Air-Jacketed CO2 Incubator
气套式 CO2 培养箱
- SKU CON-0001
- CO2 Incubators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Chamber volume | 50–200 L (model dependent) |
|---|---|
| Temperature range | ambient +5 to 50 °C, set at 37 °C |
| Temperature uniformity | within ±0.3 °C at 37 °C |
| CO2 range | 0–20%, controlled at 5% |
| CO2 accuracy | within ±0.1–0.3% (infrared sensor) |
| Humidity | above 90% relative humidity with water pan |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1
What is the Air-Jacketed CO2 Incubator?
An air-jacketed CO2 incubator surrounds the chamber with heated air to hold 37 °C and 5% CO2, warming quickly and recovering rapidly after door openings. It suits routine cell culture in laboratories that value easy maintenance and light weight.
What is the Air-Jacketed CO2 Incubator?
An air-jacketed CO2 incubator surrounds the chamber with heated air to hold 37 °C and 5% CO2, warming quickly and recovering rapidly after door openings. It suits routine cell culture in laboratories that value easy maintenance and light weight.
Overview
Heating elements circulate warm air around the inner chamber, and a fan distributes it to reduce temperature gradients. Infrared CO2 sensing holds the gas within a narrow band regardless of humidity, and a water pan maintains relative humidity above 90%. Chamber volumes are commonly 50–200 L with three to five adjustable shelves, so typical workloads of flasks, dishes and multi-well plates fit comfortably. Recovery times after a one-minute door opening are usually 5–10 minutes for temperature and CO2, which is adequate for routine work with frequent access. Interior surfaces are usually stainless steel, often with copper-lined versions available for contamination control, and the outer cabinet is lighter than a water-jacketed equivalent, making relocation feasible.
How does it work?
Cells in culture cannot regulate their own environment, so the incubator supplies what the medium cannot. Temperature is held at 37 °C by a water jacket, an air jacket or direct heating elements around the chamber, with a PID controller and an over-temperature cut-out. Carbon dioxide is measured by an infrared or thermal conductivity sensor and injected from a supply cylinder to maintain 5% CO2, which keeps bicarbonate-buffered medium at physiological pH. A water pan or humidity injection keeps relative humidity above 90%, preventing evaporation that would concentrate salts and osmolytes and change the pH set point. Copper-lined or antimicrobial interior panels and HEPA filters reduce contamination risk, and an inner glass door limits gas exchange when the outer door is opened. Some models add nitrogen to control oxygen for hypoxic culture.
What are the key features?
- Heated air jacket with fan-circulated uniform temperature
- Infrared CO2 sensor unaffected by chamber humidity
- Chamber volumes of 50–200 L with adjustable shelves
- Water pan maintaining relative humidity above 90%
- Temperature and CO2 recovery within about 5–10 minutes
- Lightweight cabinet with optional copper-lined interior
What are the technical specifications?
A typical air-jacketed co2 incubator configuration offers chamber volume of 50–200 L (model dependent), temperature range of ambient +5 to 50 °C, set at 37 °C, temperature uniformity of within ±0.3 °C at 37 °C, CO2 range of 0–20%, controlled at 5%, CO2 accuracy of within ±0.1–0.3% (infrared sensor) and humidity of above 90% relative humidity with water pan. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Air-Jacketed CO2 Incubator is used in routine adherent cell line maintenance, multi-well plate and flask culture, teaching and diagnostic culture work and primary cell short-term culture. Across the wider CO2 Incubators class, laboratories also deploy it for routine mammalian cell line culture, stem cell and primary cell maintenance and vaccine and recombinant protein production.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, EN 12469, ISO 14644-1 and USP <1046>. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the incubator on a level surface away from direct sunlight, heat sources and draughts, leaving clearance for the gas connection and ventilation. Fill the humidity pan with sterile distilled water and change it weekly, since stagnant water is a common contamination source; some models use humidity injection that avoids standing water. Verify temperature and CO2 accuracy at installation and at least every six months with a calibrated external instrument, and record recovery time after door opening. Do not overload shelves, because air circulation is needed for uniformity. Handle spills immediately, use only compatible disinfectants, and follow the manufacturer's decontamination procedure before servicing. Keep a log of cleaning, calibration and decontamination events so that culture problems can be traced.
How do I select the right Air-Jacketed CO2 Incubator?
Select an air-jacketed incubator for routine culture where quick warm-up, light weight and low maintenance are priorities. Specify chamber volume, shelf count, CO2 sensor type, whether a copper-lined interior is needed and the alarm and data logging features offered.
How does it compare with other CO2 Incubators variants?
Choose the chamber type first. Water-jacketed incubators hold temperature most stably through power interruptions and suit laboratories with frequent door openings, while air-jacketed and direct-heat models warm up faster, are lighter and need less maintenance. Then consider contamination control: copper interior surfaces, HEPA filtration of the air circuit and high-temperature or vaporised hydrogen peroxide decontamination cycles reduce losses in busy laboratories. Check CO2 and temperature accuracy and uniformity, recovery time after door opening, humidity control, and whether oxygen control is needed for stem cell or hypoxia work. Review alarm functions, data logging, access control and remote monitoring if the incubator holds irreplaceable cultures or is part of a regulated process. Confirm stackability, shelf adjustability and available chamber volumes before ordering.
Full specifications
| Chamber volume | 50–200 L (model dependent) |
|---|---|
| Temperature range | ambient +5 to 50 °C, set at 37 °C |
| Temperature uniformity | within ±0.3 °C at 37 °C |
| CO2 range | 0–20%, controlled at 5% |
| CO2 accuracy | within ±0.1–0.3% (infrared sensor) |
| Humidity | above 90% relative humidity with water pan |
| Shelves | 3–5 adjustable stainless steel shelves |
| Interior | Stainless steel, copper-lined option |
| Recovery time | approx. 5–10 min after 1 min door opening |
| Dimensions (W x D x H) | approx. 600 x 650 x 900 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine adherent cell line maintenance
- Multi-well plate and flask culture
- Teaching and diagnostic culture work
- Primary cell short-term culture
Key features
- Heated air jacket with fan-circulated uniform temperature
- Infrared CO2 sensor unaffected by chamber humidity
- Chamber volumes of 50–200 L with adjustable shelves
- Water pan maintaining relative humidity above 90%
- Temperature and CO2 recovery within about 5–10 minutes
- Lightweight cabinet with optional copper-lined interior
Frequently asked questions about Air-Jacketed CO2 Incubator
Typically 5–10 minutes to return to 37 °C and 5% CO2 after a one-minute opening, which is acceptable for routine work. Frequent long openings cause larger excursions, so an inner glass door is useful.
Yes for most laboratories. It is not affected by chamber humidity or temperature the way thermal conductivity sensors are, so concentration stays closer to the set point and needs less frequent recalibration.
Most models in this class are stackable in pairs with a stacking kit, which saves floor space. Confirm that the lower unit can support the weight and that the gas connections remain accessible.
Water-jacketed chambers hold temperature more stably during power cuts and heavy door use, but are heavier and need more maintenance. Air-jacketed and direct-heat units warm up faster, recover quickly and are easier to move, which suits most routine laboratories.
Without high humidity, medium evaporates and concentrates salts and proteins, raising osmolarity and shifting pH. This changes growth rates and can make results from long experiments inconsistent, especially in small-volume or multi-well formats.
Infrared sensors typically hold CO2 within ±0.1–0.3% of the set point and are unaffected by humidity, while thermal conductivity sensors are cheaper but sensitive to moisture. Accuracy should be verified with a calibrated analyser at least twice a year.
Related models