Automated Microplate Washer for ELISA
自动洗板机
- SKU ELS-0002
- ELISA Systems
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Manifold channels | 8 or 12 channels, 96-well format |
|---|---|
| Residual volume | < 2–3 µL per well |
| Fill volume | 50–1000 µL programmable |
| Wash cycles | 1–20 programmable per run |
| Soak time | 0–60 s per cycle |
| Cross-contamination | < 0.1 % between wells |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI I/LA20
What is the Automated Microplate Washer for ELISA?
An automated microplate washer dispenses and aspirates wash buffer from the wells of a microplate under programmed control, removing unbound material between assay steps. It is essential for reproducible ELISA results and can also rinse plates for cell-based assays with the correct manifold.
What is the Automated Microplate Washer for ELISA?
An automated microplate washer dispenses and aspirates wash buffer from the wells of a microplate under programmed control, removing unbound material between assay steps. It is essential for reproducible ELISA results and can also rinse plates for cell-based assays with the correct manifold.
Overview
The washer primes wash buffer from a reservoir, dispenses it into each well through a manifold of 8 or 12 channels, soaks for a programmed time and then aspirates it through the same or a paired set of pins. Residual volume after aspiration is the key performance parameter and is usually specified below 2 to 3 microliters per well, with cross-contamination between wells kept low by separate dispense and aspirate lines. Programmable parameters include number of cycles, fill volume, soak time, aspiration position and shaking between cycles. Strip plate adapters handle 12-well strips, and overflow protection prevents flooding. Because unbound conjugate left in the well raises background, maintenance focuses on keeping the manifold pins clean, checking tube connections and replacing them when flow becomes uneven.
How does it work?
Enzyme-linked immunosorbent assay uses a plastic microplate whose wells carry a bound capture antibody or antigen. Sample is added, and any target present binds to the solid phase during incubation. After washing, a detection antibody conjugated to an enzyme such as horseradish peroxidase or alkaline phosphatase is added and binds to the captured target. A further wash removes unbound conjugate, then a substrate is added and the enzyme converts it into a coloured product. The reaction is stopped with acid or base and the absorbance is read at a defined wavelength, usually 450 nanometers with a reference wavelength between 600 and 650 nanometers. Absorbance is proportional to the amount of bound analyte, and a calibration curve, often four-parameter logistic, converts readings into concentrations or index values. Strict washing, incubation timing and temperature control determine the reliability of the result.
What are the key features?
- Manifold of 8 or 12 channels for 96-well and strip plates
- Programmable fill volume, soak time and number of cycles
- Residual volume below 2 to 3 microliters per well
- Separate dispense and aspirate lines to limit cross-contamination
- Overflow protection and adjustable aspiration height
- Strip adapters and plate shaking between cycles
What are the technical specifications?
A typical automated microplate washer for elisa configuration offers manifold channels of 8 or 12 channels, 96-well format, residual volume of < 2–3 µL per well, fill volume of 50–1000 µL programmable, wash cycles of 1–20 programmable per run, soak time of 0–60 s per cycle and cross-contamination of < 0.1 % between wells. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Microplate Washer for ELISA is used in ELISA plate washing between assay steps, ELISpot and cell-based assay rinsing, microplate-based research protocols and veterinary and food immunoassays. Across the wider ELISA Systems class, laboratories also deploy it for infectious disease serology, allergy specific IgE testing and autoimmune antibody screening.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI I/LA20, CLSI M29, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the reader and washer on a level bench away from vibration and direct light, and keep the plate carrier and optical window free of dust. Verify performance at installation with a reference dye plate for optical accuracy and with controls for each assay. Daily tasks include checking the washer manifold for blockage, priming the wash lines and running controls at two or three levels. Plates should be read immediately after stopping the reaction, since colour continues to develop and delays bias results, and consistent timing across the plate matters more than absolute speed. Replace tubing and manifold pins when flow becomes uneven, and dispose of wash waste and plates as biohazardous material.
How do I select the right Automated Microplate Washer for ELISA?
Specify this variant when you already have a reader and process plates manually or semi-automatically. In the RFQ state the plate and strip formats used, the residual volume specification and the cross-contamination figure, and whether soak time and multiple wash buffers are needed. Ask for the manifold type, since some assays require gentler aspiration to avoid cell loss.
How does it compare with other ELISA Systems variants?
Define the assays first, then decide how much automation is appropriate. Laboratories running fewer than one hundred wells per day can work with a reader and washer plus manual pipetting, while larger volumes justify an automated processor with plate handling, incubation and reporting. Compare readers by wavelength range, filter set, linearity, and whether they support kinetic and dual-wavelength measurement. For washers, check residual volume, the number of wash cycles programmable, and the manifolds for 96-well and strip formats. For automated systems, check plate capacity, walkaway time, whether the software handles assay protocols centrally, and the traceability of each step with lot numbers and operator identification. Confirm the assay registration status in your market, since ELISA kits are regulated separately from the instruments.
Full specifications
| Manifold channels | 8 or 12 channels, 96-well format |
|---|---|
| Residual volume | < 2–3 µL per well |
| Fill volume | 50–1000 µL programmable |
| Wash cycles | 1–20 programmable per run |
| Soak time | 0–60 s per cycle |
| Cross-contamination | < 0.1 % between wells |
| Plate formats | 96-well, 12-well strips, 384-well optional |
| Reservoir | 2–4 L buffer bottle with liquid level sensor |
| Interfaces | USB for protocol transfer; standalone keypad |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- ELISA plate washing between assay steps
- ELISpot and cell-based assay rinsing
- Microplate-based research protocols
- Veterinary and food immunoassays
Key features
- Manifold of 8 or 12 channels for 96-well and strip plates
- Programmable fill volume, soak time and number of cycles
- Residual volume below 2 to 3 microliters per well
- Separate dispense and aspirate lines to limit cross-contamination
- Overflow protection and adjustable aspiration height
- Strip adapters and plate shaking between cycles
Frequently asked questions about Automated Microplate Washer for ELISA
Any wash buffer left in the well dilutes the next reagent and retains unbound conjugate, which raises background and reduces precision. A residual volume of 2 to 3 microliters or less is generally acceptable, and the value should be verified periodically rather than assumed from the specification sheet.
Most models accept full 96-well plates and 12-well strips with an adapter, and the program selects which channels are active. Very deep or half-area plates may need different carriers, so confirm compatibility with the plates named in your assay kit instructions.
Use separate dispense and aspirate pins where available, keep the aspiration height adjusted so pins do not touch well contents, and avoid splashing during dispensing. Running a dye-based check across a plate shows whether contamination is uniform or confined to particular channels.
Rinse the lines with distilled water at the end of each session, inspect the manifold pins for residue or bending, and clean the aspiration system with the recommended solution weekly. Replace tubing and pins if flow becomes uneven, and store the washer with the lines free of buffer to avoid crystallisation.
A reader only measures absorbance after the assay has been performed manually, while an automated system also handles sample and reagent pipetting, incubation, washing, substrate addition and timing. Readers suit low volumes and flexible menus; automated systems reduce variability and labour at higher volumes.
Reading at the assay wavelength and subtracting a reference wavelength between 600 and 650 nanometers corrects for scratches, dust and bubbles on the plate. It reduces well-to-well variation and is standard practice for quantitative ELISA, especially at low absorbance values where optical artefacts have more influence.
Check the manifold for blocked or misaligned pins before each run, and verify residual volume weekly with a gravimetric or dye test. Uneven aspiration leaves wash solution that carries over unbound conjugate, which raises background and reduces precision, so any change in background should prompt a washer check.
Related models