culture, diagnostic sample culture, small-volume flask and plate work and laboratories with limited bench space and budget. Across the wider CO2 Incubators class, laboratories also deploy it for routine mammalian cell line culture, stem cell and primary cell maintenance and vaccine and recombinant protein production.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, EN 12469, ISO 14644-1 and USP <1046>. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the incubator on a level surface away from direct sunlight, heat sources and draughts, leaving clearance for the gas connection and ventilation. Fill the humidity pan with sterile distilled water and change it weekly, since stagnant water is a common contamination source; some models use humidity injection that avoids standing water. Verify temperature and CO2 accuracy at installation and at least every six months with a calibrated external instrument, and record recovery time after door opening. Do not overload shelves, because air circulation is needed for uniformity. Handle spills immediately, use only compatible disinfectants, and follow the manufacturer's decontamination procedure before servicing. Keep a log of cleaning, calibration and decontamination events so that culture problems can be traced.
How do I select the right Direct-Heat CO2 Incubator?
Select a direct-heat incubator when low cost, easy cleaning and quiet fan-free operation matter, and when temperature stability requirements are moderate. Specify chamber volume, shelf configuration, CO2 sensor type, stacking options and the contamination control features available.
How does it compare with other CO2 Incubators variants?
Choose the chamber type first. Water-jacketed incubators hold temperature most stably through power interruptions and suit laboratories with frequent door openings, while air-jacketed and direct-heat models warm up faster, are lighter and need less maintenance. Then consider contamination control: copper interior surfaces, HEPA filtration of the air circuit and high-temperature or vaporised hydrogen peroxide decontamination cycles reduce losses in busy laboratories. Check CO2 and temperature accuracy and uniformity, recovery time after door opening, humidity control, and whether oxygen control is needed for stem cell or hypoxia work. Review alarm functions, data logging, access control and remote monitoring if the incubator holds irreplaceable cultures or is part of a regulated process. Confirm stackability, shelf adjustability and available chamber volumes before ordering.
Full specifications
| Chamber volume | 50–180 L (model dependent) |
|---|---|
| Temperature range | ambient +5 to 50 °C, set at 37 °C |
| Temperature uniformity | within ±0.3–0.5 °C at 37 °C |
| CO2 range | 0–20%, controlled at 5% |
| CO2 accuracy | within ±0.1–0.3% |
| Humidity | above 90% relative humidity with water pan |
| Warm-up time | approx. 20–40 min from ambient |
| Airflow | Natural convection, fan-free |
| Stacking | Two or three units with stacking frames |
| Dimensions (W x D x H) | approx. 550 x 600 x 850 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Teaching and general research culture
- Diagnostic sample culture
- Small-volume flask and plate work
- Laboratories with limited bench space and budget
Key features
- Wall-mounted heating elements with natural convection airflow
- No fan in the culture space, simplifying cleaning
- Warm-up in about 20–40 minutes and recovery within 10 minutes
- Stackable cabinets with independent controllers
- Infrared CO2 sensor with humidity-independent control
- Removable shelves and rounded corners for decontamination
Frequently asked questions about Direct-Heat CO2 Incubator
Heating elements in the walls produce gentle natural convection, which is enough for uniformity in a well-designed chamber of this size. Removing the fan eliminates a cleaning obstacle, reduces particle generation and lowers the risk of spreading contaminants.
It is usually within ±0.3–0.5 °C, slightly wider than fan-assisted or water-jacketed models. Overloading shelves or placing a warm plate near the sensor can worsen it, so loading should follow the manufacturer's guidance.
Change the humidity pan water weekly, wipe surfaces with a compatible disinfectant, and verify temperature and CO2 twice a year with calibrated instruments. Without a fan, there is no bearing or filter in the air circuit to service.
Water-jacketed chambers hold temperature more stably during power cuts and heavy door use, but are heavier and need more maintenance. Air-jacketed and direct-heat units warm up faster, recover quickly and are easier to move, which suits most routine laboratories.
Without high humidity, medium evaporates and concentrates salts and proteins, raising osmolarity and shifting pH. This changes growth rates and can make results from long experiments inconsistent, especially in small-volume or multi-well formats.
Infrared sensors typically hold CO2 within ±0.1–0.3% of the set point and are unaffected by humidity, while thermal conductivity sensors are cheaper but sensitive to moisture. Accuracy should be verified with a calibrated analyser at least twice a year.