Analytical Balance with Automatic Draft-Shield Doors
自动防风门分析天平
- SKU ANB-0004
- Analytical Balances
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Readability | 0.1 mg or 0.01 mg |
|---|---|
| Capacity | 52–320 g |
| Repeatability (SD) | 0.015–0.1 mg |
| Door actuation | Sensor or key, motorized |
| Door opening programs | 3–4 preset widths |
| Stabilization time | ≈ 2–5 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <41>, USP <1251>, OIML R 76-1
What is the Analytical Balance with Automatic Draft-Shield Doors?
This analytical balance opens and closes its draft-shield doors by motor, triggered by a sensor or key, and keeps the chamber closed during weighing. It reduces air disturbance, static and operator influence, and is useful for hygroscopic or powder samples and repetitive weighing.
What is the Analytical Balance with Automatic Draft-Shield Doors?
This analytical balance opens and closes its draft-shield doors by motor, triggered by a sensor or key, and keeps the chamber closed during weighing. It reduces air disturbance, static and operator influence, and is useful for hygroscopic or powder samples and repetitive weighing.
Overview
Motorized doors add convenience and measurement stability to a standard 0.1 mg or 0.01 mg balance. Hand-free sensors or function keys open the side or top door, so the operator can keep both hands on vessels and spatulas. Door opening width is programmable, limiting the exchange of air when only a small gap is needed. Doors close automatically once the pan is loaded, which shortens stabilization time and reduces evaporation errors in volatile samples. Many models combine the drive with an ionizing bar to neutralize static. Capacity is typically 120 to 320 g at 0.1 mg readability, or 52 to 120 g at 0.01 mg. The extra mechanism calls for occasional cleaning of door tracks and adds slightly to cost.
How does it work?
Most analytical balances use electromagnetic force restoration. A weighing pan is attached to a lever system or monolithic cell, and a coil in a permanent magnetic field generates the force that returns the pan to its reference position. The coil current needed to do this is proportional to the load and is converted by an analog-to-digital converter into a mass reading. Optical or inductive sensors detect pan position. A draft shield isolates the pan from air currents, and temperature sensors compensate drift. Internal calibration uses a built-in reference mass driven by a motor, while external calibration uses a traceable weight placed by the operator. Leveling feet and a level indicator ensure the pan is vertical. Electronics apply filters to stabilize readings against vibration.
What are the key features?
- Motorized side and top doors opened by sensor or key
- Programmable door opening width to limit air exchange
- Doors close automatically when weighing starts
- Optional integrated ionizer to reduce static charge
- Hands-free operation for repetitive and powder weighing
What are the technical specifications?
A typical analytical balance with automatic draft-shield doors configuration offers readability of 0.1 mg or 0.01 mg, capacity of 52–320 g, repeatability (SD) of 0.015–0.1 mg, door actuation of Sensor or key, motorized, door opening programs of 3–4 preset widths and stabilization time of ≈ 2–5 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Analytical Balance with Automatic Draft-Shield Doors is used in repetitive powder weighing, hygroscopic sample weighing, high-throughput sample preparation and weighing with gloves or protective equipment. Across the wider Analytical Balances class, laboratories also deploy it for pharmaceutical QC weighing, standard solution preparation and gravimetric analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <41>, USP <1251>, OIML R 76-1, Ph. Eur. 2.1.7, ASTM E898, GB/T 26497 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the balance on a rigid, vibration-free bench away from doors, air conditioning vents, direct sunlight and heat sources. Allow warm-up of at least 30 minutes to a few hours before use, as specified by the manufacturer. Level the balance and calibrate after every move. Routine checks with certified weights, plus periodic calibration by an accredited service, support compliance with pharmacopoeial requirements. Keep the pan and chamber clean, and avoid placing samples directly on the pan. Control humidity roughly between 40 and 60 percent to limit static and drift. Use antistatic accessories for powders. Record routine tests, eccentricity and repeatability to support quality audits.
How do I select the right Analytical Balance with Automatic Draft-Shield Doors?
Select automatic doors when weighing is repetitive, samples are static-prone or hygroscopic, or operators wear gloves and need both hands free. Manual shields are cheaper and simpler. In the RFQ, specify door configuration, sensor type, ionizer, readability and capacity.
How does it compare with other Analytical Balances variants?
Decide readability first. A 0.1 mg balance serves most routine weighing, while 0.01 mg semi-micro models are needed for small samples or minimum weight limits of a few milligrams. Then check capacity, since higher capacity usually reduces repeatability. Consider how calibration will be handled: internal calibration reduces operator effort and drift in variable conditions, while external calibration is cheaper. For regulated laboratories, verify data-integrity software, audit trail and printouts. Automatic draft-shield doors reduce operator influence and static. Also consider the installation site, because vibration, drafts and temperature change affect performance more than the nominal specification. Finally, check the minimum weight at the required tolerance, using the balance's own repeatability data rather than readability alone.
Full specifications
| Readability | 0.1 mg or 0.01 mg |
|---|---|
| Capacity | 52–320 g |
| Repeatability (SD) | 0.015–0.1 mg |
| Door actuation | Sensor or key, motorized |
| Door opening programs | 3–4 preset widths |
| Stabilization time | ≈ 2–5 s |
| Calibration | Internal |
| Ionizer | Optional integrated |
| Interfaces | RS-232, USB, Ethernet optional |
| Power supply | 100–240 V AC adapter |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Repetitive powder weighing
- Hygroscopic sample weighing
- High-throughput sample preparation
- Weighing with gloves or protective equipment
Key features
- Motorized side and top doors opened by sensor or key
- Programmable door opening width to limit air exchange
- Doors close automatically when weighing starts
- Optional integrated ionizer to reduce static charge
- Hands-free operation for repetitive and powder weighing
Frequently asked questions about Analytical Balance with Automatic Draft-Shield Doors
They improve consistency rather than intrinsic accuracy. By closing the chamber immediately and opening only as far as needed, they limit air currents, evaporation and operator influence, which shortens settling time and reduces reading scatter for sensitive samples.
Yes. Sensor-based operation works without touching, and function keys are usually large enough for gloved hands. This also lowers contamination risk when weighing potent or hazardous powders.
Wipe the glass and clean door tracks regularly to prevent powder build-up that can jam the mechanism. Check that door sensors are not obstructed, and have the drive inspected during annual service. Do not force doors manually while the power is on.
An analytical balance reads to 0.1 mg or finer, has a draft shield and typically weighs up to 320 g. A precision balance reads to 1 mg up to 0.01 g, is open or has a simple shield, and handles larger capacities. Analytical models suit sample preparation and assays.
Perform a quick check with a certified weight each day of use, and calibrate after moving or leveling the balance. A full calibration and uncertainty assessment by an accredited provider is typically done annually or as set by the laboratory's risk assessment and quality system.
Minimum weight is the smallest sample mass that can be weighed at a stated relative tolerance, for example 0.1 percent. It depends on the balance's repeatability and is often about 1000 times the standard deviation. USP <41> bases it on measured repeatability.