GLP-Compliant Analytical Balance with Data-Integrity Software
符合 GLP 要求的带数据完整性软件分析天平
- SKU ANB-0005
- Analytical Balances
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- OIML R 76 type approval (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Readability | 0.1 mg or 0.01 mg |
|---|---|
| Capacity | 52–320 g |
| Repeatability (SD) | 0.015–0.1 mg |
| Calibration | Internal motorized |
| User management | Multi-level, password protected |
| Audit trail | Time-stamped, non-editable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <41>, USP <1251>, OIML R 76-1
What is the GLP-Compliant Analytical Balance with Data-Integrity Software?
This analytical balance adds user login, audit trail, electronic records and validated data transfer to a 0.1 mg or 0.01 mg weighing platform. It supports ALCOA+ data-integrity practice in pharmaceutical and other regulated laboratories.
What is the GLP-Compliant Analytical Balance with Data-Integrity Software?
This analytical balance adds user login, audit trail, electronic records and validated data transfer to a 0.1 mg or 0.01 mg weighing platform. It supports ALCOA+ data-integrity practice in pharmaceutical and other regulated laboratories.
Overview
Regulated laboratories need weighing data that are attributable, legible, contemporaneous, original and accurate. This balance provides password-protected user roles, an unalterable audit trail of settings changes and calibrations, and time-stamped electronic records. Weighing results, test weight checks and adjustment data can be exported to LIMS, ELN or a validated PC application through USB or Ethernet with checksum protection. Software can support 21 CFR Part 11 and EU Annex 11 controls when the laboratory validates and configures it accordingly. The mechanical platform is typically a 0.1 mg or 0.01 mg internal-calibration balance, with routine test wizards for repeatability, eccentricity and sensitivity. Printouts carry balance ID, user, date and calibration status. Validation documentation and IQ/OQ support are usually provided as options.
How does it work?
Most analytical balances use electromagnetic force restoration. A weighing pan is attached to a lever system or monolithic cell, and a coil in a permanent magnetic field generates the force that returns the pan to its reference position. The coil current needed to do this is proportional to the load and is converted by an analog-to-digital converter into a mass reading. Optical or inductive sensors detect pan position. A draft shield isolates the pan from air currents, and temperature sensors compensate drift. Internal calibration uses a built-in reference mass driven by a motor, while external calibration uses a traceable weight placed by the operator. Leveling feet and a level indicator ensure the pan is vertical. Electronics apply filters to stabilize readings against vibration.
What are the key features?
- Password-protected user roles with access levels
- Audit trail of calibrations, setting changes and results
- Routine test wizards for repeatability, eccentricity and sensitivity
- Secure export to LIMS, ELN or PC software over USB or Ethernet
- Printouts with balance ID, user, date and calibration status
What are the technical specifications?
A typical glp-compliant analytical balance with data-integrity software configuration offers readability of 0.1 mg or 0.01 mg, capacity of 52–320 g, repeatability (SD) of 0.015–0.1 mg, calibration of Internal motorized, user management of Multi-level, password protected and audit trail of Time-stamped, non-editable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The GLP-Compliant Analytical Balance with Data-Integrity Software is used in pharmaceutical QC weighing, GMP release testing, stability study sample preparation and GLP toxicology and research laboratories. Across the wider Analytical Balances class, laboratories also deploy it for pharmaceutical QC weighing, standard solution preparation and gravimetric analysis.
Which standards and certifications apply?
Relevant standards and methods include USP <41>, USP <1251>, OIML R 76-1, Ph. Eur. 2.1.7, ASTM E898, GB/T 26497 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and OIML R 76 type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the balance on a rigid, vibration-free bench away from doors, air conditioning vents, direct sunlight and heat sources. Allow warm-up of at least 30 minutes to a few hours before use, as specified by the manufacturer. Level the balance and calibrate after every move. Routine checks with certified weights, plus periodic calibration by an accredited service, support compliance with pharmacopoeial requirements. Keep the pan and chamber clean, and avoid placing samples directly on the pan. Control humidity roughly between 40 and 60 percent to limit static and drift. Use antistatic accessories for powders. Record routine tests, eccentricity and repeatability to support quality audits.
How do I select the right GLP-Compliant Analytical Balance with Data-Integrity Software?
Select this variant when the laboratory operates under GMP, GLP or ISO 17025 and needs electronic records, role control and audit trail. Non-regulated laboratories may not need the added cost. In the RFQ, specify readability, software compliance documentation, validation support, LIMS interface and user management needs.
How does it compare with other Analytical Balances variants?
Decide readability first. A 0.1 mg balance serves most routine weighing, while 0.01 mg semi-micro models are needed for small samples or minimum weight limits of a few milligrams. Then check capacity, since higher capacity usually reduces repeatability. Consider how calibration will be handled: internal calibration reduces operator effort and drift in variable conditions, while external calibration is cheaper. For regulated laboratories, verify data-integrity software, audit trail and printouts. Automatic draft-shield doors reduce operator influence and static. Also consider the installation site, because vibration, drafts and temperature change affect performance more than the nominal specification. Finally, check the minimum weight at the required tolerance, using the balance's own repeatability data rather than readability alone.
Full specifications
| Readability | 0.1 mg or 0.01 mg |
|---|---|
| Capacity | 52–320 g |
| Repeatability (SD) | 0.015–0.1 mg |
| Calibration | Internal motorized |
| User management | Multi-level, password protected |
| Audit trail | Time-stamped, non-editable |
| Data storage | ≥ 10,000 records |
| Display | Color touchscreen, 4–7 in |
| Interfaces | USB, Ethernet, RS-232 |
| Stabilization time | ≈ 2–5 s |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Pharmaceutical QC weighing
- GMP release testing
- Stability study sample preparation
- GLP toxicology and research laboratories
Key features
- Password-protected user roles with access levels
- Audit trail of calibrations, setting changes and results
- Routine test wizards for repeatability, eccentricity and sensitivity
- Secure export to LIMS, ELN or PC software over USB or Ethernet
- Printouts with balance ID, user, date and calibration status
Frequently asked questions about GLP-Compliant Analytical Balance with Data-Integrity Software
No. The balance software provides technical controls such as logins, audit trails and electronic signatures, but compliance also depends on laboratory procedures, configuration, validation and training. The laboratory remains responsible for demonstrating compliance.
ALCOA+ describes data as attributable, legible, contemporaneous, original, accurate, plus complete, consistent, enduring and available. A balance supports it through user login, time-stamped records, direct electronic transfer without transcription and preservation of original weighing data.
Yes, most models export data through USB, Ethernet or RS-232 using defined data strings or a vendor driver. Integration requires configuring the LIMS interface and confirming that transferred values match displayed values as part of the laboratory's validation.
An analytical balance reads to 0.1 mg or finer, has a draft shield and typically weighs up to 320 g. A precision balance reads to 1 mg up to 0.01 g, is open or has a simple shield, and handles larger capacities. Analytical models suit sample preparation and assays.
Perform a quick check with a certified weight each day of use, and calibrate after moving or leveling the balance. A full calibration and uncertainty assessment by an accredited provider is typically done annually or as set by the laboratory's risk assessment and quality system.
Minimum weight is the smallest sample mass that can be weighed at a stated relative tolerance, for example 0.1 percent. It depends on the balance's repeatability and is often about 1000 times the standard deviation. USP <41> bases it on measured repeatability.