Portable Conductivity Meter
便携式电导率仪
- SKU COM-0002
- Conductivity Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Conductivity range | 0–200 mS/cm |
|---|---|
| Accuracy | ±0.5–1% of reading |
| Resolution | 0.01 µS/cm (lowest range) |
| Salinity range | 0–70 PSU |
| TDS range | 0–100 g/L |
| Temperature range | −5 to 105 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <645>, Ph. Eur. 2.2.38, ASTM D1125
What is the Portable Conductivity Meter?
A portable conductivity meter is a rugged battery-powered handheld instrument with IP-rated housing, automatic ranging and temperature compensation. It is used for field sampling, environmental surveys, aquaculture and plant rounds where conductivity, salinity or TDS must be read at the sampling point.
What is the Portable Conductivity Meter?
A portable conductivity meter is a rugged battery-powered handheld instrument with IP-rated housing, automatic ranging and temperature compensation. It is used for field sampling, environmental surveys, aquaculture and plant rounds where conductivity, salinity or TDS must be read at the sampling point.
Overview
Portable meters use an IP65 to IP67 housing, a backlit display and battery operation for 100 to 500 hours. The sensor is typically a four-electrode graphite or stainless steel probe on a cable of 1 to 100 m with integrated temperature sensing, which allows use in rivers, boreholes and tanks. Ranges commonly span 0 to 200 millisiemens per centimeter with automatic ranging and accuracy of ±0.5 to ±1 percent of reading. The display shows conductivity, salinity, TDS and specific conductance at 25 degrees Celsius. Calibration uses one or two standards and stores the cell constant. Data logging of hundreds to thousands of samples, with time and optional GPS, and Bluetooth or USB transfer help with environmental reporting. Multiparameter versions add pH, dissolved oxygen and ORP. Probes are designed to resist fouling and to be rinsed easily.
How does it work?
Conductivity is measured by applying an alternating voltage across two or four electrodes of a cell with known geometry and measuring the resulting current. The conductance, in siemens, multiplied by the cell constant (the ratio of electrode spacing to area, in reciprocal centimeters) gives conductivity in microsiemens or millisiemens per centimeter. Alternating current at frequencies from hundreds of hertz to several kilohertz avoids electrode polarization. Conductivity rises by about 2 percent per degree Celsius, so meters compensate to a reference temperature, usually 25 degrees Celsius, using a linear coefficient or a nonlinear function for natural or ultrapure water. Cells with constants of 0.01 to 0.1 per centimeter are used for pure water, 1 per centimeter for general work and 10 per centimeter for concentrated solutions. Inductive cells use two toroidal coils and have no exposed electrodes, which suits aggressive or fouling media. TDS is estimated by multiplying conductivity by a factor of about 0.5 to 0.7.
What are the key features?
- IP67 rugged housing with backlit display for field use
- Four-electrode probe with integrated temperature sensor and cable up to 100 m
- Automatic ranging from 0 to 200 mS/cm with specific conductance at 25 °C
- Readout of salinity, TDS and resistivity alongside conductivity
- Data logging with time stamp and optional GPS position
- Bluetooth or USB transfer to phones, tablets or computers
What are the technical specifications?
A typical portable conductivity meter configuration offers conductivity range of 0–200 mS/cm, accuracy of ±0.5–1% of reading, resolution of 0.01 µS/cm (lowest range), salinity range of 0–70 PSU, TDS range of 0–100 g/L and temperature range of −5 to 105 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Portable Conductivity Meter is used in river and lake surveys, groundwater and borehole monitoring, aquaculture salinity control, irrigation and soil extracts and industrial plant rounds. Across the wider Conductivity Meters class, laboratories also deploy it for pharmaceutical purified water testing, drinking and wastewater monitoring and boiler and cooling water control.
Which standards and certifications apply?
Relevant standards and methods include USP <645>, Ph. Eur. 2.2.38, ASTM D1125, ASTM D5391, ISO 7888, OIML R 68, IEC 60746-3 and GB/T 6908. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate with traceable potassium chloride standards close to the sample range, for example 84, 1413 or 12880 microsiemens per centimeter, at a controlled temperature. For ultrapure water, measure in a flow-through cell to avoid absorption of carbon dioxide, which raises conductivity within minutes. Rinse the cell with sample before measuring and store it dry or in deionized water as recommended. Platinum black coating should be protected from contamination and re-platinized when needed. Verify the cell constant periodically. Pharmaceutical laboratories should follow USP <645> or Ph. Eur. 2.2.38 staged testing and keep calibration and verification records. Keep cables away from power lines to avoid interference and ensure samples are not contaminated by handling.
How do I select the right Portable Conductivity Meter?
Choose a portable meter for field conductivity, salinity and TDS readings. If ultrapure water or pharmacopoeial compliance is needed, use a benchtop meter or online analyzer. In an RFQ specify range, cable length, ingress rating, logging capacity, wireless and any extra parameters.
How does it compare with other Conductivity Meters variants?
Start with the conductivity range of your samples, because the cell constant must match it: use 0.01 to 0.1 per centimeter for ultrapure water, 1 per centimeter for drinking water and most laboratory work, and 10 per centimeter for brines and concentrated solutions. Then choose the format. Benchtop meters give the best accuracy and GLP features, portable meters suit field sampling and plant rounds, pen testers suit screening, and online analyzers give continuous monitoring with relay and 4–20 mA outputs. Pharmaceutical water testing requires a meter and cell that support USP <645> with temperature compensation disabled and calibration traceable to standards. For fouling or corrosive media consider inductive sensors. Check the accuracy specification, temperature compensation options, cell material and the cost of calibration standards.
Full specifications
| Conductivity range | 0–200 mS/cm |
|---|---|
| Accuracy | ±0.5–1% of reading |
| Resolution | 0.01 µS/cm (lowest range) |
| Salinity range | 0–70 PSU |
| TDS range | 0–100 g/L |
| Temperature range | −5 to 105 °C |
| Ingress protection | IP65–IP67 |
| Battery life | 100–500 h |
| Cable length | 1–100 m |
| Data memory | 500–5000 records |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- River and lake surveys
- Groundwater and borehole monitoring
- Aquaculture salinity control
- Irrigation and soil extracts
- Industrial plant rounds
Key features
- IP67 rugged housing with backlit display for field use
- Four-electrode probe with integrated temperature sensor and cable up to 100 m
- Automatic ranging from 0 to 200 mS/cm with specific conductance at 25 °C
- Readout of salinity, TDS and resistivity alongside conductivity
- Data logging with time stamp and optional GPS position
- Bluetooth or USB transfer to phones, tablets or computers
Frequently asked questions about Portable Conductivity Meter
Specific conductance is conductivity corrected to a reference temperature, usually 25 degrees Celsius, so that measurements taken at different temperatures can be compared. Portable meters display it automatically when temperature compensation is enabled.
Yes, provided the range covers about 50 to 55 millisiemens per centimeter and the salinity conversion follows the practical salinity scale. Rinse the probe with deionized water after use to avoid salt buildup and calibrate with a suitable high-range standard.
Check calibration before each field campaign or at least weekly during routine use with a standard near the expected conductivity. Recalibrate if the reading deviates by more than the method tolerance, typically 1 to 2 percent.
It measures how well a solution conducts electricity, reported in microsiemens or millisiemens per centimeter. Because dissolved ions carry the current, conductivity indicates total ionic content and is used for water purity, salinity and TDS estimation.
TDS meters measure conductivity and multiply it by a conversion factor, commonly 0.5 to 0.7, to estimate dissolved solids in mg/L. The factor depends on the ion mix, so the result is an estimate unless verified against gravimetric TDS.
Choose a cell constant that places the sample in the middle of the cell range: 0.01 to 0.1 per centimeter for ultrapure water below 20 microsiemens per centimeter, 1 per centimeter for 10 to 20,000 microsiemens per centimeter, and 10 per centimeter for higher values.