Brightfield Clinical Binocular Microscope
明场临床双目显微镜
- SKU CLM-0001
- Clinical Microscopy
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Observation method | Brightfield, transmitted light |
|---|---|
| Magnification | 40×–1,000× |
| Objectives | Plan achromat 4×/10×/40×/100× oil |
| Numerical aperture | 0.10 / 0.25 / 0.65 / 1.25 |
| Eyepieces | WF10×/20 mm |
| Head | Binocular, 30° inclined |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8039, ISO 10110, IEC 61010-1
What is the Brightfield Clinical Binocular Microscope?
A brightfield clinical binocular microscope illuminates stained specimens from below and is used for blood film differentials, Gram stains, acid-fast smears and tissue sections. Plan achromat objectives from 4× to 100× oil and LED illumination make it the routine workhorse of hospital laboratories.
What is the Brightfield Clinical Binocular Microscope?
A brightfield clinical binocular microscope illuminates stained specimens from below and is used for blood film differentials, Gram stains, acid-fast smears and tissue sections. Plan achromat objectives from 4× to 100× oil and LED illumination make it the routine workhorse of hospital laboratories.
Overview
This variant uses transmitted-light brightfield optics with infinity-corrected plan achromat objectives at 4×, 10×, 40× and 100× oil, typically with numerical apertures of 0.10, 0.25, 0.65 and 1.25. A siedentopf binocular head tilted at 30 degrees and adjustable interpupillary distance of 48 to 75 mm supports long viewing sessions, and WF10× eyepieces with field number 20 give a wide field. An Abbe condenser with iris diaphragm and a built-in LED source with intensity control provide Köhler-compatible illumination. A coaxial coarse and fine focus and a mechanical stage with 75 × 50 mm travel allow precise movement. LED lifespan exceeds 20,000 hours and produces little heat. Optional trinocular head and camera adapter support documentation.
How does it work?
A compound microscope forms an enlarged image in two stages. The objective lens creates a real intermediate image of the specimen, and the eyepiece magnifies it further, giving total magnification equal to objective power times eyepiece power, commonly 40× to 1,000×. A condenser focuses light from an LED or halogen source onto the specimen using Köhler illumination for even contrast. Phase-contrast optics convert small refractive index differences in live cells into intensity differences using a phase ring. Dark-field blocks direct light so only scattered light enters the objective, making thin organisms bright on dark background. Fluorescence microscopes use an excitation filter, dichroic mirror and emission filter to show fluorophore-labeled targets. Digital systems add a camera or scanner that captures images and stitches fields into whole slide images.
What are the key features?
- Infinity-corrected plan achromat objectives 4×, 10×, 40× and 100× oil
- Inclined binocular head with 48–75 mm interpupillary adjustment
- Built-in LED illumination with intensity control and long lifetime
- Abbe condenser with iris diaphragm for Köhler setting
- Coaxial coarse and fine focus with mechanical stage
- Optional trinocular port for camera documentation
What are the technical specifications?
A typical brightfield clinical binocular microscope configuration offers observation method of Brightfield, transmitted light, magnification of 40×–1,000×, objectives of Plan achromat 4×/10×/40×/100× oil, numerical aperture of 0.10 / 0.25 / 0.65 / 1.25, eyepieces of WF10×/20 mm and head of Binocular, 30° inclined. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Brightfield Clinical Binocular Microscope is used in blood film differential counts, gram and acid-fast smear screening, histology and cytology examination and teaching and training laboratories. Across the wider Clinical Microscopy class, laboratories also deploy it for blood film differential examination, urine sediment examination and microbiology smear examination.
Which standards and certifications apply?
Relevant standards and methods include ISO 8039, ISO 10110, IEC 61010-1, ISO 15189, ISO 19012-1 and ISO 19012-2. Certification candidates for this model are CE and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the microscope on a stable, vibration-free bench away from direct sunlight and dust, and use a cover when idle. Clean lenses only with lens tissue and approved solvent, and remove immersion oil after each use. Align Köhler illumination and verify parfocality at installation and after servicing. Calibrate eyepiece reticles or camera scale with a stage micrometer for measurements. Replace LED or halogen sources according to lifetime, and inspect objectives for scratches and fungus in humid climates. Staff should observe ergonomic posture and breaks. For digital systems, validate image quality and storage integrity in line with laboratory procedures under ISO 15189.
How do I select the right Brightfield Clinical Binocular Microscope?
Select this variant for routine stained-smear work in hematology, microbiology and pathology when no phase-contrast or fluorescence is needed. In the RFQ specify the objective set and numerical apertures, eyepiece field number, head type, illumination type and life, stage travel, and whether a camera port is needed. Request parfocal and infinity-corrected optics.
How does it compare with other Clinical Microscopy variants?
Choose the microscope by specimen type and contrast technique. Brightfield with plan achromat objectives suits stained blood films, Gram stains and histology. Phase contrast is preferred for unstained urine sediment, semen and live cell culture. Dark-field suits spirochetes such as Treponema pallidum, and fluorescence suits auramine acid-fast screening and immunofluorescence. Check objective quality, numerical aperture, field number, stage mechanics, illumination life and whether a camera port or digital system is needed for documentation and telepathology. Consider ergonomic features such as tilting binocular heads and low stage height for long screening sessions, and confirm objective parfocality and availability of spare lamps and service support.
Full specifications
| Observation method | Brightfield, transmitted light |
|---|---|
| Magnification | 40×–1,000× |
| Objectives | Plan achromat 4×/10×/40×/100× oil |
| Numerical aperture | 0.10 / 0.25 / 0.65 / 1.25 |
| Eyepieces | WF10×/20 mm |
| Head | Binocular, 30° inclined |
| Interpupillary distance | 48–75 mm |
| Condenser | Abbe NA 1.25 with iris |
| Illumination | LED, 3–5 W, adjustable |
| Stage travel | 75 × 50 mm |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Blood film differential counts
- Gram and acid-fast smear screening
- Histology and cytology examination
- Teaching and training laboratories
Key features
- Infinity-corrected plan achromat objectives 4×, 10×, 40× and 100× oil
- Inclined binocular head with 48–75 mm interpupillary adjustment
- Built-in LED illumination with intensity control and long lifetime
- Abbe condenser with iris diaphragm for Köhler setting
- Coaxial coarse and fine focus with mechanical stage
- Optional trinocular port for camera documentation
Frequently asked questions about Brightfield Clinical Binocular Microscope
Immersion oil has a refractive index of about 1.515, close to glass, so light is not refracted away between the slide and objective. This allows a numerical aperture of 1.25 and resolves fine detail such as bacterial morphology and blood cell inclusions.
A binocular head lets the observer use both eyes, reducing eye strain and fatigue during extended screening such as differential counts or cytology. Adjustable interpupillary distance and diopter settings allow each user to set a comfortable, well-focused view.
Yes. LED sources give stable color temperature near 5,000 to 6,000 K, low heat and lifetimes above 20,000 hours. Intensity is adjustable without color shift, and staining appearance on blood films and Gram stains is comparable to halogen when a daylight filter is used.
It is used to examine specimens under magnification for diagnosis, including blood cell morphology, urine sediment, parasites, bacteria in stained smears, cytology and tissue sections. Different microscope types provide brightfield, phase-contrast, dark-field or fluorescence contrast for different specimens.
Standard objectives are 4×, 10×, 40× and 100× oil immersion, paired with 10× eyepieces to give 40× to 1,000× total magnification. Low power locates fields, 40× is used for urine sediment and cytology, and 100× oil is used for blood films and bacterial morphology.
Köhler illumination is a method of adjusting the field and condenser apertures so the specimen is evenly lit and glare is minimized. It gives maximum resolution and contrast from the objective, and should be set after installing or moving the microscope and when changing objectives.