Benchtop Colorimeter
台式色度计
- SKU COL-0001
- Colorimeters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Filter photometry |
|---|---|
| Wavelength range | 400–700 nm |
| Standard wavelengths | 420, 470, 530, 620 nm |
| Light source | LED |
| Detector | Silicon photodiode |
| Photometric range | 0–2 A |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7887, ASTM D1209, ASTM E313
What is the Benchtop Colorimeter?
A benchtop colorimeter is a stable laboratory instrument that measures absorbance or colour of liquid samples in fixed cells. It is used for routine concentration, colour scale and quality-control tests where repeatability and simple operation matter.
What is the Benchtop Colorimeter?
A benchtop colorimeter is a stable laboratory instrument that measures absorbance or colour of liquid samples in fixed cells. It is used for routine concentration, colour scale and quality-control tests where repeatability and simple operation matter.
Overview
A benchtop colorimeter houses a stable light source, a set of interference filters and a photodetector in a fixed optical geometry. Samples are placed in standard cuvettes or flow-through cells in a covered compartment that excludes ambient light. Wavelengths are selected for common colorimetric reactions or colour scales, so operators can run defined methods without adjusting optics. Microprocessor control provides calibration curves, blanking and direct concentration readout. Because the design is simple and robust, repeatability is good and maintenance is limited to lamp and filter care, making the instrument well suited to high-throughput routine testing.
How does it work?
A colorimeter passes light from a lamp or light-emitting diode through a coloured filter, then through the sample or onto the sample, and measures the transmitted or reflected intensity with a photodetector. The filter selects a band where the analyte absorbs, so the measured change follows the Beer–Lambert law for concentration work. For colour measurement, the instrument uses tristimulus filters or illumination geometry to compute colour coordinates in spaces such as CIELAB. The electrical signal is converted to absorbance, transmittance, concentration or a colour difference value against a stored reference. Because filters are fixed, only a few wavelengths are available, which limits selectivity but keeps the instrument robust and easy to operate.
What are the key features?
- Stable LED or tungsten light source with interference filters
- Covered sample compartment to exclude ambient light
- Direct concentration readout from stored calibration curves
- Standard 10 mm cuvette and flow-cell compatibility
- USB output for data export to a laboratory system
What are the technical specifications?
A typical benchtop colorimeter configuration offers measurement principle of Filter photometry, wavelength range of 400–700 nm, standard wavelengths of 420, 470, 530, 620 nm, light source of LED, detector of Silicon photodiode and photometric range of 0–2 A. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Colorimeter is used in water and wastewater colorimetric testing, food and beverage quality control, pharmaceutical colorimetric assays and teaching and general laboratory analysis. Across the wider Colorimeters class, laboratories also deploy it for water and wastewater colour and ion testing, food and beverage colour grading and plastic, paint and coating colour control.
Which standards and certifications apply?
Relevant standards and methods include ISO 7887, ASTM D1209, ASTM E313, CIE 15 and USP <1061>. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the instrument on a level, stable surface away from strong stray light, which can bias colour readings. Keep cells and apertures clean and free of scratches, and use matched cells for concentration measurement. Verify performance regularly with reference standards, filters or certified colour tiles, and record results for trend monitoring. For reagent-based water testing, follow reagent shelf life and blanking procedures. Recalibrate or re-standardize at the interval defined by the quality system, and clean the illumination path as instructed. Protect portable units from moisture and impact.
How do I select the right Benchtop Colorimeter?
Choose a benchtop colorimeter when a fixed, method-defined wavelength is used and throughput matters. Confirm that the available filters match the required methods, that the sample compartment accepts the cells in use, and that software can store calibration curves and export results. For regulated laboratories, verify data handling and calibration record features.
How does it compare with other Colorimeters variants?
Decide first whether the measurement concerns chemical concentration or surface colour. Concentration work in water, food or clinical testing suits a filter colorimeter with reagent-specific wavelengths, and pre-set calibrations speed routine testing. Colour grading of plastics, textiles, paints and packaging requires a colour difference meter with defined geometry and colour spaces. Portable models suit field and incoming inspection, while benchtop models give better repeatability for the laboratory. Check wavelength or illuminant options, measurement aperture, repeatability, data storage and connectivity, and the availability of certified colour standards for verification.
Full specifications
| Measurement principle | Filter photometry |
|---|---|
| Wavelength range | 400–700 nm |
| Standard wavelengths | 420, 470, 530, 620 nm |
| Light source | LED |
| Detector | Silicon photodiode |
| Photometric range | 0–2 A |
| Photometric accuracy | ±0.005 A at 1 A |
| Sample holder | 10 mm cuvette, flow cell option |
| Display | Colour LCD |
| Data interface | USB, RS-232 |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Water and wastewater colorimetric testing
- Food and beverage quality control
- Pharmaceutical colorimetric assays
- Teaching and general laboratory analysis
Key features
- Stable LED or tungsten light source with interference filters
- Covered sample compartment to exclude ambient light
- Direct concentration readout from stored calibration curves
- Standard 10 mm cuvette and flow-cell compatibility
- USB output for data export to a laboratory system
Frequently asked questions about Benchtop Colorimeter
Most benchtop colorimeters accept standard 10 mm path-length cuvettes in glass, plastic or quartz. Some models also accept flow-through cells, test tubes or micro-volume adapters. Match the cell material and path length to the wavelength and the method.
The operator measures a series of standards and the instrument fits a curve, which is saved with the method name. Subsequent samples are read against that curve and reported directly in concentration units. Curves should be verified periodically with independent standards.
Turbidity scatters light and can bias absorbance readings, so turbid samples usually require filtration, clarification or a different measurement mode such as nephelometry. Some instruments include turbidity compensation, but results should be confirmed against a reference method.
A colorimeter uses a few broad-band filters and is simple and economical, suitable for defined routine tests. A spectrophotometer uses a monochromator or grating to scan many wavelengths, giving higher selectivity and spectral information. Colorimeters are ideal where the method specifies a fixed wavelength.
Colour difference is most often expressed as ΔE*ab in the CIELAB space, calculated from differences in lightness and two chromatic axes. Smaller values indicate closer colour match. Acceptable limits depend on the industry and are agreed between supplier and customer.
Geometry defines the illumination and viewing angles, such as 45/0 or d/8. Different geometries respond differently to surface gloss, texture and orientation, so instruments with different geometries can give different values for the same sample. Comparing results requires consistent geometry.