Vertical Laminar Flow Cell Culture Hood
垂直层流细胞培养超净台
- SKU CCH-0004
- Cell Culture Hoods
- CE (to be confirmed)
- ISO 14644-1 cleanliness verification (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working width | 0.9–1.8 m |
|---|---|
| Airflow velocity | approx. 0.35–0.55 m/s |
| Filtration | HEPA, 99.99% at 0.3 µm |
| Cleanliness | ISO Class 5 in the work zone |
| Airflow direction | Vertical, ceiling to work surface |
| Operator protection | None; not for hazardous material |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 12469, NSF/ANSI 49, ISO 14644-1
What is the Vertical Laminar Flow Cell Culture Hood?
A vertical laminar flow hood delivers HEPA-filtered air downward onto the work surface from the top of the enclosure, protecting cultures while keeping the operator's hands clear and reducing draughts across open vessels.
What is the Vertical Laminar Flow Cell Culture Hood?
A vertical laminar flow hood delivers HEPA-filtered air downward onto the work surface from the top of the enclosure, protecting cultures while keeping the operator's hands clear and reducing draughts across open vessels.
Overview
Filtered air passes through a ceiling HEPA panel and flows vertically down across the work zone, then exits through grilles at the front and rear base. Because the airflow is perpendicular to the work surface, it does not blow directly into open flask mouths from the side, and objects placed in the stream create fewer wake effects than in a horizontal bench. The design also allows a partial front screen or hinged visor, which limits room air ingress without restricting movement excessively. Vertical benches are often used for tissue culture and for assembling sterile components where a gentle, even downflow is preferred. As with horizontal benches, they protect the sample rather than the operator and must not be used with hazardous aerosols.
How does it work?
Sterile work depends on supplying particle-free air and preventing entry of contaminants from the room. Room air is drawn through a HEPA filter that removes 99.99% of particles at 0.3 µm, and the filtered air flows in a laminar stream over the work surface. In a clean bench, air moves horizontally or vertically across the surface and out toward the operator, protecting the sample only. In a class II biological safety cabinet, air enters a front grille, passes through the supply filter to create a sterile downflow curtain, and is then split so that part recirculates and part is exhausted through a second HEPA filter, protecting both product and operator. A front air barrier prevents room air from entering the work zone when arms reach in, and airflow velocities are designed to balance containment against the risk of disturbing cultures.
What are the key features?
- Ceiling HEPA panel with vertical downflow over the work zone
- Front and rear base grilles for balanced return airflow
- Partial visor or screen limiting room air ingress
- Even airflow across open vessels with fewer wake effects
- Stainless steel work surface with removable tray
- Optional UV lamp and low-noise blower
What are the technical specifications?
A typical vertical laminar flow cell culture hood configuration offers working width of 0.9–1.8 m, airflow velocity of approx. 0.35–0.55 m/s, filtration of HEPA, 99.99% at 0.3 µm, cleanliness of ISO Class 5 in the work zone, airflow direction of Vertical, ceiling to work surface and operator protection of None; not for hazardous material. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Vertical Laminar Flow Cell Culture Hood is used in tissue culture in open flasks and dishes, sterile component assembly, media aliquoting and bottle filling and plant and insect cell culture. Across the wider Cell Culture Hoods class, laboratories also deploy it for aseptic cell culture and subculture, primary cell and stem cell handling and media preparation and bottle filling.
Which standards and certifications apply?
Relevant standards and methods include EN 12469, NSF/ANSI 49, ISO 14644-1, IEC 61010-1, IEC 61326-1 and USP <1046>. Certification candidates for this model are CE, ISO 14644-1 cleanliness verification and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
A new or relocated cabinet must be certified after installation and yearly thereafter, with filter integrity, downflow velocity, inflow velocity and airflow visualisation recorded against EN 12469 or NSF/ANSI 49. Avoid placing the cabinet near doors, windows, air supply diffusers or high-traffic routes, because draughts disturb the air barrier. Clean the work surface before and after use with 70% ethanol or a compatible disinfectant, and run the blower for several minutes before starting work. Do not block the front or rear grilles with equipment, since that alters airflow and can break containment. UV lamps are a supplement, not a substitute, for cleaning, and should be replaced when intensity falls below specification. Record certification, cleaning and maintenance in a log for audit purposes.
How do I select the right Vertical Laminar Flow Cell Culture Hood?
Select a vertical flow hood when you want sample protection with reduced draughts over open vessels and a partial front screen. Specify working width, airflow velocity, visor type, filter access and confirm that no hazardous aerosols are generated in normal use.
How does it compare with other Cell Culture Hoods variants?
Decide first whether the operator needs protection. Any work with human or animal cells, infectious material or genetically modified organisms requires a class II cabinet, and a type A2 model covers most cell culture needs when recirculating exhaust is acceptable. Type B2 cabinets exhaust all air to the outside and are used with volatile chemicals or radionuclides that must not recirculate. Clean benches are appropriate only for non-hazardous cultures where sample protection alone is sufficient. Then check working dimensions, airflow velocities and alarms, filter integrity test points, interior material, UV lamp, and whether an electrical outlet panel and gas or vacuum service are needed inside the work zone. Confirm that the cabinet will be certified after installation in your laboratory and that the annual certification service is available locally.
Full specifications
| Working width | 0.9–1.8 m |
|---|---|
| Airflow velocity | approx. 0.35–0.55 m/s |
| Filtration | HEPA, 99.99% at 0.3 µm |
| Cleanliness | ISO Class 5 in the work zone |
| Airflow direction | Vertical, ceiling to work surface |
| Operator protection | None; not for hazardous material |
| Noise level | below 63 dB(A) |
| Visor | Fixed partial screen or hinged visor |
| Illumination | above 800 lux |
| Dimensions (W x D x H) | approx. 1,200 x 800 x 1,300 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Tissue culture in open flasks and dishes
- Sterile component assembly
- Media aliquoting and bottle filling
- Plant and insect cell culture
Key features
- Ceiling HEPA panel with vertical downflow over the work zone
- Front and rear base grilles for balanced return airflow
- Partial visor or screen limiting room air ingress
- Even airflow across open vessels with fewer wake effects
- Stainless steel work surface with removable tray
- Optional UV lamp and low-noise blower
Frequently asked questions about Vertical Laminar Flow Cell Culture Hood
Downward airflow is less likely to blow directly into open containers or create turbulent wakes behind equipment, which improves protection of open cultures. A partial front screen also reduces room air ingress without restricting access greatly.
No. The operator is downstream of the work zone in the sense that aerosols are not contained, and there is no air barrier at the front. Hazardous work requires a class II biological safety cabinet instead.
Keep the work area uncluttered, place items toward the sides, and avoid stacking, which creates turbulence. Work at least 10 cm inside the front edge so that the filtered air reaches samples before any room air can.
Use a class II biosafety cabinet whenever cultures may contain human or animal cells, infectious agents or genetically modified material, because it protects the operator as well as the sample. A clean bench is acceptable only for non-hazardous cultures needing sample protection.
At installation, after any relocation or major repair, and at least annually thereafter. Certification covers HEPA filter integrity, downflow and inflow velocities, and airflow visualisation against EN 12469 or NSF/ANSI 49, with results recorded.
Away from doors, windows, air conditioning diffusers and busy walkways, because cross-draughts disturb the air barrier and can draw contaminants into the work zone. Confirm suitable bench height and clearance above the cabinet for exhaust and service access.