Flow Cytometry Cell Counter
流式细胞计数仪
- SKU CEC-0004
- Cell Counters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- IVD marking (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Reference beads | Known concentration suspension added in fixed volume |
|---|---|
| Fluorescence channels | 4–12 (instrument dependent) |
| Counting accuracy | within ±5–10% of reference method |
| Concentration range | approx. 1 x 10³–1 x 10⁷ cells/mL |
| Sample volume | 50–500 µL per acquisition |
| Acquisition rate | up to 10,000 events per second |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20387, ISO 15189, IEC 61010-1
What is the Flow Cytometry Cell Counter?
A flow cytometry cell counter mixes the sample with a known number of reference beads and calculates absolute counts from the ratio of cell to bead events, combining concentration measurement with marker and viability information in one acquisition.
What is the Flow Cytometry Cell Counter?
A flow cytometry cell counter mixes the sample with a known number of reference beads and calculates absolute counts from the ratio of cell to bead events, combining concentration measurement with marker and viability information in one acquisition.
Overview
Absolute counting by flow cytometry uses a lyophilised or liquid bead suspension of known concentration added in a fixed volume to the sample. During acquisition, the instrument records events in a counting gate for beads and separate gates for cells and cell subsets, and software calculates concentration from the bead count and the dilution factor. Because gating can exclude debris, red cells and dead cells, viability-adjusted subset counts can be reported, which is valuable for immunophenotyping and for clinical lymphocyte subset enumeration. Typical accuracy is within 5–10% of a reference method when bead concentration and pipetting are controlled. The approach requires careful pipetting, since a volume error propagates directly into the result, and it needs validated panels and compensation settings.
How does it work?
Counting methods differ in how they distinguish a cell from debris and from a dead cell. Trypan blue exclusion relies on the intact membrane of viable cells, which excludes the dye, so live cells appear bright and dead cells blue in transmitted light; automated counters image a fixed volume in a counting chamber and classify objects by size, shape and brightness. Fluorescence methods use acridine orange and propidium iodide, which stain all nuclei and membrane-damaged nuclei respectively, so concentration and viability are derived from two channels and are less affected by red blood cells, platelets and debris. Electrical impedance counters draw cells through a small aperture and count voltage pulses, where pulse height reflects cell volume. Flow cytometry counters add a known number of reference beads and calculate absolute counts from the ratio of cell to bead events, which also provides marker information. All methods require a well-mixed, appropriately diluted sample to be accurate.
What are the key features?
- Reference bead method for absolute cell concentration
- Gating excludes debris, red cells and dead cells
- Combined concentration, viability and marker information
- Subset-specific counts with viability adjustment
- Validated panels and compensation for clinical use
- Integrated reporting with bead count and dilution factor
What are the technical specifications?
A typical flow cytometry cell counter configuration offers reference beads of Known concentration suspension added in fixed volume, fluorescence channels of 4–12 (instrument dependent), counting accuracy of within ±5–10% of reference method, concentration range of approx. 1 x 10³–1 x 10⁷ cells/mL, sample volume of 50–500 µL per acquisition and acquisition rate of up to 10,000 events per second. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Flow Cytometry Cell Counter is used in lymphocyte subset enumeration, immunophenotyping with absolute counts, cell therapy product characterisation and viability-adjusted cell dosing calculations. Across the wider Cell Counters class, laboratories also deploy it for seeding density determination before experiments, culture growth and viability monitoring and cell therapy product release counts.
Which standards and certifications apply?
Relevant standards and methods include ISO 20387, ISO 15189, IEC 61010-1, IEC 60825-1, USP <1046> and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IVD marking; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Accuracy depends more on sample handling than on the instrument. Cells settle quickly, so mix by gentle inversion or low-speed pipetting immediately before sampling, and avoid vigorous vortexing that damages membranes. Dilute into the method's linear range, since concentrated samples saturate the sensor and very dilute samples lose precision. Consumables such as counting slides or chambers should be used once and disposed of as biohazard waste. Clean the optics and sample path regularly, and avoid samples containing strong dyes or fluorescent compounds that interfere with fluorescence channels. Validate each new cell type or matrix against a reference method such as a haemocytometer or a validated flow count, and document the dilution and settings used, because viability definitions differ between laboratories.
How do I select the right Flow Cytometry Cell Counter?
Select flow cytometry counting when concentration must be combined with marker expression or when viability-adjusted subset counts are needed for reporting. Specify laser and detector configuration, supported bead kits, panel validation support and whether the instrument is registered for clinical use.
How does it compare with other Cell Counters variants?
Choose by sample type and required accuracy. For routine culture of established cell lines, an image-based counter with trypan blue is adequate and inexpensive. When samples contain debris, red cells, platelets or clumps, or when viability is low and must be measured precisely, choose a fluorescence counter with acridine orange and propidium iodide, which reports concentration and viability from nuclear staining. Impedance counters are useful for continuous monitoring of cell size distribution and for samples where optical clarity varies. Flow cytometry counters are the right choice when counts must be combined with surface marker measurement or when absolute counts are required for clinical reporting. Check the linear range, sample volume, time per count, consumable cost, cleaning requirements and whether the instrument reports aggregate or clump correction.
Full specifications
| Reference beads | Known concentration suspension added in fixed volume |
|---|---|
| Fluorescence channels | 4–12 (instrument dependent) |
| Counting accuracy | within ±5–10% of reference method |
| Concentration range | approx. 1 x 10³–1 x 10⁷ cells/mL |
| Sample volume | 50–500 µL per acquisition |
| Acquisition rate | up to 10,000 events per second |
| Lasers | 488 nm standard, optional 405 or 640 nm |
| Carry-over | below 1% with validated wash procedure |
| Data output | FCS files with absolute count reports |
| Dimensions (W x D x H) | approx. 500 x 600 x 600 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Lymphocyte subset enumeration
- Immunophenotyping with absolute counts
- Cell therapy product characterisation
- Viability-adjusted cell dosing calculations
Key features
- Reference bead method for absolute cell concentration
- Gating excludes debris, red cells and dead cells
- Combined concentration, viability and marker information
- Subset-specific counts with viability adjustment
- Validated panels and compensation for clinical use
- Integrated reporting with bead count and dilution factor
Frequently asked questions about Flow Cytometry Cell Counter
A fixed volume of bead suspension of known concentration is added to the sample. The instrument counts bead and cell events separately, and concentration is calculated as cell events divided by bead events, multiplied by the bead concentration and the dilution factor.
The result depends on the exact sample and bead volumes, so a pipetting error of a few percent shifts the count by the same proportion. Using calibrated pipettes and adding beads to a measured sample volume are essential for clinical accuracy.
Yes. A viability dye such as 7-AAD or propidium iodide allows dead cells to be gated out, so the reported count reflects viable cells only. Reporting both total and viable counts is common practice in cell therapy and immunology.
Most benchtop counters use 10–20 µL per count, and some fluorescence systems accept as little as 10 µL when viability is measured from nuclear staining. Samples are usually diluted with dye or buffer before counting.
Trypan blue measures membrane integrity, whereas fluorescence nuclear dyes also detect early apoptosis and can include cells that have lost nuclear structure. Instruments also differ in how they classify small or clumped objects, so methods should not be mixed within a study.
Gently pipette the suspension with a wide-bore tip or filter through a 40 µm mesh to break clumps before counting. Some instruments apply a clump correction factor, which should be verified against a reference count for each cell type.