Multiparameter Benchtop pH/Conductivity Meter
多参数台式 pH/电导率仪
- SKU PHM-0005
- pH Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| pH range | −2.000 to 20.000 pH |
|---|---|
| pH accuracy | ±0.002 pH |
| Conductivity range | 0.01 µS/cm–500 mS/cm |
| Conductivity accuracy | ±0.5% of reading |
| TDS range | 0–500 g/L |
| Temperature range | −5 to 105 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <791>, Ph. Eur. 2.2.3, ASTM E70
What is the Multiparameter Benchtop pH/Conductivity Meter?
A multiparameter benchtop meter combines pH, mV, conductivity, TDS and often dissolved oxygen channels in one instrument. It reduces bench space and calibration effort in laboratories that measure several water or solution parameters on the same sample.
What is the Multiparameter Benchtop pH/Conductivity Meter?
A multiparameter benchtop meter combines pH, mV, conductivity, TDS and often dissolved oxygen channels in one instrument. It reduces bench space and calibration effort in laboratories that measure several water or solution parameters on the same sample.
Overview
This variant provides two to four independent input channels in a single housing, so that a pH electrode, a conductivity cell and optionally a dissolved oxygen or ion-selective electrode can be connected at the same time. The software displays all parameters side by side, applies the correct temperature compensation for each and stores results together with sample identification. Conductivity typically covers 0.01 microsiemens per centimeter to 500 millisiemens per centimeter with automatic range selection and cell constants from 0.1 to 10 per centimeter. Users can move quickly through sample sequences without swapping instruments, which saves time in water testing, environmental and beverage laboratories. Digital smart sensors with stored calibration data are common. Trade-offs include more complex menus, a higher purchase price and the fact that a fault in one module can remove several functions from service.
How does it work?
A pH meter is a high-impedance voltmeter connected to a measuring electrode and a reference electrode, often combined in one probe. The glass membrane at the electrode tip develops a potential that depends on the hydrogen ion activity difference between the internal fill solution and the sample, described by the Nernst equation. At 25 degrees Celsius the ideal slope is 59.16 mV per pH unit. The reference electrode, usually silver/silver chloride in potassium chloride electrolyte, supplies a stable potential through a porous junction. The meter amplifies the millivolt signal with input impedance above 10¹² ohms, applies temperature compensation from a thermistor or Pt1000 sensor, and uses a two- to five-point calibration with buffers to correct offset and slope. Modern meters store calibration data, check electrode slope and offset, and export results with date, time and operator identification for good laboratory practice.
What are the key features?
- Two to four input channels for pH, conductivity, TDS and optional dissolved oxygen
- Automatic conductivity range selection from 0.01 µS/cm to 500 mS/cm
- Independent temperature compensation and calibration for each parameter
- Smart digital sensor recognition with stored calibration data
- Sample-ID based data storage and export by USB or LIMS connection
- Compliance with pharmacopoeial conductivity and pH procedures where validated
What are the technical specifications?
A typical multiparameter benchtop ph/conductivity meter configuration offers pH range of −2.000 to 20.000 pH, pH accuracy of ±0.002 pH, conductivity range of 0.01 µS/cm–500 mS/cm, conductivity accuracy of ±0.5% of reading, TDS range of 0–500 g/L and temperature range of −5 to 105 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Multiparameter Benchtop pH/Conductivity Meter is used in drinking water analysis, environmental laboratories, beverage production QC, hydroponics and agriculture labs and pharmaceutical water checks. Across the wider pH Meters class, laboratories also deploy it for pharmaceutical QC and buffer preparation, drinking water and wastewater testing and food and beverage production control.
Which standards and certifications apply?
Relevant standards and methods include USP <791>, Ph. Eur. 2.2.3, ASTM E70, ASTM D1293, ISO 10523, GB/T 6920 and IEC 60746-2. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Store electrodes in the recommended storage solution and never in deionized water. Calibrate with fresh, traceable buffers bracketing the sample pH, verify slope between 95 and 105 percent, and record the offset. Rinse the electrode between samples and clean it periodically with protein or inorganic cleaning solutions. Keep the meter away from strong electromagnetic fields and ensure samples are at a stable temperature or use automatic compensation. Replace electrodes when response slows or slope drops. Regulated laboratories should schedule calibration verification, document maintenance in the equipment log and follow USP <791> or Ph. Eur. 2.2.3 requirements. Use appropriate chemical-resistant bench space and handle buffers according to local safety rules.
How do I select the right Multiparameter Benchtop pH/Conductivity Meter?
Choose a multiparameter meter when several parameters are routinely read on the same sample and bench space is limited. If you only measure pH, a dedicated pH meter is simpler. In an RFQ specify channel count, parameters and ranges, sensor types, cell constants, compliance features and data output.
How does it compare with other pH Meters variants?
The decisive parameters are accuracy and resolution, portability, sample type and compliance needs. Benchtop meters give resolution of 0.001 pH and accuracy of about ±0.002 pH, suitable for pharmacopoeial work. Portable meters trade some resolution for ruggedness, IP-rated housings and battery operation for field and plant use. Pen testers suit quick checks at ±0.1 pH. Online analyzers add continuous measurement, cleaning and control outputs for processes. Also consider the electrode, since glass composition, junction type and body material must suit the sample: Tris buffers, low-ionic-strength water, viscous samples, emulsions and semi-solids each need a specific design. For regulated laboratories, check GLP data handling, calibration reminders, password control and compatibility with USP <791>. Include electrode replacement and buffer costs in ownership estimates.
Full specifications
| pH range | −2.000 to 20.000 pH |
|---|---|
| pH accuracy | ±0.002 pH |
| Conductivity range | 0.01 µS/cm–500 mS/cm |
| Conductivity accuracy | ±0.5% of reading |
| TDS range | 0–500 g/L |
| Temperature range | −5 to 105 °C |
| Number of channels | 2–4 |
| Cell constants supported | 0.1, 1, 10 cm⁻¹ |
| Data storage | ≥ 2000 results |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water analysis
- Environmental laboratories
- Beverage production QC
- Hydroponics and agriculture labs
- Pharmaceutical water checks
Key features
- Two to four input channels for pH, conductivity, TDS and optional dissolved oxygen
- Automatic conductivity range selection from 0.01 µS/cm to 500 mS/cm
- Independent temperature compensation and calibration for each parameter
- Smart digital sensor recognition with stored calibration data
- Sample-ID based data storage and export by USB or LIMS connection
- Compliance with pharmacopoeial conductivity and pH procedures where validated
Frequently asked questions about Multiparameter Benchtop pH/Conductivity Meter
Yes. A multiparameter meter has separate input channels and can read both sensors simultaneously. Keep in mind that pH electrodes can leach ions that affect conductivity in very pure water, so measure low-conductivity samples with care or use separate sample portions.
Not necessarily. Many multiparameter benchtop meters use the same electronics as dedicated models and reach ±0.002 pH and ±0.5 percent conductivity. Accuracy mainly depends on the sensors, calibration quality and sample handling.
Calibrate each sensor with its own standards, such as pH buffers and conductivity standard solutions at 84, 1413 or 12880 microsiemens per centimeter. Many instruments guide the sequence and store separate calibration records for every sensor.
A pH meter measures the activity of hydrogen ions in a solution by reading the potential of a glass electrode against a reference electrode. The value is reported on a scale usually from 0 to 14, indicating acidity below 7 and alkalinity above 7 at 25 degrees Celsius.
Use at least two buffers that bracket the expected sample pH, such as 4.01 and 7.00 for acidic samples or 7.00 and 10.01 for alkaline ones. Three-point calibration improves accuracy across a wider range, and pharmacopoeial work often requires it.
Common causes are a clogged or dry reference junction, an aging glass membrane, low-ionic-strength samples, air bubbles, electrical interference or temperature differences. Cleaning the electrode, refilling the electrolyte, recalibrating and using a suitable electrode usually resolve the drift.
Related models