Online Contacting Conductivity Analyzer for Pure Water
纯水在线接触式电导率分析仪
- SKU COM-0004
- Conductivity Meters
- CE (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0.055–200 µS/cm |
|---|---|
| Resistivity range | 0.005–18.2 MΩ·cm |
| Accuracy | ±1% of reading |
| Cell constant | 0.01–0.1 cm⁻¹ |
| Temperature sensor | Pt1000 |
| Process temperature | 0–100 °C (up to 130 °C optional) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <645>, Ph. Eur. 2.2.38, ASTM D1125
What is the Online Contacting Conductivity Analyzer for Pure Water?
An online contacting conductivity analyzer continuously measures low-range conductivity or resistivity in purified and ultrapure water systems using a flow-through two-electrode cell and a transmitter. It supports reverse osmosis, deionization and pharmaceutical water loop monitoring with alarms and 4–20 mA outputs.
What is the Online Contacting Conductivity Analyzer for Pure Water?
An online contacting conductivity analyzer continuously measures low-range conductivity or resistivity in purified and ultrapure water systems using a flow-through two-electrode cell and a transmitter. It supports reverse osmosis, deionization and pharmaceutical water loop monitoring with alarms and 4–20 mA outputs.
Overview
This variant is built for continuous monitoring of water with conductivity below about 200 microsiemens per centimeter. A stainless steel two-electrode or four-electrode cell with constants of 0.01 to 0.1 per centimeter sits in a flow-through housing with an integrated Pt1000 temperature sensor. The transmitter compensates for temperature using the nonlinear pure-water model and can display conductivity in microsiemens per centimeter or resistivity in megohm-centimeters, with ranges extending down to 0.055 microsiemens per centimeter at 25 degrees Celsius. Outputs include 4–20 mA, relays for alarm and control, and Modbus or HART. Pharmaceutical versions include uncompensated conductivity for USP <645> stage 1 checks and calibration records. Installation must avoid air entrainment and stagnant flow, since carbon dioxide absorption and bubbles produce errors. Typical accuracy is ±1 percent of reading.
How does it work?
Conductivity is measured by applying an alternating voltage across two or four electrodes of a cell with known geometry and measuring the resulting current. The conductance, in siemens, multiplied by the cell constant (the ratio of electrode spacing to area, in reciprocal centimeters) gives conductivity in microsiemens or millisiemens per centimeter. Alternating current at frequencies from hundreds of hertz to several kilohertz avoids electrode polarization. Conductivity rises by about 2 percent per degree Celsius, so meters compensate to a reference temperature, usually 25 degrees Celsius, using a linear coefficient or a nonlinear function for natural or ultrapure water. Cells with constants of 0.01 to 0.1 per centimeter are used for pure water, 1 per centimeter for general work and 10 per centimeter for concentrated solutions. Inductive cells use two toroidal coils and have no exposed electrodes, which suits aggressive or fouling media. TDS is estimated by multiplying conductivity by a factor of about 0.5 to 0.7.
What are the key features?
- Stainless steel flow-through cell with constants of 0.01 to 0.1 cm⁻¹ for low-range water
- Nonlinear pure-water temperature compensation and Pt1000 sensing
- Display in µS/cm or MΩ·cm with limits down to 0.055 µS/cm
- 4–20 mA, relay and Modbus or HART outputs for control rooms
- Uncompensated conductivity mode and calibration records for pharmaceutical use
- Alarm setpoints for RO, EDI and loop breakthrough detection
What are the technical specifications?
A typical online contacting conductivity analyzer for pure water configuration offers measuring range of 0.055–200 µS/cm, resistivity range of 0.005–18.2 MΩ·cm, accuracy of ±1% of reading, cell constant of 0.01–0.1 cm⁻¹, temperature sensor of Pt1000 and process temperature of 0–100 °C (up to 130 °C optional). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Online Contacting Conductivity Analyzer for Pure Water is used in reverse osmosis and EDI monitoring, pharmaceutical purified water loops, power plant steam and condensate, semiconductor rinse water and laboratory water purification systems. Across the wider Conductivity Meters class, laboratories also deploy it for pharmaceutical purified water testing, drinking and wastewater monitoring and boiler and cooling water control.
Which standards and certifications apply?
Relevant standards and methods include USP <645>, Ph. Eur. 2.2.38, ASTM D1125, ASTM D5391, ISO 7888, OIML R 68, IEC 60746-3 and GB/T 6908. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate with traceable potassium chloride standards close to the sample range, for example 84, 1413 or 12880 microsiemens per centimeter, at a controlled temperature. For ultrapure water, measure in a flow-through cell to avoid absorption of carbon dioxide, which raises conductivity within minutes. Rinse the cell with sample before measuring and store it dry or in deionized water as recommended. Platinum black coating should be protected from contamination and re-platinized when needed. Verify the cell constant periodically. Pharmaceutical laboratories should follow USP <645> or Ph. Eur. 2.2.38 staged testing and keep calibration and verification records. Keep cables away from power lines to avoid interference and ensure samples are not contaminated by handling.
How do I select the right Online Contacting Conductivity Analyzer for Pure Water?
Choose this variant for continuous monitoring of purified water lines, RO permeate and ultrapure systems. For dirty or conductive process streams use an inductive sensor instead. In an RFQ specify cell constant, range, process connection, temperature and pressure, compliance needs and communication protocol.
How does it compare with other Conductivity Meters variants?
Start with the conductivity range of your samples, because the cell constant must match it: use 0.01 to 0.1 per centimeter for ultrapure water, 1 per centimeter for drinking water and most laboratory work, and 10 per centimeter for brines and concentrated solutions. Then choose the format. Benchtop meters give the best accuracy and GLP features, portable meters suit field sampling and plant rounds, pen testers suit screening, and online analyzers give continuous monitoring with relay and 4–20 mA outputs. Pharmaceutical water testing requires a meter and cell that support USP <645> with temperature compensation disabled and calibration traceable to standards. For fouling or corrosive media consider inductive sensors. Check the accuracy specification, temperature compensation options, cell material and the cost of calibration standards.
Full specifications
| Measuring range | 0.055–200 µS/cm |
|---|---|
| Resistivity range | 0.005–18.2 MΩ·cm |
| Accuracy | ±1% of reading |
| Cell constant | 0.01–0.1 cm⁻¹ |
| Temperature sensor | Pt1000 |
| Process temperature | 0–100 °C (up to 130 °C optional) |
| Process pressure | up to 10 bar |
| Analog output | 4–20 mA (1–2 channels) |
| Digital interface | Modbus RTU / HART |
| Wetted materials | 316L stainless steel, PEEK or PVDF |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Reverse osmosis and EDI monitoring
- Pharmaceutical purified water loops
- Power plant steam and condensate
- Semiconductor rinse water
- Laboratory water purification systems
Key features
- Stainless steel flow-through cell with constants of 0.01 to 0.1 cm⁻¹ for low-range water
- Nonlinear pure-water temperature compensation and Pt1000 sensing
- Display in µS/cm or MΩ·cm with limits down to 0.055 µS/cm
- 4–20 mA, relay and Modbus or HART outputs for control rooms
- Uncompensated conductivity mode and calibration records for pharmaceutical use
- Alarm setpoints for RO, EDI and loop breakthrough detection
Frequently asked questions about Online Contacting Conductivity Analyzer for Pure Water
A low cell constant such as 0.01 per centimeter increases the measured current for very low conductivity, giving better resolution and stability. Using a cell constant of 1 would produce currents too small to measure accurately in ultrapure water.
Versions with uncompensated conductivity, a verifiable cell constant and appropriate calibration records can support stage 1 testing of USP <645>. The laboratory remains responsible for validation, calibration with traceable standards and procedures, which must be confirmed for the specific model.
Common errors are air bubbles, stagnant sections, long cable runs that add capacitance and incorrect cell constant entries. Mount the cell in a vertical flow path with sufficient velocity and keep it close to the point of use.
It measures how well a solution conducts electricity, reported in microsiemens or millisiemens per centimeter. Because dissolved ions carry the current, conductivity indicates total ionic content and is used for water purity, salinity and TDS estimation.
TDS meters measure conductivity and multiply it by a conversion factor, commonly 0.5 to 0.7, to estimate dissolved solids in mg/L. The factor depends on the ion mix, so the result is an estimate unless verified against gravimetric TDS.
Choose a cell constant that places the sample in the middle of the cell range: 0.01 to 0.1 per centimeter for ultrapure water below 20 microsiemens per centimeter, 1 per centimeter for 10 to 20,000 microsiemens per centimeter, and 10 per centimeter for higher values.