Water Analysis Colorimeter
水质分析色度计
- SKU COL-0003
- Colorimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Reagent-based filter photometry |
|---|---|
| Preset wavelengths | 430, 520, 620 nm |
| Typical parameters | Free and total chlorine, iron, nitrate |
| Chlorine range | 0–5 mg/L as Cl₂ |
| Light source | LED |
| Detector | Silicon photodiode |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7887, ASTM D1209, ASTM E313
What is the Water Analysis Colorimeter?
A water analysis colorimeter is a filter photometer dedicated to reagent-based tests for parameters such as chlorine, iron and nitrate. Pre-programmed methods and parameter-specific wavelengths make it a routine tool for drinking water and wastewater laboratories.
What is the Water Analysis Colorimeter?
A water analysis colorimeter is a filter photometer dedicated to reagent-based tests for parameters such as chlorine, iron and nitrate. Pre-programmed methods and parameter-specific wavelengths make it a routine tool for drinking water and wastewater laboratories.
Overview
A water analysis colorimeter combines fixed light-emitting diode wavelengths with stored calibrations for specific reagents and parameters. The operator adds a reagent to a water sample, waits for colour development and reads the concentration directly in the appropriate unit, such as mg/L. Multiple preset parameters reduce operator error and speed batch testing. Some models include turbidity or pH options, and results can be logged or exported. Because the chemistry is defined by the reagent supplier, the instrument and reagents must be matched. Regular blanking and standard checks maintain accuracy across the working range. Stored programmes can be updated when reagent formulations change.
How does it work?
A colorimeter passes light from a lamp or light-emitting diode through a coloured filter, then through the sample or onto the sample, and measures the transmitted or reflected intensity with a photodetector. The filter selects a band where the analyte absorbs, so the measured change follows the Beer–Lambert law for concentration work. For colour measurement, the instrument uses tristimulus filters or illumination geometry to compute colour coordinates in spaces such as CIELAB. The electrical signal is converted to absorbance, transmittance, concentration or a colour difference value against a stored reference. Because filters are fixed, only a few wavelengths are available, which limits selectivity but keeps the instrument robust and easy to operate.
What are the key features?
- Pre-programmed methods for common water parameters
- Parameter-specific LED wavelengths for reagent chemistry
- Direct concentration readout in mg/L or equivalent
- Data logging and export for compliance records
- Optional turbidity and pH measurement modes
What are the technical specifications?
A typical water analysis colorimeter configuration offers measurement principle of Reagent-based filter photometry, preset wavelengths of 430, 520, 620 nm, typical parameters of Free and total chlorine, iron, nitrate, chlorine range of 0–5 mg/L as Cl₂, light source of LED and detector of Silicon photodiode. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Water Analysis Colorimeter is used in drinking water disinfection monitoring, wastewater treatment plant control, swimming pool and spa water testing and industrial cooling and boiler water checks. Across the wider Colorimeters class, laboratories also deploy it for water and wastewater colour and ion testing, food and beverage colour grading and plastic, paint and coating colour control.
Which standards and certifications apply?
Relevant standards and methods include ISO 7887, ASTM D1209, ASTM E313, CIE 15 and USP <1061>. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the instrument on a level, stable surface away from strong stray light, which can bias colour readings. Keep cells and apertures clean and free of scratches, and use matched cells for concentration measurement. Verify performance regularly with reference standards, filters or certified colour tiles, and record results for trend monitoring. For reagent-based water testing, follow reagent shelf life and blanking procedures. Recalibrate or re-standardize at the interval defined by the quality system, and clean the illumination path as instructed. Protect portable units from moisture and impact.
How do I select the right Water Analysis Colorimeter?
Select a water analysis colorimeter when reagent-based testing of defined parameters is routine. Confirm that the instrument supports the parameters and ranges required and that reagents are readily available and matched to the instrument. Consider data logging, waterproofing and the working environment, and verify the stated accuracy at the concentration of interest.
How does it compare with other Colorimeters variants?
Decide first whether the measurement concerns chemical concentration or surface colour. Concentration work in water, food or clinical testing suits a filter colorimeter with reagent-specific wavelengths, and pre-set calibrations speed routine testing. Colour grading of plastics, textiles, paints and packaging requires a colour difference meter with defined geometry and colour spaces. Portable models suit field and incoming inspection, while benchtop models give better repeatability for the laboratory. Check wavelength or illuminant options, measurement aperture, repeatability, data storage and connectivity, and the availability of certified colour standards for verification.
Full specifications
| Measurement principle | Reagent-based filter photometry |
|---|---|
| Preset wavelengths | 430, 520, 620 nm |
| Typical parameters | Free and total chlorine, iron, nitrate |
| Chlorine range | 0–5 mg/L as Cl₂ |
| Light source | LED |
| Detector | Silicon photodiode |
| Protection class | IP67 |
| Data storage | Up to 1,000 readings |
| Power supply | 4 × AAA batteries |
| Data interface | USB |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water disinfection monitoring
- Wastewater treatment plant control
- Swimming pool and spa water testing
- Industrial cooling and boiler water checks
Key features
- Pre-programmed methods for common water parameters
- Parameter-specific LED wavelengths for reagent chemistry
- Direct concentration readout in mg/L or equivalent
- Data logging and export for compliance records
- Optional turbidity and pH measurement modes
Frequently asked questions about Water Analysis Colorimeter
Each reagent produces a specific colour whose absorbance must be measured at a defined wavelength and converted using a specific calibration. Using a reagent from a different supplier may give a different colour development or interfering response, so the instrument programme and the reagent must be validated together.
Most tests require adding reagent, a reaction time of one to five minutes and a reading, so a single measurement takes a few minutes. Batch throughput depends on reaction time and sample preparation. Preset programmes remove the need to build calibration curves manually.
Yes, many water analysis colorimeters store programmes for multiple parameters and use different wavelengths or reagents for each. The operator selects the parameter and follows its reagent procedure. Cross-contamination between tests is avoided by rinsing cells thoroughly.
A colorimeter uses a few broad-band filters and is simple and economical, suitable for defined routine tests. A spectrophotometer uses a monochromator or grating to scan many wavelengths, giving higher selectivity and spectral information. Colorimeters are ideal where the method specifies a fixed wavelength.
Colour difference is most often expressed as ΔE*ab in the CIELAB space, calculated from differences in lightness and two chromatic axes. Smaller values indicate closer colour match. Acceptable limits depend on the industry and are agreed between supplier and customer.
Geometry defines the illumination and viewing angles, such as 45/0 or d/8. Different geometries respond differently to surface gloss, texture and orientation, so instruments with different geometries can give different values for the same sample. Comparing results requires consistent geometry.
Related models