Skip to main content
Lab Manufacturers China
Blood Gas and Electrolyte Analyzer — product photo

Blood Gas and Electrolyte Analyzer

血气电解质分析仪

  • SKU CLA-0003
  • Clinical Analyzers
  • CE (to be confirmed)
  • ISO 13485 quality system (to be confirmed)
  • NMPA registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measured parameterspH, pCO2, pO2, Na+, K+, Ca2+, Cl-, Hct, Glu, Lac
pH range6.500–8.000
pCO2 range5–200 mmHg
pO2 range0–800 mmHg
Sample volume65–100 µL
Analysis time60–120 s
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05-A3, CLSI EP06

What is the Blood Gas and Electrolyte Analyzer?

A blood gas and electrolyte analyzer measures pH, pCO2, pO2 and electrolytes in whole blood using electrochemical sensors, typically with added hematocrit, glucose and lactate. It is used in intensive care, operating rooms and emergency departments where critical results are needed within minutes at the point of care.

What is the Blood Gas and Electrolyte Analyzer?

A blood gas and electrolyte analyzer measures pH, pCO2, pO2 and electrolytes in whole blood using electrochemical sensors, typically with added hematocrit, glucose and lactate. It is used in intensive care, operating rooms and emergency departments where critical results are needed within minutes at the point of care.

Overview

Sensors in a thermostatted measuring chamber at 37 °C measure whole blood from a 65 to 100 µL sample. pH and reference use glass or polymer membrane electrodes, pCO2 uses a Severinghaus-type electrode, pO2 uses an amperometric Clark electrode, and Na+, K+, Ca2+ and Cl- use ion-selective membranes. Hematocrit is determined by conductivity, while glucose and lactate use enzyme-coated amperometric electrodes. Calibration with two-point gas and liquid standards runs automatically at set intervals, and some systems use single-use sensor cartridges that combine sensors, reagents and waste. The analyzer calculates derived values such as bicarbonate, base excess and oxygen saturation with temperature correction, and accepts syringe, capillary and, on some models, ampoule samples. Turnaround is usually 60 to 120 seconds.

How does it work?

Most clinical analyzers quantify an analyte by converting its concentration into a measurable signal. Photometric analyzers mix sample with reagent in a reaction cuvette, hold it at 37 °C, and measure absorbance at selected wavelengths through a grating or filter wheel; concentration follows the Beer–Lambert relation against a calibration curve. Ion-selective electrode modules measure the potential of Na+, K+ and Cl- across a selective membrane relative to a reference electrode. Turbidimetric and nephelometric modules detect light scattered by antigen-antibody complexes. Chromatographic analyzers separate hemoglobin fractions by cation-exchange HPLC. Key components include a sample and reagent probe with liquid-level detection, a precision syringe, a thermostatted reaction unit, a detection optic, and software that applies calibration, quality control rules and result flagging.

What are the key features?

  • Measures pH, pCO2, pO2, Na+, K+, Ca2+ and Cl- from one whole blood sample
  • Optional hematocrit, glucose and lactate channels
  • Automatic two-point calibration and quality control
  • Sample volume of 65–100 µL with 60–120 s turnaround
  • Calculated parameters including HCO3-, BE and sO2 with temperature correction
  • Cartridge-based reagent pack with onboard waste container

What are the technical specifications?

A typical blood gas and electrolyte analyzer configuration offers measured parameters of pH, pCO2, pO2, Na+, K+, Ca2+, Cl-, Hct, Glu, Lac, pH range of 6.500–8.000, pCO2 range of 5–200 mmHg, pO2 range of 0–800 mmHg, sample volume of 65–100 µL and analysis time of 60–120 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Blood Gas and Electrolyte Analyzer is used in intensive care units, operating rooms and anesthesia, emergency departments and neonatal and respiratory care. Across the wider Clinical Analyzers class, laboratories also deploy it for routine serum chemistry, electrolyte and blood gas testing and diabetes monitoring (HbA1c).

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, CLSI EP05-A3, CLSI EP06, CLSI C24, IEC 61010-2-101 and IEC 61010-1. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install on a level bench away from direct sunlight, vibration and strong electromagnetic sources, with stable power, a dedicated earth and a supply of purified water that meets CLSI Type II quality where the analyzer requires it. Verify performance before clinical use through precision, linearity, carryover and method comparison studies in line with CLSI EP protocols. Run internal quality control every day and join an external quality assessment scheme. Schedule daily probe cleaning, weekly lamp and cuvette checks, and replacement of tubing, syringes and lamps per the maintenance plan. Treat all samples and waste as biohazardous and follow local regulations for disposal.

How do I select the right Blood Gas and Electrolyte Analyzer?

Select this variant when fast arterial or venous blood gas results are needed at the bedside or in a satellite laboratory. In the RFQ specify the parameter panel, sample volume, sensor or cartridge life, daily sample load, calibration gas supply and LIS or POCT connectivity. A general chemistry analyzer cannot replace it.

How does it compare with other Clinical Analyzers variants?

Start with the test menu and daily workload, because throughput and reagent format set the platform. Low volumes of routine chemistry suit a semi-automated photometer, while several hundred samples a day call for a benchtop random-access analyzer. Decide whether you need open reagent channels, which lower cost per test but require you to validate each assay, or closed reagent systems that simplify operation. Check sample volume needs for pediatric work, onboard reagent capacity, cuvette type and waste handling. For electrolytes, blood gas or HbA1c, choose a dedicated analyzer rather than stretching a general chemistry unit. Confirm LIS connectivity through HL7 or ASTM, barcode reading, and the availability of service engineers and spare parts in your region.

Full specifications

Full specifications
Measured parameterspH, pCO2, pO2, Na+, K+, Ca2+, Cl-, Hct, Glu, Lac
pH range6.500–8.000
pCO2 range5–200 mmHg
pO2 range0–800 mmHg
Sample volume65–100 µL
Analysis time60–120 s
Measuring temperature37 °C
Sample typesWhole blood (syringe, capillary)
Sensor life30–90 days, parameter dependent
Data storage5,000–10,000 results
InterfaceUSB, Ethernet, HL7/POCT1-A

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Intensive care units
  • Operating rooms and anesthesia
  • Emergency departments
  • Neonatal and respiratory care

Key features

  • Measures pH, pCO2, pO2, Na+, K+, Ca2+ and Cl- from one whole blood sample
  • Optional hematocrit, glucose and lactate channels
  • Automatic two-point calibration and quality control
  • Sample volume of 65–100 µL with 60–120 s turnaround
  • Calculated parameters including HCO3-, BE and sO2 with temperature correction
  • Cartridge-based reagent pack with onboard waste container

Frequently asked questions about Blood Gas and Electrolyte Analyzer

It is designed for heparinized whole blood from arterial, venous or capillary sources. Samples should be collected in balanced-heparin syringes, free of air bubbles, and analyzed within 15 minutes at room temperature to avoid changes in pO2, pH and lactate caused by ongoing cell metabolism.

Request a quotation for the Blood Gas and Electrolyte Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote