Pen-Type Conductivity and TDS Tester
笔式电导率/TDS 测试仪
- SKU COM-0003
- Conductivity Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Conductivity range | 0–2000 or 0–20,000 µS/cm |
|---|---|
| TDS range | 0–1000 or 0–10,000 ppm |
| Resolution | 1 or 10 µS/cm |
| Accuracy | ±1–2% of full scale |
| Temperature compensation | Automatic, 2%/°C, 0–50 °C |
| TDS factor | 0.5 (fixed or selectable 0.4–0.8) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <645>, Ph. Eur. 2.2.38, ASTM D1125
What is the Pen-Type Conductivity and TDS Tester?
A pen-type conductivity and TDS tester is a pocket-sized waterproof instrument with an integrated electrode, offering ±1 to ±2 percent accuracy. It is meant for quick screening of drinking water, hydroponic solutions, pools and aquariums rather than regulated laboratory measurement.
What is the Pen-Type Conductivity and TDS Tester?
A pen-type conductivity and TDS tester is a pocket-sized waterproof instrument with an integrated electrode, offering ±1 to ±2 percent accuracy. It is meant for quick screening of drinking water, hydroponic solutions, pools and aquariums rather than regulated laboratory measurement.
Overview
The pen tester combines a small stainless steel or graphite electrode, electronics, display and battery into a single body about 15 to 20 cm long. A single button starts measurement and calibration. Typical ranges are 0 to 2000 or 0 to 20,000 microsiemens per centimeter with resolution of 1 or 10 microsiemens per centimeter, and TDS readings use a fixed conversion factor, often 0.5. Automatic temperature compensation is included with a 2 percent per degree coefficient, and some models allow one-point calibration. Accuracy is typically ±1 to ±2 percent of full scale. The instrument is rinsed and capped after use, and the electrode is either permanently fixed or has a replaceable tip. Because the measuring cell geometry is small and open, results can be affected by the sample container and by air bubbles, so the tester is best for trend checks, not for certificates of analysis.
How does it work?
Conductivity is measured by applying an alternating voltage across two or four electrodes of a cell with known geometry and measuring the resulting current. The conductance, in siemens, multiplied by the cell constant (the ratio of electrode spacing to area, in reciprocal centimeters) gives conductivity in microsiemens or millisiemens per centimeter. Alternating current at frequencies from hundreds of hertz to several kilohertz avoids electrode polarization. Conductivity rises by about 2 percent per degree Celsius, so meters compensate to a reference temperature, usually 25 degrees Celsius, using a linear coefficient or a nonlinear function for natural or ultrapure water. Cells with constants of 0.01 to 0.1 per centimeter are used for pure water, 1 per centimeter for general work and 10 per centimeter for concentrated solutions. Inductive cells use two toroidal coils and have no exposed electrodes, which suits aggressive or fouling media. TDS is estimated by multiplying conductivity by a factor of about 0.5 to 0.7.
What are the key features?
- Waterproof pocket body with integrated electrode and one-button operation
- Ranges up to 20,000 µS/cm with resolution of 1 to 10 µS/cm
- Automatic temperature compensation at 2% per °C
- Selectable TDS conversion factor on some models
- Hold function to freeze a stable reading and auto power-off to save battery
- Replaceable electrode tip on higher-grade versions
What are the technical specifications?
A typical pen-type conductivity and tds tester configuration offers conductivity range of 0–2000 or 0–20,000 µS/cm, TDS range of 0–1000 or 0–10,000 ppm, resolution of 1 or 10 µS/cm, accuracy of ±1–2% of full scale, temperature compensation of Automatic, 2%/°C, 0–50 °C and TDS factor of 0.5 (fixed or selectable 0.4–0.8). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Pen-Type Conductivity and TDS Tester is used in drinking water screening, hydroponic nutrient solution checks, swimming pool and aquarium monitoring, classroom demonstrations and water filter performance checks. Across the wider Conductivity Meters class, laboratories also deploy it for pharmaceutical purified water testing, drinking and wastewater monitoring and boiler and cooling water control.
Which standards and certifications apply?
Relevant standards and methods include USP <645>, Ph. Eur. 2.2.38, ASTM D1125, ASTM D5391, ISO 7888, OIML R 68, IEC 60746-3 and GB/T 6908. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate with traceable potassium chloride standards close to the sample range, for example 84, 1413 or 12880 microsiemens per centimeter, at a controlled temperature. For ultrapure water, measure in a flow-through cell to avoid absorption of carbon dioxide, which raises conductivity within minutes. Rinse the cell with sample before measuring and store it dry or in deionized water as recommended. Platinum black coating should be protected from contamination and re-platinized when needed. Verify the cell constant periodically. Pharmaceutical laboratories should follow USP <645> or Ph. Eur. 2.2.38 staged testing and keep calibration and verification records. Keep cables away from power lines to avoid interference and ensure samples are not contaminated by handling.
How do I select the right Pen-Type Conductivity and TDS Tester?
Choose a pen tester for quick, inexpensive checks where ±2 percent is acceptable. It is not suitable for pharmaceutical water or accredited testing. In an RFQ specify range, resolution, TDS factor, replaceable tip requirement and accessories such as calibration solution.
How does it compare with other Conductivity Meters variants?
Start with the conductivity range of your samples, because the cell constant must match it: use 0.01 to 0.1 per centimeter for ultrapure water, 1 per centimeter for drinking water and most laboratory work, and 10 per centimeter for brines and concentrated solutions. Then choose the format. Benchtop meters give the best accuracy and GLP features, portable meters suit field sampling and plant rounds, pen testers suit screening, and online analyzers give continuous monitoring with relay and 4–20 mA outputs. Pharmaceutical water testing requires a meter and cell that support USP <645> with temperature compensation disabled and calibration traceable to standards. For fouling or corrosive media consider inductive sensors. Check the accuracy specification, temperature compensation options, cell material and the cost of calibration standards.
Full specifications
| Conductivity range | 0–2000 or 0–20,000 µS/cm |
|---|---|
| TDS range | 0–1000 or 0–10,000 ppm |
| Resolution | 1 or 10 µS/cm |
| Accuracy | ±1–2% of full scale |
| Temperature compensation | Automatic, 2%/°C, 0–50 °C |
| TDS factor | 0.5 (fixed or selectable 0.4–0.8) |
| Calibration | 1-point |
| Battery | Button cells or AAA, 100–200 h |
| Ingress protection | IP65–IP67 |
| Weight | approx. 50–100 g |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water screening
- Hydroponic nutrient solution checks
- Swimming pool and aquarium monitoring
- Classroom demonstrations
- Water filter performance checks
Key features
- Waterproof pocket body with integrated electrode and one-button operation
- Ranges up to 20,000 µS/cm with resolution of 1 to 10 µS/cm
- Automatic temperature compensation at 2% per °C
- Selectable TDS conversion factor on some models
- Hold function to freeze a stable reading and auto power-off to save battery
- Replaceable electrode tip on higher-grade versions
Frequently asked questions about Pen-Type Conductivity and TDS Tester
A TDS pen is a conductivity meter that displays the reading converted to ppm using a fixed factor. It therefore estimates dissolved solids and can be misleading if the ion mixture differs from the calibration standard.
Immerse the electrode in a standard solution, such as 1413 microsiemens per centimeter, wait for a stable reading and press the calibration button or adjust the trimmer. Use fresh standard at 25 degrees Celsius and rinse the pen with deionized water afterwards.
Common causes are air bubbles on the electrode, sample container contact, temperature differences and insufficient stabilization time. Tap the pen gently, use a clean beaker of adequate volume and wait for the stable indicator before recording.
It measures how well a solution conducts electricity, reported in microsiemens or millisiemens per centimeter. Because dissolved ions carry the current, conductivity indicates total ionic content and is used for water purity, salinity and TDS estimation.
TDS meters measure conductivity and multiply it by a conversion factor, commonly 0.5 to 0.7, to estimate dissolved solids in mg/L. The factor depends on the ion mix, so the result is an estimate unless verified against gravimetric TDS.
Choose a cell constant that places the sample in the middle of the cell range: 0.01 to 0.1 per centimeter for ultrapure water below 20 microsiemens per centimeter, 1 per centimeter for 10 to 20,000 microsiemens per centimeter, and 10 per centimeter for higher values.