Skip to main content
Lab Manufacturers China
Water-Jacketed CO2 Incubator — product photo

Water-Jacketed CO2 Incubator

水套式 CO2 培养箱

  • SKU CON-0002
  • CO2 Incubators
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)
  • IEC 61010-2-010 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Chamber volume150–300 L (model dependent)
Temperature rangeambient +5 to 50 °C, set at 37 °C
Temperature uniformitywithin ±0.2 °C at 37 °C
Jacket volumeapprox. 20–40 L distilled water
CO2 range0–20%, controlled at 5%
CO2 accuracywithin ±0.1–0.3% (infrared sensor)
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1

What is the Water-Jacketed CO2 Incubator?

A water-jacketed CO2 incubator surrounds the chamber with a sealed water jacket that buffers temperature exceptionally well, holding 37 °C through power interruptions and frequent door use. It is chosen where culture stability is critical.

What is the Water-Jacketed CO2 Incubator?

A water-jacketed CO2 incubator surrounds the chamber with a sealed water jacket that buffers temperature exceptionally well, holding 37 °C through power interruptions and frequent door use. It is chosen where culture stability is critical.

Overview

A stainless steel jacket filled with distilled water surrounds the culture chamber, and a heating element warms the water, which then radiates heat into the chamber with very low fluctuation rate. Because of the large thermal mass, temperature falls only slowly during a power interruption or prolonged door opening, protecting irreplaceable cultures. Temperature uniformity across the chamber is typically within ±0.2 °C, and recovery after door opening is faster than in air-jacketed units once the door is closed. The cost is weight, since a large unit may contain 20–40 litres of water, and the need to drain and refill the jacket periodically with treated water to avoid corrosion and biological growth. Water-jacketed models are often used for stem cell, vaccine and clinical work.

How does it work?

Cells in culture cannot regulate their own environment, so the incubator supplies what the medium cannot. Temperature is held at 37 °C by a water jacket, an air jacket or direct heating elements around the chamber, with a PID controller and an over-temperature cut-out. Carbon dioxide is measured by an infrared or thermal conductivity sensor and injected from a supply cylinder to maintain 5% CO2, which keeps bicarbonate-buffered medium at physiological pH. A water pan or humidity injection keeps relative humidity above 90%, preventing evaporation that would concentrate salts and osmolytes and change the pH set point. Copper-lined or antimicrobial interior panels and HEPA filters reduce contamination risk, and an inner glass door limits gas exchange when the outer door is opened. Some models add nitrogen to control oxygen for hypoxic culture.

What are the key features?

  • Sealed water jacket buffering temperature during power interruptions
  • Temperature uniformity within about ±0.2 °C
  • Fast recovery once the door is closed
  • Infrared CO2 sensor with humidity-independent measurement
  • Copper-lined or antimicrobial interior options
  • Larger chamber volumes for high-density workloads

What are the technical specifications?

A typical water-jacketed co2 incubator configuration offers chamber volume of 150–300 L (model dependent), temperature range of ambient +5 to 50 °C, set at 37 °C, temperature uniformity of within ±0.2 °C at 37 °C, jacket volume of approx. 20–40 L distilled water, CO2 range of 0–20%, controlled at 5% and CO2 accuracy of within ±0.1–0.3% (infrared sensor). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Water-Jacketed CO2 Incubator is used in stem cell and primary cell culture, vaccine production and virus culture, clinical and cytogenetic laboratories and long-term culture of irreplaceable lines. Across the wider CO2 Incubators class, laboratories also deploy it for routine mammalian cell line culture, stem cell and primary cell maintenance and vaccine and recombinant protein production.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, EN 12469, ISO 14644-1 and USP <1046>. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IEC 61010-2-010 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the incubator on a level surface away from direct sunlight, heat sources and draughts, leaving clearance for the gas connection and ventilation. Fill the humidity pan with sterile distilled water and change it weekly, since stagnant water is a common contamination source; some models use humidity injection that avoids standing water. Verify temperature and CO2 accuracy at installation and at least every six months with a calibrated external instrument, and record recovery time after door opening. Do not overload shelves, because air circulation is needed for uniformity. Handle spills immediately, use only compatible disinfectants, and follow the manufacturer's decontamination procedure before servicing. Keep a log of cleaning, calibration and decontamination events so that culture problems can be traced.

How do I select the right Water-Jacketed CO2 Incubator?

Select a water-jacketed incubator when culture stability during power events and heavy door use matters more than weight and routine maintenance. Specify chamber volume, jacket refill interval, CO2 sensor type, contamination control features and the data logging options offered by the supplier.

How does it compare with other CO2 Incubators variants?

Choose the chamber type first. Water-jacketed incubators hold temperature most stably through power interruptions and suit laboratories with frequent door openings, while air-jacketed and direct-heat models warm up faster, are lighter and need less maintenance. Then consider contamination control: copper interior surfaces, HEPA filtration of the air circuit and high-temperature or vaporised hydrogen peroxide decontamination cycles reduce losses in busy laboratories. Check CO2 and temperature accuracy and uniformity, recovery time after door opening, humidity control, and whether oxygen control is needed for stem cell or hypoxia work. Review alarm functions, data logging, access control and remote monitoring if the incubator holds irreplaceable cultures or is part of a regulated process. Confirm stackability, shelf adjustability and available chamber volumes before ordering.

Full specifications

Full specifications
Chamber volume150–300 L (model dependent)
Temperature rangeambient +5 to 50 °C, set at 37 °C
Temperature uniformitywithin ±0.2 °C at 37 °C
Jacket volumeapprox. 20–40 L distilled water
CO2 range0–20%, controlled at 5%
CO2 accuracywithin ±0.1–0.3% (infrared sensor)
Humidityabove 90% relative humidity
Shelves4–6 adjustable shelves
Weightapprox. 120–200 kg when filled
Dimensions (W x D x H)approx. 700 x 750 x 1,100 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Stem cell and primary cell culture
  • Vaccine production and virus culture
  • Clinical and cytogenetic laboratories
  • Long-term culture of irreplaceable lines

Key features

  • Sealed water jacket buffering temperature during power interruptions
  • Temperature uniformity within about ±0.2 °C
  • Fast recovery once the door is closed
  • Infrared CO2 sensor with humidity-independent measurement
  • Copper-lined or antimicrobial interior options
  • Larger chamber volumes for high-density workloads

Frequently asked questions about Water-Jacketed CO2 Incubator

The large thermal mass means chamber temperature falls only slowly during a power cut, often by less than 1 °C in the first 30 minutes, giving time to restore power or move cultures. Air-jacketed units cool faster.

Related models

All CO2 Incubators

Request a quotation for the Water-Jacketed CO2 Incubator

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote