Skip to main content
Lab Manufacturers China
Benchtop Cell Culture Enclosure with UV Sterilisation — product photo

Benchtop Cell Culture Enclosure with UV Sterilisation

台式细胞培养无菌操作箱

  • SKU CCH-0005
  • Cell Culture Hoods
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Working width0.6–0.9 m
FiltrationHEPA, 99.99% at 0.3 µm
Airflow velocityapprox. 0.3–0.45 m/s
UV lamp254 nm, interlocked with front panel
CleanlinessISO Class 5 in the work zone (typical)
Operator protectionNone; sample protection only
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 12469, NSF/ANSI 49, ISO 14644-1

What is the Benchtop Cell Culture Enclosure with UV Sterilisation?

A benchtop cell culture enclosure creates a small sterile workspace with HEPA-filtered air and UV sterilisation, giving a low-cost, portable solution for occasional culture work where a full cabinet is not available.

What is the Benchtop Cell Culture Enclosure with UV Sterilisation?

A benchtop cell culture enclosure creates a small sterile workspace with HEPA-filtered air and UV sterilisation, giving a low-cost, portable solution for occasional culture work where a full cabinet is not available.

Overview

The enclosure is a compact box with a filtered air supply, a hinged or sliding front panel and UV lamps for surface sterilisation between sessions. Air is drawn through a HEPA filter and delivered gently over the work surface, maintaining lower particle counts than the surrounding room. Working width is typically 0.6–0.9 m, enough for a few flasks, a pipette and a small bottle, and the unit can be moved between benches or stored when not in use. Ultraviolet lamps inactivate organisms on exposed surfaces but do not penetrate dust, liquid films or shaded areas, so manual cleaning remains essential. These enclosures provide sample protection only and are unsuitable for infectious, toxic or allergenic material or for work requiring documented operator protection.

How does it work?

Sterile work depends on supplying particle-free air and preventing entry of contaminants from the room. Room air is drawn through a HEPA filter that removes 99.99% of particles at 0.3 µm, and the filtered air flows in a laminar stream over the work surface. In a clean bench, air moves horizontally or vertically across the surface and out toward the operator, protecting the sample only. In a class II biological safety cabinet, air enters a front grille, passes through the supply filter to create a sterile downflow curtain, and is then split so that part recirculates and part is exhausted through a second HEPA filter, protecting both product and operator. A front air barrier prevents room air from entering the work zone when arms reach in, and airflow velocities are designed to balance containment against the risk of disturbing cultures.

What are the key features?

  • Compact enclosure with HEPA-filtered air supply
  • UV lamps for surface sterilisation between sessions
  • Working width of 0.6–0.9 m for small batch work
  • Portable design that can be moved between benches
  • Transparent front panel for visibility during work
  • Interlocked UV lamp to prevent exposure during use

What are the technical specifications?

A typical benchtop cell culture enclosure with uv sterilisation configuration offers working width of 0.6–0.9 m, filtration of HEPA, 99.99% at 0.3 µm, airflow velocity of approx. 0.3–0.45 m/s, UV lamp of 254 nm, interlocked with front panel, cleanliness of ISO Class 5 in the work zone (typical) and operator protection of None; sample protection only. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop Cell Culture Enclosure with UV Sterilisation is used in occasional cell culture in small laboratories, plant tissue culture and seed germination work, teaching demonstrations of aseptic technique and small-batch media preparation. Across the wider Cell Culture Hoods class, laboratories also deploy it for aseptic cell culture and subculture, primary cell and stem cell handling and media preparation and bottle filling.

Which standards and certifications apply?

Relevant standards and methods include EN 12469, NSF/ANSI 49, ISO 14644-1, IEC 61010-1, IEC 61326-1 and USP <1046>. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

A new or relocated cabinet must be certified after installation and yearly thereafter, with filter integrity, downflow velocity, inflow velocity and airflow visualisation recorded against EN 12469 or NSF/ANSI 49. Avoid placing the cabinet near doors, windows, air supply diffusers or high-traffic routes, because draughts disturb the air barrier. Clean the work surface before and after use with 70% ethanol or a compatible disinfectant, and run the blower for several minutes before starting work. Do not block the front or rear grilles with equipment, since that alters airflow and can break containment. UV lamps are a supplement, not a substitute, for cleaning, and should be replaced when intensity falls below specification. Record certification, cleaning and maintenance in a log for audit purposes.

How do I select the right Benchtop Cell Culture Enclosure with UV Sterilisation?

Select a compact enclosure for small-scale, non-hazardous culture work where space and budget are limited and a certified cabinet is not justified. Specify working width, filter type, UV interlock, portability and confirm the airflow velocity with a test certificate.

How does it compare with other Cell Culture Hoods variants?

Decide first whether the operator needs protection. Any work with human or animal cells, infectious material or genetically modified organisms requires a class II cabinet, and a type A2 model covers most cell culture needs when recirculating exhaust is acceptable. Type B2 cabinets exhaust all air to the outside and are used with volatile chemicals or radionuclides that must not recirculate. Clean benches are appropriate only for non-hazardous cultures where sample protection alone is sufficient. Then check working dimensions, airflow velocities and alarms, filter integrity test points, interior material, UV lamp, and whether an electrical outlet panel and gas or vacuum service are needed inside the work zone. Confirm that the cabinet will be certified after installation in your laboratory and that the annual certification service is available locally.

Full specifications

Full specifications
Working width0.6–0.9 m
FiltrationHEPA, 99.99% at 0.3 µm
Airflow velocityapprox. 0.3–0.45 m/s
UV lamp254 nm, interlocked with front panel
CleanlinessISO Class 5 in the work zone (typical)
Operator protectionNone; sample protection only
Noise levelbelow 60 dB(A)
Power supply100–240 V, approx. 100 W
PortabilityBench-top unit, approx. 15–30 kg
Dimensions (W x D x H)approx. 700 x 500 x 500 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Occasional cell culture in small laboratories
  • Plant tissue culture and seed germination work
  • Teaching demonstrations of aseptic technique
  • Small-batch media preparation

Key features

  • Compact enclosure with HEPA-filtered air supply
  • UV lamps for surface sterilisation between sessions
  • Working width of 0.6–0.9 m for small batch work
  • Portable design that can be moved between benches
  • Transparent front panel for visibility during work
  • Interlocked UV lamp to prevent exposure during use

Frequently asked questions about Benchtop Cell Culture Enclosure with UV Sterilisation

No. It filters air for sample protection but has no air barrier and no exhaust filtration, so it does not protect the operator. Infectious, toxic or allergenic material must be handled in a certified class II cabinet.

Request a quotation for the Benchtop Cell Culture Enclosure with UV Sterilisation

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote