Fluorescence Spectrometer
荧光光谱仪
- SKU SPC-0002
- Spectrometers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Excitation wavelength range | 200–900 nm |
|---|---|
| Emission wavelength range | 200–900 nm |
| Spectral bandwidth | 5 nm / 10 nm selectable |
| Light source | 150 W xenon lamp |
| Detector | Photomultiplier tube |
| Wavelength accuracy | ±1.0 nm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <857>, Ph. Eur. 2.2.25, ASTM E275
What is the Fluorescence Spectrometer?
A fluorescence spectrometer measures light emitted by a sample after excitation at a shorter wavelength. It offers very low detection limits for fluorescent compounds and is widely used in biochemical assays, pharmaceutical trace analysis and environmental monitoring.
What is the Fluorescence Spectrometer?
A fluorescence spectrometer measures light emitted by a sample after excitation at a shorter wavelength. It offers very low detection limits for fluorescent compounds and is widely used in biochemical assays, pharmaceutical trace analysis and environmental monitoring.
Overview
A fluorescence spectrometer uses a high-intensity xenon lamp to excite a sample, then measures emitted light at a longer wavelength through a second monochromator set at right angles to the excitation path. Two gratings allow independent scanning of excitation and emission spectra. A photomultiplier tube provides high sensitivity for low-level fluorescence. Because detection depends on both excitation and emission wavelengths, selectivity is higher than absorption methods. Quenching, inner-filter effects and scattering must be controlled. Applications include quantification of fluorescent dyes, vitamins, drugs and labelled biomolecules. The instrument is carefully calibrated against suitable reference standards before quantification.
How does it work?
A spectrometer collects light from a source or sample and disperses it with a prism, diffraction grating or interferometer. The separated wavelengths fall on a detector, usually a photodiode, charge-coupled device or photomultiplier, which converts intensity into an electrical signal. The signal is digitized and plotted as intensity versus wavelength or wavenumber. Transmission, absorbance or emission bands reveal molecular or atomic structure, because specific groups absorb or emit at characteristic wavelengths. Optical resolution depends on slit width, grating groove density and detector pixel size, while sensitivity depends on source brightness, optical throughput and detector quantum efficiency. Wavelength calibration against emission lamps or reference standards keeps readings accurate and comparable between instruments.
What are the key features?
- Xenon lamp excitation with dual monochromators
- Independent excitation and emission spectral scanning
- High-sensitivity photomultiplier detection
- Variable spectral bandwidth for resolution control
- Kinetic and time-scan measurement modes
What are the technical specifications?
A typical fluorescence spectrometer configuration offers excitation wavelength range of 200–900 nm, emission wavelength range of 200–900 nm, spectral bandwidth of 5 nm / 10 nm selectable, light source of 150 W xenon lamp, detector of Photomultiplier tube and wavelength accuracy of ±1.0 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Fluorescence Spectrometer is used in biochemical and immunoassay labelling, pharmaceutical trace impurity analysis, water and environmental fluorescence monitoring and food vitamin and pigment quantification. Across the wider Spectrometers class, laboratories also deploy it for pharmaceutical identity and content testing, chemical reaction monitoring and optical coating and filter characterization.
Which standards and certifications apply?
Relevant standards and methods include USP <857>, Ph. Eur. 2.2.25, ASTM E275, ASTM E958 and JP 2.24. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install spectrometers on a stable bench away from vibration and large temperature swings, and allow warm-up for source and detector stability. Protect optics from dust and humidity; hygroscopic components such as KBr windows need desiccation or purging. Establish a calibration schedule covering wavelength accuracy, photometric accuracy and stray light, using traceable filters or lamps. Keep reference spectra and performance records for trend analysis. For regulated work, define user access, audit trails and electronic records, and document installation, operational and performance qualification. Regular lamp replacement and cleaning of sample compartments reduce drift.
How do I select the right Fluorescence Spectrometer?
Choose a fluorescence spectrometer when the analyte fluoresces or can be labelled, and when lower detection limits than absorption are needed. Specify the excitation and emission ranges, detection sensitivity and whether both spectra must be scanned. Confirm that the software supports quantification with standards, and note that quenching and matrix effects require method-specific validation.
How does it compare with other Spectrometers variants?
Choose by measurand first: absorption in the ultraviolet and visible suits a UV-Vis spectrophotometer, trace fluorescence suits a fluorescence spectrometer, non-contact identification of solids and liquids suits a Raman spectrometer, functional-group analysis of solids and liquids suits an FTIR spectrometer, and rapid reflectance or transmission measurements suit a CCD array spectrometer. Then match spectral range, resolution and stray-light performance to the method. Consider whether a double-beam or array design is needed, the required detector sensitivity, and whether a flow cell, fibre probe or integrating sphere is required. Check wavelength accuracy, baseline stability, software for spectral libraries and data integrity, and available calibration standards before specifying.
Full specifications
| Excitation wavelength range | 200–900 nm |
|---|---|
| Emission wavelength range | 200–900 nm |
| Spectral bandwidth | 5 nm / 10 nm selectable |
| Light source | 150 W xenon lamp |
| Detector | Photomultiplier tube |
| Wavelength accuracy | ±1.0 nm |
| Sensitivity | Raman peak of water, S/N ≥ 350 |
| Scan speed | Up to 2400 nm/min |
| Stray light | ≤0.02% T |
| Data interface | USB, LAN |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Biochemical and immunoassay labelling
- Pharmaceutical trace impurity analysis
- Water and environmental fluorescence monitoring
- Food vitamin and pigment quantification
Key features
- Xenon lamp excitation with dual monochromators
- Independent excitation and emission spectral scanning
- High-sensitivity photomultiplier detection
- Variable spectral bandwidth for resolution control
- Kinetic and time-scan measurement modes
Frequently asked questions about Fluorescence Spectrometer
In fluorescence, emitted light is measured against a dark background, so even a small number of photons is detectable. In absorption, a small change is measured against a large background signal. As a result fluorescence detection limits are often many times lower than those of UV-Vis absorption.
Quenching reduces fluorescence intensity through collisional energy transfer, complex formation, temperature, dissolved oxygen or high sample concentration. It can bias quantification, so samples are often diluted and compared against matrix-matched standards within the linear range of the method.
Yes, with the appropriate solid sample holder or front-face geometry. Powders, thin films and solid-surface fluorescence can be measured, but surface roughness and packing affect the signal. Calibration and measurement geometry must be kept consistent for comparable results.
Concentration is usually measured with a UV-Vis spectrophotometer, because absorbance follows the Beer–Lambert law and many compounds absorb strongly in the ultraviolet. Fluorescence spectrometers offer lower detection limits for fluorescent analytes. The correct choice depends on the analyte, matrix and required limit of detection.
Spectral resolution is the smallest wavelength difference the instrument can separate, set by slit width, grating and detector. Higher resolution distinguishes closely spaced bands and sharp peaks but reduces light throughput. Choose resolution that matches the narrowest feature the method must resolve.
Yes. Wavelength accuracy drifts with lamp ageing, mechanical change and temperature. Calibration uses emission lines from deuterium or mercury lamps, or certified reference filters, and is verified against defined tolerances. Records of wavelength, photometric and stray-light checks support traceability.
Related models