Chemiluminescence Microplate Reader
化学发光酶标仪
- SKU CLI-0003
- CLIA Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA registration for research use (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Detection | Photomultiplier tube, photon counting |
|---|---|
| Dynamic range | Typically 6 orders of magnitude |
| Sensitivity | Detection limit in the low femtomole range |
| Cross-talk | < 0.1 % between adjacent wells |
| Plate formats | 96-well and strip plates, 384-well optional |
| Integration time | 0.1–10 s per well programmable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP15
What is the Chemiluminescence Microplate Reader?
A chemiluminescence microplate reader measures the light emitted from 96-well or strip plates in which a luminescent reaction has occurred, without needing a light source. It suits laboratories that use plate-based chemiluminescent kits or develop their own luminescent assays.
What is the Chemiluminescence Microplate Reader?
A chemiluminescence microplate reader measures the light emitted from 96-well or strip plates in which a luminescent reaction has occurred, without needing a light source. It suits laboratories that use plate-based chemiluminescent kits or develop their own luminescent assays.
Overview
Because the reaction itself emits light, the reader needs no lamp or filters: it places the plate in a light-tight chamber and counts photons with a photomultiplier tube, often sequentially well by well or with an imaging detector for the whole plate. The chamber must exclude ambient light completely, and crosstalk between adjacent wells must be controlled by well design and optics. Sensitivity depends on the detector and on the integration time, which is programmable from under a second to several seconds per well. The software reads glow or flash reactions, applies calibration curves and can perform dual-reagent injection if an injector module is fitted, which is useful for flash chemiluminescence where the light signal decays quickly. Plate-based luminescence also supports cell-based reporter assays and ATP measurements in research settings.
How does it work?
In chemiluminescence immunoassay the label is a molecule, often an acridinium ester or a luminol derivative, that emits light when triggered by an oxidant or a catalyst. Capture antibody or antigen is immobilised on magnetic particles, a well or a tube. After sample binding and washing, the labelled detection reagent forms a sandwich or competes with the analyte, and a trigger solution initiates the light-emitting reaction. A photomultiplier tube measures the light flash, which is integrated over a fixed interval, and the signal is converted into concentration using a calibration curve, usually a four-parameter logistic or a master curve with a lot-specific adjustment. Because light emission is measured against a dark background rather than as a difference between two absorbance values, chemiluminescence gives a wider dynamic range and better sensitivity than chromogenic enzyme immunoassay, and magnetic separation simplifies washing and automation.
What are the key features?
- Light-tight chamber with photomultiplier tube detection
- Programmable integration time per well from 0.1 to 10 s
- Glow and flash chemiluminescence measurement modes
- Optional dual injectors for trigger and substrate addition
- Low crosstalk between adjacent wells
- Plate-based reporter gene and ATP assay support
What are the technical specifications?
A typical chemiluminescence microplate reader configuration offers detection of Photomultiplier tube, photon counting, dynamic range of Typically 6 orders of magnitude, sensitivity of Detection limit in the low femtomole range, cross-talk of < 0.1 % between adjacent wells, plate formats of 96-well and strip plates, 384-well optional and integration time of 0.1–10 s per well programmable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Chemiluminescence Microplate Reader is used in plate-based chemiluminescent immunoassays, reporter gene assays in research, ATP and viability measurement and luminescence-based binding studies. Across the wider CLIA Analyzers class, laboratories also deploy it for hormone and fertility testing, cardiac marker measurement in emergency care and tumour marker monitoring.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP15, CLSI EP17, CLSI I/LA20, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA registration for research use; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the analyzer on a stable bench with controlled temperature and humidity, a grounded power supply and space for reagent and waste containers. Verify performance at installation with precision, linearity and method comparison studies for every assay you will report, following CLSI EP05, EP15 and EP17 where detection limits are relevant. Establish calibration and control intervals per assay and document the curve validity period. Daily work includes checking reagent volumes and waste, running controls and reviewing the calibration status; trigger solutions and wash buffers must be prepared or replaced as specified because deteriorated solutions cause erratic light signals. Replace tubing, syringes and photodetector-related parts on schedule, and treat all samples, controls and liquid waste as biohazardous.
How do I select the right Chemiluminescence Microplate Reader?
Specify a plate luminescence reader when your assays are plate-based and you do not need the random-access automation of a full immunoassay analyzer. In the RFQ confirm the sensitivity specification, crosstalk, whether injectors are available, and the software support for the curve models and cut-off calculations your kits use.
How does it compare with other CLIA Analyzers variants?
Select a CLIA analyzer from the assay menu first, because registration of each test with the platform is the decisive constraint, then size throughput from daily and peak-hour demand plus about thirty percent headroom. Check the first-result time for emergency markers such as troponin and beta-hCG, since several platforms need twenty to thirty minutes. Compare sensitivity and linear range for the analytes that matter to your clinical service, the sample volume per test, and the calibration stability, which determines how often curves must be rebuilt. Decide between magnetic bead, coated tube and microplate formats according to menu size and acceptable hands-on time. Confirm onboard reagent capacity, refrigeration, STAT access, carryover control, LIS interface, and the availability of calibrators, controls and service support locally.
Full specifications
| Detection | Photomultiplier tube, photon counting |
|---|---|
| Dynamic range | Typically 6 orders of magnitude |
| Sensitivity | Detection limit in the low femtomole range |
| Cross-talk | < 0.1 % between adjacent wells |
| Plate formats | 96-well and strip plates, 384-well optional |
| Integration time | 0.1–10 s per well programmable |
| Injectors | Optional 1 or 2 reagent injectors |
| Reading time | About 30–90 s per 96-well plate with injectors |
| Interfaces | USB, LAN, RS-232 |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Plate-based chemiluminescent immunoassays
- Reporter gene assays in research
- ATP and viability measurement
- Luminescence-based binding studies
Key features
- Light-tight chamber with photomultiplier tube detection
- Programmable integration time per well from 0.1 to 10 s
- Glow and flash chemiluminescence measurement modes
- Optional dual injectors for trigger and substrate addition
- Low crosstalk between adjacent wells
- Plate-based reporter gene and ATP assay support
Frequently asked questions about Chemiluminescence Microplate Reader
Only multi-mode instruments can, because fluorescence requires excitation optics and emission filters that a dedicated luminometer does not have. Laboratories that run both luminescent and fluorescent assays should specify a multi-mode reader rather than add a second dedicated instrument.
In flash chemiluminescence the light signal peaks within a second or two of reagent addition, so the reagent must be injected inside the dark chamber while the detector is already counting. Manual addition outside the reader gives lower and less reproducible signals.
Manufacturers use opaque plate materials, light guides or imaging optics with masking, and specify crosstalk as a percentage between adjacent wells. Laboratories should use white or black plates as recommended by the kit and avoid overfilling wells, which increases light spill.
Absolute light measurement is not usually required for immunoassays, so most instruments are checked with a reference light source or a luminescent standard rather than calibrated to a physical unit. Verification of sensitivity and linearity with such a standard should be documented at installation and annually.
Chemiluminescence measures light emission against a dark background, giving a wider measuring range and lower detection limits than the absorbance difference measured in ELISA. It also automates more easily because magnetic separation replaces repeated plate washing, though reagent and instrument costs are usually higher.
Most assays use a stored master curve with a lot-specific calibration that remains valid for two to four weeks, with a full curve required at each new reagent lot or after major maintenance. Daily control results confirm that the calibration remains acceptable, and any shift triggers recalibration before reporting.
At extremely high analyte concentrations both capture and detection antibodies become saturated and the signal falls, which can produce a falsely low result. Most analyzers detect this by diluting and re-measuring samples above a defined concentration or by comparing the reaction rate with expected curve behaviour.