Refrigerated Blood Bank Centrifuge
冷冻血库离心机
- SKU CLC-0002
- Clinical Centrifuges
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum speed | 5,000 rpm |
|---|---|
| Maximum RCF | 6,000 × g (typical) |
| Temperature range | −10 to 40 °C |
| Temperature accuracy | ±1 °C |
| Capacity | 6 × 500 mL bags or 4 × 1,000 mL |
| Rotor type | Swing-out with bag buckets |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-2-020, IEC 61010-1, ISO 15189
What is the Refrigerated Blood Bank Centrifuge?
A refrigerated blood bank centrifuge spins blood bags and large-volume tubes at controlled temperature, usually 4 °C to 22 °C, to separate red cells, plasma and platelets. Blood banks, transfusion services and plasma laboratories use it for component preparation and crossmatch testing.
What is the Refrigerated Blood Bank Centrifuge?
A refrigerated blood bank centrifuge spins blood bags and large-volume tubes at controlled temperature, usually 4 °C to 22 °C, to separate red cells, plasma and platelets. Blood banks, transfusion services and plasma laboratories use it for component preparation and crossmatch testing.
Overview
This variant uses a compressor-refrigerated chamber with a temperature range of about −10 to 40 °C and accuracy within ±1 °C, allowing runs at 20–24 °C for platelet-rich plasma or 4 °C for red cell and plasma separation. Large swing-out buckets hold standard blood bags or multiple 50 to 500 mL containers, and speeds reach 4,000 to 5,000 rpm with RCF up to 4,500 to 6,000 × g. Programmable multi-step protocols include soft spin for platelet-rich plasma and hard spin for platelet concentrate, each with controlled ramp and braking. Imbalance detection, lid lock and overspeed protection are standard. Some models provide bag balancing aids and a printed or digital run record for batch traceability in transfusion service quality systems.
How does it work?
A centrifuge replaces gravity with a much larger centrifugal force. A motor, usually a brushless induction or DC drive, spins a rotor holding sample tubes, and relative centrifugal force rises with the square of speed: RCF = 1.118 × 10⁻⁵ × r × rpm², where r is radius in centimeters. Heavier components such as red cells move to the tube bottom while serum or plasma stays above, often separated by a gel barrier that forms a solid layer during spinning. Swing-out rotors let tubes settle horizontally for a flat interface, while fixed-angle rotors shorten pelleting distance. Refrigerated models use a compressor to hold chamber temperature at 4 to 20 °C, and safety systems include lid locks, imbalance detection and overspeed protection. Programmable acceleration and braking profiles prevent remixing of separated layers.
What are the key features?
- Compressor refrigeration from −10 to 40 °C with ±1 °C accuracy
- Large buckets for blood bags and 50–500 mL containers
- Programmable soft-spin and hard-spin component protocols
- Speeds up to 5,000 rpm and RCF up to 6,000 × g
- Run record output for batch traceability
- Imbalance, lid lock and overspeed protection
What are the technical specifications?
A typical refrigerated blood bank centrifuge configuration offers maximum speed of 5,000 rpm, maximum RCF of 6,000 × g (typical), temperature range of −10 to 40 °C, temperature accuracy of ±1 °C, capacity of 6 × 500 mL bags or 4 × 1,000 mL and rotor type of Swing-out with bag buckets. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Refrigerated Blood Bank Centrifuge is used in blood component separation, platelet concentrate preparation, transfusion service crossmatch and plasma collection centers. Across the wider Clinical Centrifuges class, laboratories also deploy it for serum and plasma separation, blood component preparation and microhematocrit determination.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-2-020, IEC 61010-1, ISO 15189, CLSI GP44, ISO 13485 and EN 12469. Certification candidates for this model are CE and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the centrifuge on a rigid level bench with clearance around it, and never run it unbalanced; opposite tubes must match within the tolerance stated in the manual. Use sealed buckets or aerosol-tight lids for infectious specimens. Verify speed with a photo-tachometer and temperature with a reference thermometer during installation and annually. Inspect rotors for cracks, corrosion and pitting, record run hours, and retire them at the manufacturer's service life. Clean with mild disinfectant, and clean the condenser of refrigerated models. Keep records under ISO 15189 and follow IEC 61010-2-020 safety requirements.
How do I select the right Refrigerated Blood Bank Centrifuge?
Choose this variant when preparing blood components in bags or when temperature control between 4 and 24 °C is a requirement. In the RFQ specify bag size and count, programmed spin protocols, temperature range and accuracy, run record format and whether bucket balancing accessories are needed. Ask for temperature qualification data.
How does it compare with other Clinical Centrifuges variants?
Choose by sample type, tube format and temperature need. Routine serum or plasma separation in gel tubes needs a swing-out rotor reaching 3,000–4,000 rpm, roughly 1,500 to 2,200 × g, and a capacity matching peak hourly tube load. Blood bank and platelet work call for refrigeration at 20–24 °C or 4 °C and larger bucket capacity. Microhematocrit and cytospin tasks need purpose-built rotors. Check rotor and adapter compatibility with your tube diameters, maximum RCF, noise, footprint and programmability of acceleration and braking. Confirm lid lock and imbalance safety, biohazard containment with sealed buckets, and availability of spare rotors and service.
Full specifications
| Maximum speed | 5,000 rpm |
|---|---|
| Maximum RCF | 6,000 × g (typical) |
| Temperature range | −10 to 40 °C |
| Temperature accuracy | ±1 °C |
| Capacity | 6 × 500 mL bags or 4 × 1,000 mL |
| Rotor type | Swing-out with bag buckets |
| Programs | Up to 99 programs, multi-step |
| Acceleration/braking | 10 levels each |
| Drive | Brushless induction motor |
| Display | Touchscreen or LCD |
| Power supply | 220 V AC, 50/60 Hz, 1.5–2.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Blood component separation
- Platelet concentrate preparation
- Transfusion service crossmatch
- Plasma collection centers
Key features
- Compressor refrigeration from −10 to 40 °C with ±1 °C accuracy
- Large buckets for blood bags and 50–500 mL containers
- Programmable soft-spin and hard-spin component protocols
- Speeds up to 5,000 rpm and RCF up to 6,000 × g
- Run record output for batch traceability
- Imbalance, lid lock and overspeed protection
Frequently asked questions about Refrigerated Blood Bank Centrifuge
Blood components must be spun at defined temperatures to preserve function: platelets near 20–24 °C to avoid cold activation, red cell and plasma separation at 4 °C to slow metabolism. Refrigerated chambers also counter heat from rotor friction during high-speed runs.
Soft-spin protocols commonly use about 1,000 to 1,500 × g for 10 to 15 minutes to leave platelets suspended in plasma, followed by a harder spin of about 3,000 to 5,000 × g to pellet platelets. Exact values follow the validated local procedure.
Pre-cooling the chamber for 15 to 30 minutes at the target temperature with the rotor installed gives stable conditions before loading bags. Many models have a pre-cool function, and the temperature should be checked against a reference thermometer during qualification.
It separates blood and other specimens by density. Typical uses are obtaining serum or plasma before analysis, packing red cells for hematocrit, preparing blood components in blood banks, and concentrating cells onto slides for cytology. It is a core pre-analytical instrument in laboratories.
Rpm is rotor speed in revolutions per minute, while RCF is the actual force on the sample, expressed in multiples of gravity. RCF depends on both speed and rotor radius, so protocols should state RCF in × g to give the same separation on different centrifuges.
Refrigeration limits heating from rotor friction and preserves temperature-sensitive analytes or cells. Blood bank platelet preparations are spun near 20–24 °C, while plasma and some hormone or enzyme samples are spun at 4 °C. Unrefrigerated units can warm by several degrees during long runs.