Automated Chemiluminescence Immunoassay Analyzer

全自动化学发光免疫分析仪

  • SKU CLI-0001
  • CLIA Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Throughput120–240 tests/h
First-result time15–30 min
DetectionPhotomultiplier tube, flash chemiluminescence
SeparationMagnetic particle with automatic washing
Sample volume20–150 µL per test
Reagent positions24–40 refrigerated positions at 4–10 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP15

What is the Automated Chemiluminescence Immunoassay Analyzer?

An automated chemiluminescence immunoassay analyzer performs random-access testing with magnetic bead separation, photomultiplier detection and full reagent management. It suits hospital laboratories that need a broad menu of hormones, cardiac markers and infectious disease assays with walkaway operation.

What is the Automated Chemiluminescence Immunoassay Analyzer?

An automated chemiluminescence immunoassay analyzer performs random-access testing with magnetic bead separation, photomultiplier detection and full reagent management. It suits hospital laboratories that need a broad menu of hormones, cardiac markers and infectious disease assays with walkaway operation.

Overview

The analyzer aspirates sample and reagent into a reaction cuvette or tube, incubates the mixture, captures the immune complex on magnetic particles with a magnet, washes away unbound label and adds trigger solutions. A photomultiplier tube counts the emitted photons and the software reads concentration from a stored master curve adjusted for the reagent lot. Random access means any test combination can run in any order, and STAT samples are inserted ahead of routine work. Typical throughput is 120 to 240 tests per hour with a first result in fifteen to thirty minutes, and onboard refrigerated reagent positions allow several hours of operation. Calibration stability of two to four weeks, two or three levels of control per day, and full traceability of reagent lots and operator actions complete the platform.

How does it work?

In chemiluminescence immunoassay the label is a molecule, often an acridinium ester or a luminol derivative, that emits light when triggered by an oxidant or a catalyst. Capture antibody or antigen is immobilised on magnetic particles, a well or a tube. After sample binding and washing, the labelled detection reagent forms a sandwich or competes with the analyte, and a trigger solution initiates the light-emitting reaction. A photomultiplier tube measures the light flash, which is integrated over a fixed interval, and the signal is converted into concentration using a calibration curve, usually a four-parameter logistic or a master curve with a lot-specific adjustment. Because light emission is measured against a dark background rather than as a difference between two absorbance values, chemiluminescence gives a wider dynamic range and better sensitivity than chromogenic enzyme immunoassay, and magnetic separation simplifies washing and automation.

What are the key features?

  • Random access with STAT insertion ahead of routine work
  • Magnetic bead separation with automatic washing
  • Photomultiplier detection with wide dynamic range
  • Onboard refrigerated reagents with lot and expiry tracking
  • Stored master curve valid for two to four weeks per lot
  • Two or three levels of quality control per working day

What are the technical specifications?

A typical automated chemiluminescence immunoassay analyzer configuration offers throughput of 120–240 tests/h, first-result time of 15–30 min, detection of Photomultiplier tube, flash chemiluminescence, separation of Magnetic particle with automatic washing, sample volume of 20–150 µL per test and reagent positions of 24–40 refrigerated positions at 4–10 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Chemiluminescence Immunoassay Analyzer is used in hormone and thyroid testing, cardiac marker measurement, infectious disease serology and tumour marker monitoring. Across the wider CLIA Analyzers class, laboratories also deploy it for hormone and fertility testing, cardiac marker measurement in emergency care and tumour marker monitoring.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP15, CLSI EP17, CLSI I/LA20, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the analyzer on a stable bench with controlled temperature and humidity, a grounded power supply and space for reagent and waste containers. Verify performance at installation with precision, linearity and method comparison studies for every assay you will report, following CLSI EP05, EP15 and EP17 where detection limits are relevant. Establish calibration and control intervals per assay and document the curve validity period. Daily work includes checking reagent volumes and waste, running controls and reviewing the calibration status; trigger solutions and wash buffers must be prepared or replaced as specified because deteriorated solutions cause erratic light signals. Replace tubing, syringes and photodetector-related parts on schedule, and treat all samples, controls and liquid waste as biohazardous.

How do I select the right Automated Chemiluminescence Immunoassay Analyzer?

Specify this variant when the laboratory needs a broad immunoassay menu in random access with unattended operation. In the RFQ list the assays you intend to report and confirm their registration on the platform, then ask for throughput and first-result time on a realistic mix, reagent position count, calibration stability and the control material supply arrangement.

How does it compare with other CLIA Analyzers variants?

Select a CLIA analyzer from the assay menu first, because registration of each test with the platform is the decisive constraint, then size throughput from daily and peak-hour demand plus about thirty percent headroom. Check the first-result time for emergency markers such as troponin and beta-hCG, since several platforms need twenty to thirty minutes. Compare sensitivity and linear range for the analytes that matter to your clinical service, the sample volume per test, and the calibration stability, which determines how often curves must be rebuilt. Decide between magnetic bead, coated tube and microplate formats according to menu size and acceptable hands-on time. Confirm onboard reagent capacity, refrigeration, STAT access, carryover control, LIS interface, and the availability of calibrators, controls and service support locally.

Full specifications

Full specifications
Throughput120–240 tests/h
First-result time15–30 min
DetectionPhotomultiplier tube, flash chemiluminescence
SeparationMagnetic particle with automatic washing
Sample volume20–150 µL per test
Reagent positions24–40 refrigerated positions at 4–10 °C
Calibration stability14–28 days per reagent lot
Carryover< 0.1 % with disposable tips
InterfacesLAN with HL7 or ASTM two-way communication

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Hormone and thyroid testing
  • Cardiac marker measurement
  • Infectious disease serology
  • Tumour marker monitoring

Key features

  • Random access with STAT insertion ahead of routine work
  • Magnetic bead separation with automatic washing
  • Photomultiplier detection with wide dynamic range
  • Onboard refrigerated reagents with lot and expiry tracking
  • Stored master curve valid for two to four weeks per lot
  • Two or three levels of quality control per working day

Frequently asked questions about Automated Chemiluminescence Immunoassay Analyzer

The number of concurrent assays is limited by reagent positions and by incubation capacity, not by the software. Most analyzers handle ten to twenty different assays in one run, and laboratories with larger menus can schedule priorities or add a second reagent carousel if the platform allows.

Related models

All CLIA Analyzers

Request a quotation for the Automated Chemiluminescence Immunoassay Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote