High-Capacity Floor-Standing Clinical Centrifuge
大容量落地式临床离心机
- SKU CLC-0005
- Clinical Centrifuges
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 5,000 rpm |
|---|---|
| Maximum RCF | 4,500 × g (typical) |
| Capacity | 48–96 × 10 mL tubes |
| Rotor type | Swing-out, large bucket |
| Temperature range | 4–40 °C (refrigerated models) |
| Programs | Up to 50 programs |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-020, IEC 61010-1, ISO 15189
What is the High-Capacity Floor-Standing Clinical Centrifuge?
A high-capacity floor-standing clinical centrifuge holds 48 to over 100 blood collection tubes per run for central laboratories with heavy daily pre-analytical volume. It provides large-capacity swing-out rotors, optional refrigeration and adjustable acceleration profiles for continuous batch processing.
What is the High-Capacity Floor-Standing Clinical Centrifuge?
A high-capacity floor-standing clinical centrifuge holds 48 to over 100 blood collection tubes per run for central laboratories with heavy daily pre-analytical volume. It provides large-capacity swing-out rotors, optional refrigeration and adjustable acceleration profiles for continuous batch processing.
Overview
This variant uses a floor-standing cabinet with a bowl designed for large buckets, carrying 48, 72 or more 10 mL blood tubes, or 24 to 36 larger specimen containers. Maximum speed is typically 4,000 to 5,000 rpm with RCF of 3,500 to 4,500 × g. Refrigeration from 4 to 40 °C is optional. The microprocessor controller stores many programs for different tube types, with ramps to protect gel barriers. Automatic rotor recognition and imbalance sensing protect the drive, and a soft-close lid with lock prevents opening before the rotor stops. Some models include a mechanical rack loader or are sized for integration with pre-analytical lines. Weighing from 100 to 200 kg, the unit needs a solid floor, and steady airflow around ventilation openings.
How does it work?
A centrifuge replaces gravity with a much larger centrifugal force. A motor, usually a brushless induction or DC drive, spins a rotor holding sample tubes, and relative centrifugal force rises with the square of speed: RCF = 1.118 × 10⁻⁵ × r × rpm², where r is radius in centimeters. Heavier components such as red cells move to the tube bottom while serum or plasma stays above, often separated by a gel barrier that forms a solid layer during spinning. Swing-out rotors let tubes settle horizontally for a flat interface, while fixed-angle rotors shorten pelleting distance. Refrigerated models use a compressor to hold chamber temperature at 4 to 20 °C, and safety systems include lid locks, imbalance detection and overspeed protection. Programmable acceleration and braking profiles prevent remixing of separated layers.
What are the key features?
- Capacity of 48 to over 100 blood tubes per run
- Optional refrigeration from 4 to 40 °C
- Automatic rotor recognition and imbalance sensing
- Program memory for multiple tube types with ramp control
- Soft-close lid with lock until rotor stops
- Suitable for integration with pre-analytical lines
What are the technical specifications?
A typical high-capacity floor-standing clinical centrifuge configuration offers maximum speed of 5,000 rpm, maximum RCF of 4,500 × g (typical), capacity of 48–96 × 10 mL tubes, rotor type of Swing-out, large bucket, temperature range of 4–40 °C (refrigerated models) and programs of Up to 50 programs. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Capacity Floor-Standing Clinical Centrifuge is used in central laboratory high-volume processing, reference laboratory batch centrifugation, hospital blood sample centralized preparation and regional clinical testing centers. Across the wider Clinical Centrifuges class, laboratories also deploy it for serum and plasma separation, blood component preparation and microhematocrit determination.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-020, IEC 61010-1, ISO 15189, CLSI GP44, ISO 13485 and EN 12469. Certification candidates for this model are CE and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the centrifuge on a rigid level bench with clearance around it, and never run it unbalanced; opposite tubes must match within the tolerance stated in the manual. Use sealed buckets or aerosol-tight lids for infectious specimens. Verify speed with a photo-tachometer and temperature with a reference thermometer during installation and annually. Inspect rotors for cracks, corrosion and pitting, record run hours, and retire them at the manufacturer's service life. Clean with mild disinfectant, and clean the condenser of refrigerated models. Keep records under ISO 15189 and follow IEC 61010-2-020 safety requirements.
How do I select the right High-Capacity Floor-Standing Clinical Centrifuge?
Choose this variant when a bench centrifuge cannot keep up with peak tube volume, typically several hundred tubes per hour, or when a laboratory wants fewer runs per batch. In the RFQ specify maximum tube capacity, refrigeration, floor space, weight limits, rotor options and loading method. Confirm floor load capacity and lift access for delivery.
How does it compare with other Clinical Centrifuges variants?
Choose by sample type, tube format and temperature need. Routine serum or plasma separation in gel tubes needs a swing-out rotor reaching 3,000–4,000 rpm, roughly 1,500 to 2,200 × g, and a capacity matching peak hourly tube load. Blood bank and platelet work call for refrigeration at 20–24 °C or 4 °C and larger bucket capacity. Microhematocrit and cytospin tasks need purpose-built rotors. Check rotor and adapter compatibility with your tube diameters, maximum RCF, noise, footprint and programmability of acceleration and braking. Confirm lid lock and imbalance safety, biohazard containment with sealed buckets, and availability of spare rotors and service.
Full specifications
| Maximum speed | 5,000 rpm |
|---|---|
| Maximum RCF | 4,500 × g (typical) |
| Capacity | 48–96 × 10 mL tubes |
| Rotor type | Swing-out, large bucket |
| Temperature range | 4–40 °C (refrigerated models) |
| Programs | Up to 50 programs |
| Acceleration/braking | 10 levels each |
| Drive | Brushless induction motor |
| Noise level | ≤ 65 dB(A) |
| Weight | 100–200 kg |
| Power supply | 220 V AC, 50/60 Hz, 1.5–3 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Central laboratory high-volume processing
- Reference laboratory batch centrifugation
- Hospital blood sample centralized preparation
- Regional clinical testing centers
Key features
- Capacity of 48 to over 100 blood tubes per run
- Optional refrigeration from 4 to 40 °C
- Automatic rotor recognition and imbalance sensing
- Program memory for multiple tube types with ramp control
- Soft-close lid with lock until rotor stops
- Suitable for integration with pre-analytical lines
Frequently asked questions about High-Capacity Floor-Standing Clinical Centrifuge
Laboratories that process several hundred tubes per hour, or need to batch large runs within tight turnaround, benefit from floor-standing models. They suit hospital central laboratories and reference laboratories where pre-analytical capacity limits analyzer use.
Sensors detect vibration and stop the run if the load is unbalanced beyond tolerance, displaying an alarm. Users balance opposite buckets by weight, using water-filled tubes or adapters. Automatic rotor recognition prevents running at a speed not approved for the installed rotor.
Rotor and bucket ratings state a maximum load per bucket and total load, often 2 to 4 kg per bucket at maximum speed. Exceeding the rated load can damage the rotor and drive, so always check the load plate and tube weights.
It separates blood and other specimens by density. Typical uses are obtaining serum or plasma before analysis, packing red cells for hematocrit, preparing blood components in blood banks, and concentrating cells onto slides for cytology. It is a core pre-analytical instrument in laboratories.
Rpm is rotor speed in revolutions per minute, while RCF is the actual force on the sample, expressed in multiples of gravity. RCF depends on both speed and rotor radius, so protocols should state RCF in × g to give the same separation on different centrifuges.
Refrigeration limits heating from rotor friction and preserves temperature-sensitive analytes or cells. Blood bank platelet preparations are spun near 20–24 °C, while plasma and some hormone or enzyme samples are spun at 4 °C. Unrefrigerated units can warm by several degrees during long runs.