Dual-Fluorescence Cell Counter

双荧光细胞计数仪

  • SKU CEC-0002
  • Cell Counters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Sample volume10–20 µL per count
Counting timeunder 1 min
Concentration rangeapprox. 1 x 10⁴–1 x 10⁷ cells/mL
Viability rangecapable below 50% viable cells
Excitationapprox. 470 nm (blue) and 530 nm (green)
Emission channelsapprox. 525 nm green and 600 nm red
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20387, ISO 15189, IEC 61010-1

What is the Dual-Fluorescence Cell Counter?

A dual-fluorescence cell counter stains nuclei with acridine orange and propidium iodide and measures both channels, reporting concentration and viability even in samples containing red blood cells, platelets or debris. It is preferred when accuracy matters more than cost per count.

What is the Dual-Fluorescence Cell Counter?

A dual-fluorescence cell counter stains nuclei with acridine orange and propidium iodide and measures both channels, reporting concentration and viability even in samples containing red blood cells, platelets or debris. It is preferred when accuracy matters more than cost per count.

Overview

Acridine orange labels all nucleated cells green, and propidium iodide labels only cells with compromised membranes red. Because both dyes target nucleic acid, only nucleated objects are counted and non-nucleated debris, red blood cells and platelets are ignored. This makes the method robust for samples such as bone marrow, peripheral blood, tissue digests and low-viability cryopreserved vials, where trypan blue counting is unreliable. Typical sample volume is 10–20 µL and counting takes under a minute. Concentration linearity spans about 10⁴ to 10⁷ cells/mL, and viability is reported along with counts of green-only and red-only objects. Sensitivity is high enough to quantify viabilities below 50%, where dye exclusion methods lose accuracy, and results can be exported for batch records.

How does it work?

Counting methods differ in how they distinguish a cell from debris and from a dead cell. Trypan blue exclusion relies on the intact membrane of viable cells, which excludes the dye, so live cells appear bright and dead cells blue in transmitted light; automated counters image a fixed volume in a counting chamber and classify objects by size, shape and brightness. Fluorescence methods use acridine orange and propidium iodide, which stain all nuclei and membrane-damaged nuclei respectively, so concentration and viability are derived from two channels and are less affected by red blood cells, platelets and debris. Electrical impedance counters draw cells through a small aperture and count voltage pulses, where pulse height reflects cell volume. Flow cytometry counters add a known number of reference beads and calculate absolute counts from the ratio of cell to bead events, which also provides marker information. All methods require a well-mixed, appropriately diluted sample to be accurate.

What are the key features?

  • Acridine orange and propidium iodide dual-channel staining
  • Counts nucleated cells only, ignoring red cells and debris
  • Reliable viability measurement below 50% viable cells
  • Counting completed in under one minute per sample
  • Separate green-only, red-only and total object counts
  • Result export suitable for batch and quality records

What are the technical specifications?

A typical dual-fluorescence cell counter configuration offers sample volume of 10–20 µL per count, counting time of under 1 min, concentration range of approx. 1 x 10⁴–1 x 10⁷ cells/mL, viability range of capable below 50% viable cells, excitation of approx. 470 nm (blue) and 530 nm (green) and emission channels of approx. 525 nm green and 600 nm red. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dual-Fluorescence Cell Counter is used in blood and bone marrow sample counting, cryopreserved cell viability assessment, tissue digest and organoid cell counts and cell therapy product quality control. Across the wider Cell Counters class, laboratories also deploy it for seeding density determination before experiments, culture growth and viability monitoring and cell therapy product release counts.

Which standards and certifications apply?

Relevant standards and methods include ISO 20387, ISO 15189, IEC 61010-1, IEC 60825-1, USP <1046> and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Accuracy depends more on sample handling than on the instrument. Cells settle quickly, so mix by gentle inversion or low-speed pipetting immediately before sampling, and avoid vigorous vortexing that damages membranes. Dilute into the method's linear range, since concentrated samples saturate the sensor and very dilute samples lose precision. Consumables such as counting slides or chambers should be used once and disposed of as biohazard waste. Clean the optics and sample path regularly, and avoid samples containing strong dyes or fluorescent compounds that interfere with fluorescence channels. Validate each new cell type or matrix against a reference method such as a haemocytometer or a validated flow count, and document the dilution and settings used, because viability definitions differ between laboratories.

How do I select the right Dual-Fluorescence Cell Counter?

Select a dual-fluorescence counter when samples contain non-nucleated cells or debris, when viability is low, or when results must be defensible in a quality record. Specify concentration and viability ranges, dye kit format, output format and the reference method used for verification.

How does it compare with other Cell Counters variants?

Choose by sample type and required accuracy. For routine culture of established cell lines, an image-based counter with trypan blue is adequate and inexpensive. When samples contain debris, red cells, platelets or clumps, or when viability is low and must be measured precisely, choose a fluorescence counter with acridine orange and propidium iodide, which reports concentration and viability from nuclear staining. Impedance counters are useful for continuous monitoring of cell size distribution and for samples where optical clarity varies. Flow cytometry counters are the right choice when counts must be combined with surface marker measurement or when absolute counts are required for clinical reporting. Check the linear range, sample volume, time per count, consumable cost, cleaning requirements and whether the instrument reports aggregate or clump correction.

Full specifications

Full specifications
Sample volume10–20 µL per count
Counting timeunder 1 min
Concentration rangeapprox. 1 x 10⁴–1 x 10⁷ cells/mL
Viability rangecapable below 50% viable cells
Excitationapprox. 470 nm (blue) and 530 nm (green)
Emission channelsapprox. 525 nm green and 600 nm red
DetectorCooled CMOS or CCD camera
Cell size rangeapprox. 5–60 µm
Data outputCSV and PDF report export
Dimensions (W x D x H)approx. 250 x 350 x 300 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Blood and bone marrow sample counting
  • Cryopreserved cell viability assessment
  • Tissue digest and organoid cell counts
  • Cell therapy product quality control

Key features

  • Acridine orange and propidium iodide dual-channel staining
  • Counts nucleated cells only, ignoring red cells and debris
  • Reliable viability measurement below 50% viable cells
  • Counting completed in under one minute per sample
  • Separate green-only, red-only and total object counts
  • Result export suitable for batch and quality records

Frequently asked questions about Dual-Fluorescence Cell Counter

Nucleic acid dyes count only objects that contain a nucleus, so platelets, red blood cells and protein debris are excluded. Cells with damaged membranes are labelled red, which makes the viability call objective rather than dependent on optical contrast.

Related models

All Cell Counters
Flow Cytometry Cell Counter — product photo

Flow Cytometry Cell Counter

流式细胞计数仪

  • CE (to be confirmed)
  • +3
Request a quote
Imaging Flow Cytometer — product photo

Imaging Flow Cytometer

成像流式细胞仪

  • CE (to be confirmed)
  • +3
Request a quote

Request a quotation for the Dual-Fluorescence Cell Counter

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote