HbA1c Glycohemoglobin Analyzer
糖化血红蛋白分析仪
- SKU CLA-0005
- Clinical Analyzers
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
- NMPA registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Method | Cation-exchange HPLC |
|---|---|
| Analysis time | ~1–2 min per sample |
| Measuring range | HbA1c 3.0–20.0 % (9–195 mmol/mol) |
| Precision | CV ≤ 2 % (typical) |
| Sample volume | 5–20 µL whole blood |
| Detection wavelength | 415 nm and 690 nm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05-A3, CLSI EP06
What is the HbA1c Glycohemoglobin Analyzer?
An HbA1c glycohemoglobin analyzer quantifies glycated hemoglobin in whole blood, most commonly by cation-exchange HPLC, to monitor average blood glucose control over the preceding two to three months. It is used in diabetes clinics, hospital laboratories and large population screening programs.
What is the HbA1c Glycohemoglobin Analyzer?
An HbA1c glycohemoglobin analyzer quantifies glycated hemoglobin in whole blood, most commonly by cation-exchange HPLC, to monitor average blood glucose control over the preceding two to three months. It is used in diabetes clinics, hospital laboratories and large population screening programs.
Overview
In cation-exchange HPLC, a hemolysate is injected onto a cation-exchange column, and a stepwise gradient of phosphate buffer with rising ionic strength elutes hemoglobin fractions in sequence: HbA1a, HbA1b, HbF, labile and stable A1c, HbA0, and variants such as HbS and HbC. A dual-wavelength detector at 415 and 690 nm records each peak, and software integrates the stable A1c area as a percentage of total hemoglobin. Results are aligned to IFCC and NGSP standardization and reported in mmol/mol and percent. Other platforms use boronate-affinity separation, immunoassay or enzymatic methods. HPLC gives peak-level visibility of variants and interfering fractions, and most analyzers complete a sample in about 1 to 2 minutes using a primary tube with automatic hemolysis.
How does it work?
Most clinical analyzers quantify an analyte by converting its concentration into a measurable signal. Photometric analyzers mix sample with reagent in a reaction cuvette, hold it at 37 °C, and measure absorbance at selected wavelengths through a grating or filter wheel; concentration follows the Beer–Lambert relation against a calibration curve. Ion-selective electrode modules measure the potential of Na+, K+ and Cl- across a selective membrane relative to a reference electrode. Turbidimetric and nephelometric modules detect light scattered by antigen-antibody complexes. Chromatographic analyzers separate hemoglobin fractions by cation-exchange HPLC. Key components include a sample and reagent probe with liquid-level detection, a precision syringe, a thermostatted reaction unit, a detection optic, and software that applies calibration, quality control rules and result flagging.
What are the key features?
- Cation-exchange HPLC with stable A1c quantification
- Dual-wavelength detection at 415 and 690 nm
- Variant hemoglobin detection through chromatogram review
- Primary tube sampling with automatic hemolysis and dilution
- Results traceable to IFCC and NGSP
- Autosampler rack capacity of 40 to 100 tubes
What are the technical specifications?
A typical hba1c glycohemoglobin analyzer configuration offers method of Cation-exchange HPLC, analysis time of ~1–2 min per sample, measuring range of HbA1c 3.0–20.0 % (9–195 mmol/mol), precision of CV ≤ 2 % (typical), sample volume of 5–20 µL whole blood and detection wavelength of 415 nm and 690 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The HbA1c Glycohemoglobin Analyzer is used in diabetes diagnosis and monitoring, hospital and reference laboratories, population health screening and hemoglobin variant detection. Across the wider Clinical Analyzers class, laboratories also deploy it for routine serum chemistry, electrolyte and blood gas testing and diabetes monitoring (HbA1c).
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05-A3, CLSI EP06, CLSI C24, IEC 61010-2-101 and IEC 61010-1. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install on a level bench away from direct sunlight, vibration and strong electromagnetic sources, with stable power, a dedicated earth and a supply of purified water that meets CLSI Type II quality where the analyzer requires it. Verify performance before clinical use through precision, linearity, carryover and method comparison studies in line with CLSI EP protocols. Run internal quality control every day and join an external quality assessment scheme. Schedule daily probe cleaning, weekly lamp and cuvette checks, and replacement of tubing, syringes and lamps per the maintenance plan. Treat all samples and waste as biohazardous and follow local regulations for disposal.
How do I select the right HbA1c Glycohemoglobin Analyzer?
Choose this variant when HbA1c is a high-volume test or when hemoglobin variants such as HbS, HbC, HbE or high HbF are prevalent in your population, since chromatography shows them directly. In the RFQ specify throughput, tube type, traceability claims, column life and data export. Point-of-care devices suit small clinics.
How does it compare with other Clinical Analyzers variants?
Start with the test menu and daily workload, because throughput and reagent format set the platform. Low volumes of routine chemistry suit a semi-automated photometer, while several hundred samples a day call for a benchtop random-access analyzer. Decide whether you need open reagent channels, which lower cost per test but require you to validate each assay, or closed reagent systems that simplify operation. Check sample volume needs for pediatric work, onboard reagent capacity, cuvette type and waste handling. For electrolytes, blood gas or HbA1c, choose a dedicated analyzer rather than stretching a general chemistry unit. Confirm LIS connectivity through HL7 or ASTM, barcode reading, and the availability of service engineers and spare parts in your region.
Full specifications
| Method | Cation-exchange HPLC |
|---|---|
| Analysis time | ~1–2 min per sample |
| Measuring range | HbA1c 3.0–20.0 % (9–195 mmol/mol) |
| Precision | CV ≤ 2 % (typical) |
| Sample volume | 5–20 µL whole blood |
| Detection wavelength | 415 nm and 690 nm |
| Sample capacity | 40–100 tubes |
| Standardization | IFCC and NGSP traceable |
| Column life | 1,500–2,000 injections (typical) |
| Throughput | 30–60 samples/h |
| Interface | USB, RS-232, HL7/ASTM |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Diabetes diagnosis and monitoring
- Hospital and reference laboratories
- Population health screening
- Hemoglobin variant detection
Key features
- Cation-exchange HPLC with stable A1c quantification
- Dual-wavelength detection at 415 and 690 nm
- Variant hemoglobin detection through chromatogram review
- Primary tube sampling with automatic hemolysis and dilution
- Results traceable to IFCC and NGSP
- Autosampler rack capacity of 40 to 100 tubes
Frequently asked questions about HbA1c Glycohemoglobin Analyzer
It measures the percentage of hemoglobin that has glucose bound to the beta chain, which reflects average blood glucose over the preceding two to three months. Results are reported in percent (NGSP) and mmol/mol (IFCC) and used for diabetes diagnosis and treatment monitoring.
HPLC separates hemoglobin fractions, so variants such as HbS, HbC and elevated HbF appear as distinct peaks and can be identified or flagged. Immunoassays are simpler and can run on chemistry analyzers but may not reveal variants, which can bias results in some patients.
Conditions that change red cell lifespan, such as hemolytic anemia, recent transfusion, iron deficiency and chronic kidney disease, can distort HbA1c. Some hemoglobin variants interfere depending on the method. The laboratory should note these limitations and consider alternative markers such as fructosamine where needed.
A clinical analyzer measures concentrations of substances such as glucose, enzymes, electrolytes, lipids and proteins in patient samples. Results support diagnosis, treatment decisions and monitoring in hospitals, clinics and reference laboratories. Different platforms cover chemistry, electrolytes, blood gases, specific proteins and HbA1c.
An open system accepts reagents from any supplier once channel parameters are programmed and validated, which gives flexibility and lower cost per test. A closed system uses reagents supplied for that platform with pre-set parameters and barcodes, which simplifies operation but limits supplier choice.
Calibration frequency depends on the assay and reagent lot. Many photometric tests are recalibrated at each new reagent lot, after major maintenance, or when quality control shifts beyond limits. Electrolyte electrodes are typically calibrated automatically every few hours. Follow the reagent instructions for use and your laboratory procedure.
Related models