Semi-Micro Analytical Balance

半微量分析天平

  • SKU ANB-0003
  • Analytical Balances
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • OIML R 76 type approval (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Readability0.01 mg
Capacity52–120 g
Repeatability (SD)≤ 0.015–0.03 mg
Linearity±0.05–0.1 mg
Minimum weight (0.1% tolerance)≈ 20–30 mg
Stabilization time≈ 4–8 s
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <41>, USP <1251>, OIML R 76-1

What is the Semi-Micro Analytical Balance?

A semi-micro analytical balance reads to 0.01 mg with capacities of about 52 to 120 g, allowing accurate weighing of small samples with low minimum weight. It is used for reference standards, impurity work and content uniformity preparations.

What is the Semi-Micro Analytical Balance?

A semi-micro analytical balance reads to 0.01 mg with capacities of about 52 to 120 g, allowing accurate weighing of small samples with low minimum weight. It is used for reference standards, impurity work and content uniformity preparations.

Overview

A semi-micro balance offers ten times finer readability than a standard analytical unit. It uses a higher-resolution electromagnetic cell and a more thoroughly enclosed draft shield to keep air movement from disturbing readings of 0.01 mg. Capacity is reduced to between 52 and 120 g because resolution and range trade against each other. Repeatability is about 0.015 to 0.03 mg, giving a minimum weight of roughly 20 to 30 mg at 0.1 percent tolerance. Stabilization takes 4 to 8 seconds, and the site must be very stable, preferably on an anti-vibration table with minimal temperature fluctuation. Internal calibration and antistatic options are common. The balance is typically used where sample amounts are small or costly, such as reference standards and potency assays.

How does it work?

Most analytical balances use electromagnetic force restoration. A weighing pan is attached to a lever system or monolithic cell, and a coil in a permanent magnetic field generates the force that returns the pan to its reference position. The coil current needed to do this is proportional to the load and is converted by an analog-to-digital converter into a mass reading. Optical or inductive sensors detect pan position. A draft shield isolates the pan from air currents, and temperature sensors compensate drift. Internal calibration uses a built-in reference mass driven by a motor, while external calibration uses a traceable weight placed by the operator. Leveling feet and a level indicator ensure the pan is vertical. Electronics apply filters to stabilize readings against vibration.

What are the key features?

  • 0.01 mg readability with high-resolution force-restoration cell
  • Fully enclosed draft shield with anti-static glass option
  • Low minimum weight for small reference standard samples
  • Internal calibration available for temperature-triggered adjustment
  • Built-in ionizer option to neutralize static on vials and powders

What are the technical specifications?

A typical semi-micro analytical balance configuration offers readability of 0.01 mg, capacity of 52–120 g, repeatability (SD) of ≤ 0.015–0.03 mg, linearity of ±0.05–0.1 mg, minimum weight (0.1% tolerance) of ≈ 20–30 mg and stabilization time of ≈ 4–8 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Semi-Micro Analytical Balance is used in reference standard weighing, impurity and potency assays, content uniformity sample preparation and small-quantity catalyst and material weighing. Across the wider Analytical Balances class, laboratories also deploy it for pharmaceutical QC weighing, standard solution preparation and gravimetric analysis.

Which standards and certifications apply?

Relevant standards and methods include USP <41>, USP <1251>, OIML R 76-1, Ph. Eur. 2.1.7, ASTM E898, GB/T 26497 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and OIML R 76 type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the balance on a rigid, vibration-free bench away from doors, air conditioning vents, direct sunlight and heat sources. Allow warm-up of at least 30 minutes to a few hours before use, as specified by the manufacturer. Level the balance and calibrate after every move. Routine checks with certified weights, plus periodic calibration by an accredited service, support compliance with pharmacopoeial requirements. Keep the pan and chamber clean, and avoid placing samples directly on the pan. Control humidity roughly between 40 and 60 percent to limit static and drift. Use antistatic accessories for powders. Record routine tests, eccentricity and repeatability to support quality audits.

How do I select the right Semi-Micro Analytical Balance?

Select a semi-micro balance when sample masses are below about 50 mg or when tolerance requirements exceed what a 0.1 mg unit can achieve. Its site demands are stricter and capacity is lower than standard models. In the RFQ, specify readability, minimum weight at tolerance, capacity, ionizer and calibration type.

How does it compare with other Analytical Balances variants?

Decide readability first. A 0.1 mg balance serves most routine weighing, while 0.01 mg semi-micro models are needed for small samples or minimum weight limits of a few milligrams. Then check capacity, since higher capacity usually reduces repeatability. Consider how calibration will be handled: internal calibration reduces operator effort and drift in variable conditions, while external calibration is cheaper. For regulated laboratories, verify data-integrity software, audit trail and printouts. Automatic draft-shield doors reduce operator influence and static. Also consider the installation site, because vibration, drafts and temperature change affect performance more than the nominal specification. Finally, check the minimum weight at the required tolerance, using the balance's own repeatability data rather than readability alone.

Full specifications

Full specifications
Readability0.01 mg
Capacity52–120 g
Repeatability (SD)≤ 0.015–0.03 mg
Linearity±0.05–0.1 mg
Minimum weight (0.1% tolerance)≈ 20–30 mg
Stabilization time≈ 4–8 s
CalibrationInternal or external
Pan sizeØ 50–80 mm
Draft shieldFully enclosed glass
Operating temperature15–30 C, ≤ 0.5 K/h change

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Reference standard weighing
  • Impurity and potency assays
  • Content uniformity sample preparation
  • Small-quantity catalyst and material weighing

Key features

  • 0.01 mg readability with high-resolution force-restoration cell
  • Fully enclosed draft shield with anti-static glass option
  • Low minimum weight for small reference standard samples
  • Internal calibration available for temperature-triggered adjustment
  • Built-in ionizer option to neutralize static on vials and powders

Frequently asked questions about Semi-Micro Analytical Balance

Use 0.01 mg when samples weigh a few tens of milligrams and a tolerance of 0.1 percent or better is required, for example reference standards or small aliquots. For larger samples above about 100 mg, a 0.1 mg balance is usually adequate.

Request a quotation for the Semi-Micro Analytical Balance

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote