Benchtop pH Meter
台式 pH 计
- SKU PHM-0001
- pH Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| pH range | −2.000 to 20.000 pH |
|---|---|
| pH resolution | 0.001 / 0.01 / 0.1 pH |
| pH accuracy | ±0.002 pH |
| mV range | ±1999.9 mV |
| mV accuracy | ±0.1 mV |
| Temperature range | −5 to 105 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <791>, Ph. Eur. 2.2.3, ASTM E70
What is the Benchtop pH Meter?
A benchtop pH meter is a mains-powered laboratory instrument with resolution to 0.001 pH, multi-point calibration and GLP data handling. It is the standard choice for pharmacopoeial testing, research and quality control where accuracy and traceable records matter more than portability.
What is the Benchtop pH Meter?
A benchtop pH meter is a mains-powered laboratory instrument with resolution to 0.001 pH, multi-point calibration and GLP data handling. It is the standard choice for pharmacopoeial testing, research and quality control where accuracy and traceable records matter more than portability.
Overview
The benchtop meter is designed for fixed laboratory use and offers the highest accuracy in the pH meter family. A large graphic or touchscreen display shows pH, millivolts, temperature and calibration status, and the instrument typically accepts automatic buffer recognition for up to five points with several buffer families including NIST, DIN and technical sets. Resolution of 0.001 pH and accuracy of ±0.002 pH are common, supported by a high-impedance input and a stable analog-to-digital converter. GLP features include calibration history, electrode slope and offset logging, user management, password protection and storage of several thousand measurements. USB or Ethernet output transfers data to a LIMS or printer. Many models support an electrode stand, stirrer and automatic temperature compensation with Pt1000 or NTC probes. They are suited to pharmacopoeial pH tests, buffer preparation, formulation development and teaching laboratories.
How does it work?
A pH meter is a high-impedance voltmeter connected to a measuring electrode and a reference electrode, often combined in one probe. The glass membrane at the electrode tip develops a potential that depends on the hydrogen ion activity difference between the internal fill solution and the sample, described by the Nernst equation. At 25 degrees Celsius the ideal slope is 59.16 mV per pH unit. The reference electrode, usually silver/silver chloride in potassium chloride electrolyte, supplies a stable potential through a porous junction. The meter amplifies the millivolt signal with input impedance above 10¹² ohms, applies temperature compensation from a thermistor or Pt1000 sensor, and uses a two- to five-point calibration with buffers to correct offset and slope. Modern meters store calibration data, check electrode slope and offset, and export results with date, time and operator identification for good laboratory practice.
What are the key features?
- Resolution of 0.001 pH with accuracy of ±0.002 pH for pharmacopoeial work
- Automatic buffer recognition with up to five-point calibration and multiple buffer families
- GLP-compliant logging of calibration, user, date, time and electrode identity
- Automatic temperature compensation using Pt1000 or NTC probe inputs
- USB and Ethernet output for LIMS integration and printer connection
- Electrode holder and optional stirrer stand for repeatable measurements
What are the technical specifications?
A typical benchtop ph meter configuration offers pH range of −2.000 to 20.000 pH, pH resolution of 0.001 / 0.01 / 0.1 pH, pH accuracy of ±0.002 pH, mV range of ±1999.9 mV, mV accuracy of ±0.1 mV and temperature range of −5 to 105 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop pH Meter is used in pharmacopoeial pH testing, buffer and media preparation, formulation development, teaching laboratories and routine QC in food and chemicals. Across the wider pH Meters class, laboratories also deploy it for pharmaceutical QC and buffer preparation, drinking water and wastewater testing and food and beverage production control.
Which standards and certifications apply?
Relevant standards and methods include USP <791>, Ph. Eur. 2.2.3, ASTM E70, ASTM D1293, ISO 10523, GB/T 6920 and IEC 60746-2. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Store electrodes in the recommended storage solution and never in deionized water. Calibrate with fresh, traceable buffers bracketing the sample pH, verify slope between 95 and 105 percent, and record the offset. Rinse the electrode between samples and clean it periodically with protein or inorganic cleaning solutions. Keep the meter away from strong electromagnetic fields and ensure samples are at a stable temperature or use automatic compensation. Replace electrodes when response slows or slope drops. Regulated laboratories should schedule calibration verification, document maintenance in the equipment log and follow USP <791> or Ph. Eur. 2.2.3 requirements. Use appropriate chemical-resistant bench space and handle buffers according to local safety rules.
How do I select the right Benchtop pH Meter?
Choose a benchtop meter for accuracy-critical work, pharmacopoeial testing and any laboratory that needs GLP records. It is unnecessary for rough field checks. In an RFQ specify resolution, calibration point count, data output, compliance features, electrode type for your samples and whether a stirrer stand or second channel is needed.
How does it compare with other pH Meters variants?
The decisive parameters are accuracy and resolution, portability, sample type and compliance needs. Benchtop meters give resolution of 0.001 pH and accuracy of about ±0.002 pH, suitable for pharmacopoeial work. Portable meters trade some resolution for ruggedness, IP-rated housings and battery operation for field and plant use. Pen testers suit quick checks at ±0.1 pH. Online analyzers add continuous measurement, cleaning and control outputs for processes. Also consider the electrode, since glass composition, junction type and body material must suit the sample: Tris buffers, low-ionic-strength water, viscous samples, emulsions and semi-solids each need a specific design. For regulated laboratories, check GLP data handling, calibration reminders, password control and compatibility with USP <791>. Include electrode replacement and buffer costs in ownership estimates.
Full specifications
| pH range | −2.000 to 20.000 pH |
|---|---|
| pH resolution | 0.001 / 0.01 / 0.1 pH |
| pH accuracy | ±0.002 pH |
| mV range | ±1999.9 mV |
| mV accuracy | ±0.1 mV |
| Temperature range | −5 to 105 °C |
| Calibration points | Up to 5 points |
| Input impedance | > 10¹² Ω |
| Data storage | ≥ 1000 results |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pharmacopoeial pH testing
- Buffer and media preparation
- Formulation development
- Teaching laboratories
- Routine QC in food and chemicals
Key features
- Resolution of 0.001 pH with accuracy of ±0.002 pH for pharmacopoeial work
- Automatic buffer recognition with up to five-point calibration and multiple buffer families
- GLP-compliant logging of calibration, user, date, time and electrode identity
- Automatic temperature compensation using Pt1000 or NTC probe inputs
- USB and Ethernet output for LIMS integration and printer connection
- Electrode holder and optional stirrer stand for repeatable measurements
Frequently asked questions about Benchtop pH Meter
Good benchtop meters specify ±0.002 pH for the electronics with 0.001 pH resolution. Real-world accuracy also depends on electrode quality, buffer accuracy, temperature and calibration, and is usually around ±0.01 pH after proper calibration.
Many models offer dual or multi-channel inputs so two or more electrodes can be connected and measured alternately or simultaneously. This is useful for comparing samples, saving calibration time and measuring pH and ion concentration with one instrument.
It is not legally required for every laboratory, but regulated environments such as pharmaceutical QC depend on traceable calibration and measurement records. GLP logging also speeds up audits by linking results to user, electrode and calibration details.
A pH meter measures the activity of hydrogen ions in a solution by reading the potential of a glass electrode against a reference electrode. The value is reported on a scale usually from 0 to 14, indicating acidity below 7 and alkalinity above 7 at 25 degrees Celsius.
Use at least two buffers that bracket the expected sample pH, such as 4.01 and 7.00 for acidic samples or 7.00 and 10.01 for alkaline ones. Three-point calibration improves accuracy across a wider range, and pharmacopoeial work often requires it.
Common causes are a clogged or dry reference junction, an aging glass membrane, low-ionic-strength samples, air bubbles, electrical interference or temperature differences. Cleaning the electrode, refilling the electrolyte, recalibrating and using a suitable electrode usually resolve the drift.