Benchtop Automated Biochemistry Analyzer
台式全自动生化分析仪
- SKU CLA-0001
- Clinical Analyzers
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
- NMPA registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 200–400 tests/h (photometric) |
|---|---|
| Test principle | Colorimetry, turbidimetry, enzyme kinetics |
| Wavelength range | 340–800 nm, 8–12 wavelengths |
| Sample volume | 1.5–35 µL per test |
| Reagent volume | 20–300 µL per test |
| Reaction temperature | 37 ± 0.1 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05-A3, CLSI EP06
What is the Benchtop Automated Biochemistry Analyzer?
A benchtop automated biochemistry analyzer is a random-access photometric system that runs routine serum chemistry without operator intervention between loading and result. It suits clinics and mid-size hospital laboratories processing roughly 100 to 400 tests per hour, where space and budget are limited.
What is the Benchtop Automated Biochemistry Analyzer?
A benchtop automated biochemistry analyzer is a random-access photometric system that runs routine serum chemistry without operator intervention between loading and result. It suits clinics and mid-size hospital laboratories processing roughly 100 to 400 tests per hour, where space and budget are limited.
Overview
This variant places a full photometric chemistry system on a bench footprint of about one square meter. A sample probe and one or two reagent probes with liquid-level detection dispense microliter volumes into a rotating reaction disc kept at 37 °C. A grating photometer reads absorbance at multiple wavelengths, typically 340 to 800 nm, so that enzymatic, colorimetric and turbidimetric immunoassay tests can all run on one unit. The software handles multi-point calibration, Levey-Jennings quality control, reagent inventory tracking and automatic rerun with dilution when results exceed linearity. Open reagent channels let the laboratory use third-party kits. Throughput is lower than floor-standing systems, but the lower purchase cost, reduced water and reagent consumption and simple maintenance make it the default choice for routine chemistry panels.
How does it work?
Most clinical analyzers quantify an analyte by converting its concentration into a measurable signal. Photometric analyzers mix sample with reagent in a reaction cuvette, hold it at 37 °C, and measure absorbance at selected wavelengths through a grating or filter wheel; concentration follows the Beer–Lambert relation against a calibration curve. Ion-selective electrode modules measure the potential of Na+, K+ and Cl- across a selective membrane relative to a reference electrode. Turbidimetric and nephelometric modules detect light scattered by antigen-antibody complexes. Chromatographic analyzers separate hemoglobin fractions by cation-exchange HPLC. Key components include a sample and reagent probe with liquid-level detection, a precision syringe, a thermostatted reaction unit, a detection optic, and software that applies calibration, quality control rules and result flagging.
What are the key features?
- Random-access sample and reagent loading with STAT priority
- Grating photometer covering 340–800 nm with 8 to 12 wavelengths
- Reaction disc with temperature control at 37 °C
- Open reagent channels for third-party kits
- Automatic dilution and rerun for over-range results
- Barcode reading for samples and reagents with LIS interface
What are the technical specifications?
A typical benchtop automated biochemistry analyzer configuration offers throughput of 200–400 tests/h (photometric), test principle of Colorimetry, turbidimetry, enzyme kinetics, wavelength range of 340–800 nm, 8–12 wavelengths, sample volume of 1.5–35 µL per test, reagent volume of 20–300 µL per test and reaction temperature of 37 ± 0.1 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Automated Biochemistry Analyzer is used in hospital clinical chemistry laboratories, community health centers, private diagnostic laboratories and physical examination centers. Across the wider Clinical Analyzers class, laboratories also deploy it for routine serum chemistry, electrolyte and blood gas testing and diabetes monitoring (HbA1c).
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05-A3, CLSI EP06, CLSI C24, IEC 61010-2-101 and IEC 61010-1. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install on a level bench away from direct sunlight, vibration and strong electromagnetic sources, with stable power, a dedicated earth and a supply of purified water that meets CLSI Type II quality where the analyzer requires it. Verify performance before clinical use through precision, linearity, carryover and method comparison studies in line with CLSI EP protocols. Run internal quality control every day and join an external quality assessment scheme. Schedule daily probe cleaning, weekly lamp and cuvette checks, and replacement of tubing, syringes and lamps per the maintenance plan. Treat all samples and waste as biohazardous and follow local regulations for disposal.
How do I select the right Benchtop Automated Biochemistry Analyzer?
Select this variant when daily chemistry volume is about 300 to 2,000 tests and a floor-standing system cannot be justified. In the RFQ specify tests per hour, required menu, number of open channels, sample volume range for pediatric use, deionized water consumption and LIS protocol. Compare with semi-automated units if volume is below 100 tests per day.
How does it compare with other Clinical Analyzers variants?
Start with the test menu and daily workload, because throughput and reagent format set the platform. Low volumes of routine chemistry suit a semi-automated photometer, while several hundred samples a day call for a benchtop random-access analyzer. Decide whether you need open reagent channels, which lower cost per test but require you to validate each assay, or closed reagent systems that simplify operation. Check sample volume needs for pediatric work, onboard reagent capacity, cuvette type and waste handling. For electrolytes, blood gas or HbA1c, choose a dedicated analyzer rather than stretching a general chemistry unit. Confirm LIS connectivity through HL7 or ASTM, barcode reading, and the availability of service engineers and spare parts in your region.
Full specifications
| Throughput | 200–400 tests/h (photometric) |
|---|---|
| Test principle | Colorimetry, turbidimetry, enzyme kinetics |
| Wavelength range | 340–800 nm, 8–12 wavelengths |
| Sample volume | 1.5–35 µL per test |
| Reagent volume | 20–300 µL per test |
| Reaction temperature | 37 ± 0.1 °C |
| Reaction cuvette | Reusable, optical path 5 mm |
| Sample positions | 60–90 positions |
| Reagent positions | 40–80 positions, refrigerated 2–8 °C |
| Interface | RS-232/USB, HL7/ASTM via LIS |
| Power supply | 220 V AC, 50/60 Hz, 600–1000 VA |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Hospital clinical chemistry laboratories
- Community health centers
- Private diagnostic laboratories
- Physical examination centers
Key features
- Random-access sample and reagent loading with STAT priority
- Grating photometer covering 340–800 nm with 8 to 12 wavelengths
- Reaction disc with temperature control at 37 °C
- Open reagent channels for third-party kits
- Automatic dilution and rerun for over-range results
- Barcode reading for samples and reagents with LIS interface
Frequently asked questions about Benchtop Automated Biochemistry Analyzer
Benchtop random-access chemistry analyzers typically run 200 to 400 photometric tests per hour, and up to about 560 tests per hour when a combined ISE module is fitted. Actual throughput depends on the test mix, incubation times and whether dual reagent assays are used.
Yes, where open channels are provided. Assay parameters such as wavelength, volumes, incubation and calibration type are programmed, then verified with control materials and patient comparison before clinical use. The laboratory carries responsibility for validating each third-party assay.
Most analyzers need purified water meeting CLSI Type II specification, with resistivity above about 1 MΩ·cm, for reaction cuvette washing and dilution. Consumption is typically 10 to 30 liters per hour depending on wash cycles. A dedicated water purification unit is commonly recommended.
A clinical analyzer measures concentrations of substances such as glucose, enzymes, electrolytes, lipids and proteins in patient samples. Results support diagnosis, treatment decisions and monitoring in hospitals, clinics and reference laboratories. Different platforms cover chemistry, electrolytes, blood gases, specific proteins and HbA1c.
An open system accepts reagents from any supplier once channel parameters are programmed and validated, which gives flexibility and lower cost per test. A closed system uses reagents supplied for that platform with pre-set parameters and barcodes, which simplifies operation but limits supplier choice.
Calibration frequency depends on the assay and reagent lot. Many photometric tests are recalibrated at each new reagent lot, after major maintenance, or when quality control shifts beyond limits. Electrolyte electrodes are typically calibrated automatically every few hours. Follow the reagent instructions for use and your laboratory procedure.