Skip to main content
Lab Manufacturers China
Pen-Type pH Tester — product photo

Pen-Type pH Tester

笔式 pH 测试仪

  • SKU PHM-0003
  • pH Meters
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
pH range0.00–14.00 pH
pH resolution0.1 or 0.01 pH
pH accuracy±0.1 pH (basic); ±0.01–0.05 pH (advanced)
Temperature range0–60 °C (display)
Calibration points1 to 3 points
Temperature compensationAutomatic, 0–50 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <791>, Ph. Eur. 2.2.3, ASTM E70

What is the Pen-Type pH Tester?

A pen-type pH tester is a compact, low-cost pocket instrument with an integrated electrode and ±0.1 or ±0.01 pH accuracy. It is used for quick screening in gardening, pools, aquariums, food service and teaching where laboratory-grade documentation is not required.

What is the Pen-Type pH Tester?

A pen-type pH tester is a compact, low-cost pocket instrument with an integrated electrode and ±0.1 or ±0.01 pH accuracy. It is used for quick screening in gardening, pools, aquariums, food service and teaching where laboratory-grade documentation is not required.

Overview

The pen tester integrates a small glass or ISFET electrode, electronics, display and battery in a single waterproof body about 15 to 20 cm long. It is operated with one hand, calibrates automatically with one to three buffers and compensates for temperature. Typical accuracy is ±0.1 pH for basic models and ±0.01 to ±0.05 pH for higher-grade versions with replaceable electrodes. The power is supplied by button cells or AAA batteries for 100 to 300 hours. Some testers include a flat or spear tip for direct measurement on surfaces, meat, cheese, soil or small sample volumes. Because the sensor and electronics are compact, stability, resolution and lifetime are lower than in meter and electrode systems, and the whole pen may need replacement when the sensor ages unless the tip is replaceable. They are appropriate for screening, teaching and non-critical checks.

How does it work?

A pH meter is a high-impedance voltmeter connected to a measuring electrode and a reference electrode, often combined in one probe. The glass membrane at the electrode tip develops a potential that depends on the hydrogen ion activity difference between the internal fill solution and the sample, described by the Nernst equation. At 25 degrees Celsius the ideal slope is 59.16 mV per pH unit. The reference electrode, usually silver/silver chloride in potassium chloride electrolyte, supplies a stable potential through a porous junction. The meter amplifies the millivolt signal with input impedance above 10¹² ohms, applies temperature compensation from a thermistor or Pt1000 sensor, and uses a two- to five-point calibration with buffers to correct offset and slope. Modern meters store calibration data, check electrode slope and offset, and export results with date, time and operator identification for good laboratory practice.

What are the key features?

  • Single-hand operation with integrated electrode, electronics and display in one body
  • Automatic one- to three-point calibration with temperature compensation
  • Waterproof housing with floating design for accidental immersion
  • Flat or spear tip options for surface, semi-solid or small-volume samples
  • Replaceable electrode tip on higher-grade versions to extend service life
  • Auto power-off and hold function to save battery and capture stable values

What are the technical specifications?

A typical pen-type ph tester configuration offers pH range of 0.00–14.00 pH, pH resolution of 0.1 or 0.01 pH, pH accuracy of ±0.1 pH (basic); ±0.01–0.05 pH (advanced), temperature range of 0–60 °C (display), calibration points of 1 to 3 points and temperature compensation of Automatic, 0–50 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Pen-Type pH Tester is used in swimming pool and aquarium checks, hydroponics and garden monitoring, food service screening, classroom demonstrations and spot checks in water treatment. Across the wider pH Meters class, laboratories also deploy it for pharmaceutical QC and buffer preparation, drinking water and wastewater testing and food and beverage production control.

Which standards and certifications apply?

Relevant standards and methods include USP <791>, Ph. Eur. 2.2.3, ASTM E70, ASTM D1293, ISO 10523, GB/T 6920 and IEC 60746-2. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Store electrodes in the recommended storage solution and never in deionized water. Calibrate with fresh, traceable buffers bracketing the sample pH, verify slope between 95 and 105 percent, and record the offset. Rinse the electrode between samples and clean it periodically with protein or inorganic cleaning solutions. Keep the meter away from strong electromagnetic fields and ensure samples are at a stable temperature or use automatic compensation. Replace electrodes when response slows or slope drops. Regulated laboratories should schedule calibration verification, document maintenance in the equipment log and follow USP <791> or Ph. Eur. 2.2.3 requirements. Use appropriate chemical-resistant bench space and handle buffers according to local safety rules.

How do I select the right Pen-Type pH Tester?

Choose a pen tester for quick, low-cost screening where ±0.1 pH is acceptable. It is unsuitable for pharmacopoeial or regulated measurements. In an RFQ specify accuracy grade, tip type, whether the electrode is replaceable, ingress protection and required accessories such as buffer sachets and carrying case.

How does it compare with other pH Meters variants?

The decisive parameters are accuracy and resolution, portability, sample type and compliance needs. Benchtop meters give resolution of 0.001 pH and accuracy of about ±0.002 pH, suitable for pharmacopoeial work. Portable meters trade some resolution for ruggedness, IP-rated housings and battery operation for field and plant use. Pen testers suit quick checks at ±0.1 pH. Online analyzers add continuous measurement, cleaning and control outputs for processes. Also consider the electrode, since glass composition, junction type and body material must suit the sample: Tris buffers, low-ionic-strength water, viscous samples, emulsions and semi-solids each need a specific design. For regulated laboratories, check GLP data handling, calibration reminders, password control and compatibility with USP <791>. Include electrode replacement and buffer costs in ownership estimates.

Full specifications

Full specifications
pH range0.00–14.00 pH
pH resolution0.1 or 0.01 pH
pH accuracy±0.1 pH (basic); ±0.01–0.05 pH (advanced)
Temperature range0–60 °C (display)
Calibration points1 to 3 points
Temperature compensationAutomatic, 0–50 °C
Ingress protectionIP65–IP67
Battery type and lifeButton/AAA, 100–300 h
Lengthapprox. 15–20 cm
Weightapprox. 50–100 g

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Swimming pool and aquarium checks
  • Hydroponics and garden monitoring
  • Food service screening
  • Classroom demonstrations
  • Spot checks in water treatment

Key features

  • Single-hand operation with integrated electrode, electronics and display in one body
  • Automatic one- to three-point calibration with temperature compensation
  • Waterproof housing with floating design for accidental immersion
  • Flat or spear tip options for surface, semi-solid or small-volume samples
  • Replaceable electrode tip on higher-grade versions to extend service life
  • Auto power-off and hold function to save battery and capture stable values

Frequently asked questions about Pen-Type pH Tester

Basic pen testers are accurate to about ±0.1 pH, while advanced models reach ±0.01 to ±0.05 pH with correct calibration. Accuracy degrades as the sensor ages, so frequent calibration with fresh buffer is necessary for meaningful results.

Related models

All pH Meters

Request a quotation for the Pen-Type pH Tester

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote