Raman Spectrometer
拉曼光谱仪
- SKU SPC-0003
- Spectrometers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Laser wavelength | 532 nm or 785 nm |
|---|---|
| Laser power at sample | Up to 100 mW |
| Spectral range | 200–3200 cm⁻¹ |
| Spectral resolution | ≤2 cm⁻¹ |
| Wavenumber accuracy | ±1 cm⁻¹ |
| Wavenumber repeatability | ±0.2 cm⁻¹ |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <857>, Ph. Eur. 2.2.25, ASTM E275
What is the Raman Spectrometer?
A Raman spectrometer measures inelastic light scattering to reveal molecular vibrations without contact or sample preparation. It is used for rapid material identification, polymorph screening and through-package verification in pharmaceutical and materials laboratories.
What is the Raman Spectrometer?
A Raman spectrometer measures inelastic light scattering to reveal molecular vibrations without contact or sample preparation. It is used for rapid material identification, polymorph screening and through-package verification in pharmaceutical and materials laboratories.
Overview
A Raman spectrometer focuses a monochromatic laser onto a sample and collects the weakly scattered light, in which a small fraction has shifted in wavelength by energies matching molecular vibrations. A notch or edge filter removes the strong Rayleigh line, and a grating and cooled charge-coupled device detector record the Raman shift spectrum, usually plotted in wavenumbers. The 532 nm and 785 nm lasers are common, with 785 nm reducing fluorescence for many samples. Confocal optics allow depth profiling and small spot analysis. Water is a weak Raman scatterer, so aqueous samples can be measured directly.
How does it work?
A spectrometer collects light from a source or sample and disperses it with a prism, diffraction grating or interferometer. The separated wavelengths fall on a detector, usually a photodiode, charge-coupled device or photomultiplier, which converts intensity into an electrical signal. The signal is digitized and plotted as intensity versus wavelength or wavenumber. Transmission, absorbance or emission bands reveal molecular or atomic structure, because specific groups absorb or emit at characteristic wavelengths. Optical resolution depends on slit width, grating groove density and detector pixel size, while sensitivity depends on source brightness, optical throughput and detector quantum efficiency. Wavelength calibration against emission lamps or reference standards keeps readings accurate and comparable between instruments.
What are the key features?
- 532 nm or 785 nm laser excitation options
- Cooled charge-coupled device detector for low noise
- Confocal optics for depth profiling and small spots
- Spectrum library matching for automatic identification
- Fibre-optic probe option for remote sampling
What are the technical specifications?
A typical raman spectrometer configuration offers laser wavelength of 532 nm or 785 nm, laser power at sample of Up to 100 mW, spectral range of 200–3200 cm⁻¹, spectral resolution of ≤2 cm⁻¹, wavenumber accuracy of ±1 cm⁻¹ and wavenumber repeatability of ±0.2 cm⁻¹. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Raman Spectrometer is used in raw material identification in pharmaceutical receiving, polymorph and crystallinity screening, polymer and packaging material verification and forensic and heritage material analysis. Across the wider Spectrometers class, laboratories also deploy it for pharmaceutical identity and content testing, chemical reaction monitoring and optical coating and filter characterization.
Which standards and certifications apply?
Relevant standards and methods include USP <857>, Ph. Eur. 2.2.25, ASTM E275, ASTM E958 and JP 2.24. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install spectrometers on a stable bench away from vibration and large temperature swings, and allow warm-up for source and detector stability. Protect optics from dust and humidity; hygroscopic components such as KBr windows need desiccation or purging. Establish a calibration schedule covering wavelength accuracy, photometric accuracy and stray light, using traceable filters or lamps. Keep reference spectra and performance records for trend analysis. For regulated work, define user access, audit trails and electronic records, and document installation, operational and performance qualification. Regular lamp replacement and cleaning of sample compartments reduce drift.
How do I select the right Raman Spectrometer?
Select a Raman spectrometer for non-contact, largely preparation-free identification of solids, liquids and packaged materials. Choose the laser wavelength according to sample fluorescence, and confirm spectral range, resolution and library coverage. For hazardous or remote samples, specify a fibre-optic probe. In an RFQ state the laser wavelength, power, wavenumber range and required identification software.
How does it compare with other Spectrometers variants?
Choose by measurand first: absorption in the ultraviolet and visible suits a UV-Vis spectrophotometer, trace fluorescence suits a fluorescence spectrometer, non-contact identification of solids and liquids suits a Raman spectrometer, functional-group analysis of solids and liquids suits an FTIR spectrometer, and rapid reflectance or transmission measurements suit a CCD array spectrometer. Then match spectral range, resolution and stray-light performance to the method. Consider whether a double-beam or array design is needed, the required detector sensitivity, and whether a flow cell, fibre probe or integrating sphere is required. Check wavelength accuracy, baseline stability, software for spectral libraries and data integrity, and available calibration standards before specifying.
Full specifications
| Laser wavelength | 532 nm or 785 nm |
|---|---|
| Laser power at sample | Up to 100 mW |
| Spectral range | 200–3200 cm⁻¹ |
| Spectral resolution | ≤2 cm⁻¹ |
| Wavenumber accuracy | ±1 cm⁻¹ |
| Wavenumber repeatability | ±0.2 cm⁻¹ |
| Detector | Cooled charge-coupled device |
| Grating | 1200 lines/mm |
| Integration time | 1 ms to 60 s |
| Data interface | USB, Wi-Fi |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Raw material identification in pharmaceutical receiving
- Polymorph and crystallinity screening
- Polymer and packaging material verification
- Forensic and heritage material analysis
Key features
- 532 nm or 785 nm laser excitation options
- Cooled charge-coupled device detector for low noise
- Confocal optics for depth profiling and small spots
- Spectrum library matching for automatic identification
- Fibre-optic probe option for remote sampling
Frequently asked questions about Raman Spectrometer
Usually very little. Most solid and liquid samples can be measured directly, and glass or plastic packaging is often transparent enough for through-container measurement. Opaque or highly fluorescent samples may need dilution, different laser wavelength or surface cleaning to obtain a usable spectrum.
Shorter wavelengths such as 532 nm give stronger Raman scattering but often excite fluorescence, which can mask the spectrum. Longer wavelengths such as 785 nm or 1064 nm reduce fluorescence but lower signal intensity and require longer integration. The choice depends on the sample.
Yes, when a reference spectral library is available and the sample is not strongly fluorescent. The measured spectrum is compared against library entries and ranked by match quality. Reported identifications should be confirmed with a second method or by the peak-by-peak comparison of a certified reference.
Concentration is usually measured with a UV-Vis spectrophotometer, because absorbance follows the Beer–Lambert law and many compounds absorb strongly in the ultraviolet. Fluorescence spectrometers offer lower detection limits for fluorescent analytes. The correct choice depends on the analyte, matrix and required limit of detection.
Spectral resolution is the smallest wavelength difference the instrument can separate, set by slit width, grating and detector. Higher resolution distinguishes closely spaced bands and sharp peaks but reduces light throughput. Choose resolution that matches the narrowest feature the method must resolve.
Yes. Wavelength accuracy drifts with lamp ageing, mechanical change and temperature. Calibration uses emission lines from deuterium or mercury lamps, or certified reference filters, and is verified against defined tolerances. Records of wavelength, photometric and stray-light checks support traceability.