Key specifications
| Throughput | 400–1,200 tubes/h |
|---|---|
| Tube diameter | 12–16 mm |
| Tube height | 75–100 mm |
| Cap types | Screw caps, push-in stoppers, vacuum tube stoppers |
| Decapping torque | Adjustable 0.3–2.0 N·m |
| Rack capacity | 5–10 racks of 5–10 tubes |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI GP44, CLSI AUTO01
What is the Automated Tube Decapper and Recapper?
An automated tube decapper and recapper removes stoppers from primary sample tubes and reseals them after testing. It lowers aerosol exposure and repetitive strain for staff, and is used by laboratories that open several hundred tubes each day before loading analyzers.
What is the Automated Tube Decapper and Recapper?
An automated tube decapper and recapper removes stoppers from primary sample tubes and reseals them after testing. It lowers aerosol exposure and repetitive strain for staff, and is used by laboratories that open several hundred tubes each day before loading analyzers.
Overview
A decapper grips the tube body and removes the cap by controlled rotation for screw caps or by vertical pull for push-in stoppers. Torque and force sensors detect resistance, cap type and stuck caps, and the machine may stop to avoid tube breakage. Removed caps fall into a biohazard bin or are held for re-use, and some models use a HEPA-filtered enclosure to contain aerosols. The recapper applies either the original cap or a new foil seal or pierceable cap after analysis. Throughput is commonly 400 to 1,200 tubes per hour. Standalone benchtop units process racks manually loaded by staff, while inline modules mount on a track. Adjustable grippers handle 12 to 16 mm diameter tubes and heights from 75 to 100 mm, including vacuum blood tubes and conical centrifuge tubes.
How does it work?
Pre-analytical automation combines barcode identification, robotic handling and liquid transfer. A tube enters on an input lane where a camera or laser scanner reads the barcode and a vision system identifies tube type, cap color and height. A gripper lifts the tube, and a decapper removes the stopper by torque-controlled rotation or pull, detecting cap type to avoid breakage. Sorting systems route tubes by test request through conveyors, diverters or robotic arms into racks for each analyzer. Aliquoters use disposable tips on a pipetting channel with capacitive liquid-level detection and clot detection to transfer serum or plasma to labeled secondary tubes. Recappers apply a new cap or pierceable seal to limit evaporation and aerosol. Everything is coordinated by middleware that exchanges orders and results with the laboratory information system.
What are the key features?
- Torque-controlled removal of screw caps and pull removal of stoppers
- Force sensing to detect stuck caps and prevent tube breakage
- Optional HEPA-filtered enclosure to contain aerosols
- Recapping with original cap, foil seal or pierceable cap
- Adjustable grippers for 12 to 16 mm diameter tubes
- Benchtop rack mode or inline mode on a track
What are the technical specifications?
A typical automated tube decapper and recapper configuration offers throughput of 400–1,200 tubes/h, tube diameter of 12–16 mm, tube height of 75–100 mm, cap types of Screw caps, push-in stoppers, vacuum tube stoppers, decapping torque of Adjustable 0.3–2.0 N·m and rack capacity of 5–10 racks of 5–10 tubes. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Tube Decapper and Recapper is used in pre-analytical preparation before chemistry analysis, serology and immunoassay laboratories, blood bank and transfusion testing and sample archiving after testing. Across the wider Sample Processing class, laboratories also deploy it for hospital central laboratory pre-analytics, reference laboratory high-volume receiving and blood bank sample preparation.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI GP44, CLSI AUTO01, CLSI AUTO03, ISO 15190 and IEC 61010-2-101. Certification candidates for this model are CE and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sample handling must protect staff and sample integrity. Place equipment where racks and conveyors connect to analyzers, and supply stable power and network. Validate barcode quality against the label specifications and test each tube type from your collection supplier. Verify aliquot volume accuracy, carryover, and absence of cross-contamination with dye or analyte studies. Review centrifugation and pre-analytical stability limits for each analyte so automated waiting times do not compromise results. Decontaminate grippers and decks per the manual, and dispose of tips and caps as biohazardous waste. Keep spare grippers and sensors on site, and document validation under ISO 15189.
How do I select the right Automated Tube Decapper and Recapper?
Choose this variant when staff open more than about 300 tubes per shift or when aerosol or repetitive strain is a concern. In the RFQ specify the tube types and cap styles, hourly throughput, HEPA requirement, recapping method and whether the unit must be standalone or integrated with an analyzer track.
How does it compare with other Sample Processing variants?
Begin with daily tube volume and the tube types in use, because capacity and gripper compatibility differ. A laboratory processing under 300 tubes a day may only need a labeler or a standalone decapper, while over 1,000 tubes a day justifies a sorter with aliquoting. Check the range of tube diameters, 12 to 16 mm, and heights, 75 to 100 mm, that the system accepts, and whether it handles pediatric micro-tubes and gel tubes. Evaluate cap removal reliability, aerosol containment and whether it handles screw and push caps. Confirm middleware and LIS connectivity, footprint, consumable cost for tips and caps, and the service response commitment, since downtime stops the whole pre-analytical flow.
Full specifications
| Throughput | 400–1,200 tubes/h |
|---|---|
| Tube diameter | 12–16 mm |
| Tube height | 75–100 mm |
| Cap types | Screw caps, push-in stoppers, vacuum tube stoppers |
| Decapping torque | Adjustable 0.3–2.0 N·m |
| Rack capacity | 5–10 racks of 5–10 tubes |
| Aerosol control | Optional HEPA H13 filtration |
| Recapping options | Foil seal, pierceable cap, original cap |
| Cap waste | Sealed biohazard bin, 5–10 L |
| Interface | USB, Ethernet |
| Power supply | 220 V AC, 50/60 Hz, 300 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pre-analytical preparation before chemistry analysis
- Serology and immunoassay laboratories
- Blood bank and transfusion testing
- Sample archiving after testing
Key features
- Torque-controlled removal of screw caps and pull removal of stoppers
- Force sensing to detect stuck caps and prevent tube breakage
- Optional HEPA-filtered enclosure to contain aerosols
- Recapping with original cap, foil seal or pierceable cap
- Adjustable grippers for 12 to 16 mm diameter tubes
- Benchtop rack mode or inline mode on a track
Frequently asked questions about Automated Tube Decapper and Recapper
Many can, using torque-controlled rotation for screw caps and vertical pull for stoppers, with settings selected by tube type. Confirm the specific cap and stopper styles from your tube supplier, because design differences can affect grip and breakage rates.
A new foil seal or pierceable cap limits evaporation and aerosol formation during storage, which helps with stability of analytes such as ammonia and ionized calcium. It also keeps samples for reflex testing, although long-term storage should still be at controlled temperature.
It is not mandatory but is recommended where infectious samples are handled or where local biosafety policy requires aerosol control. An H13 HEPA filter captures at least 99.95 percent of particles at 0.3 µm, and filters need periodic replacement and leak testing.
It covers all steps from specimen collection to analysis, including identification, transport, centrifugation, decapping, aliquoting and sorting. Most laboratory errors arise in this phase, so automation of labeling, decapping and aliquoting reduces mislabeling, exposure risk and delay before samples reach the analyzers.
Aliquoting lets one patient specimen serve several analyzers or tests at once and allows a stored portion for retesting. It also separates serum from cells after centrifugation, limits repeated freeze-thaw, and avoids sending primary tubes through multiple instruments.
Most systems accept a defined range of tube diameters and heights, often 12 to 16 mm diameter and 75 to 100 mm height, with adapters for pediatric tubes. Cap designs vary, so confirm compatibility with each tube manufacturer's products and test them before commissioning.