Hydride Generation Accessories for Atomic Absorption
原子吸收氢化物发生附件
- SKU AAA-0005
- AAS Accessories
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Elements | As, Se, Sb, Bi, Sn, Hg |
|---|---|
| Operation modes | continuous flow, flow injection, batch |
| Quartz cell temperature | 800–900 °C |
| Reductant | sodium borohydride |
| Carrier gas | argon or nitrogen |
| Detection limit | 0.05–0.5 µg/L |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification
What is the Hydride Generation Accessories for Atomic Absorption?
Hydride generation accessories add volatile-element capability to an existing atomic absorption spectrometer. They are chosen to measure arsenic, selenium, antimony and mercury at very low trace levels without purchasing a separate dedicated analyzer.
What is the Hydride Generation Accessories for Atomic Absorption?
Hydride generation accessories add volatile-element capability to an existing atomic absorption spectrometer. They are chosen to measure arsenic, selenium, antimony and mercury at very low trace levels without purchasing a separate dedicated analyzer.
Overview
This accessory kit includes a reaction manifold, peristaltic pumps or a reaction vessel, a gas-liquid separator, tubing, and a heated quartz cell that mounts in the atomizer compartment. Sample and reagents are mixed to generate volatile hydrides or cold mercury vapor, which are swept by carrier gas into the cell for atomic absorption measurement. Kits are available for continuous flow, flow injection or batch operation and are matched to specific spectrometer models. Installation typically requires a gas supply, waste handling and a quartz cell aligned in the light path. The accessory extends the detection range of flame or furnace instruments and can be combined with an autosampler. Performance depends on reagent preparation, tubing condition and careful control of reaction conditions.
How does it work?
Accessories determine the practical performance of an atomic absorption instrument. Light sources must emit the correct resonance line with sufficient intensity and stability; hollow-cathode and electrodeless discharge lamps are selected by element and current range. Atomizers convert the sample into free atoms, and their condition strongly affects sensitivity and precision. Graphite tubes and platforms are consumables whose coating, geometry and number of firings set detection limits and tube life. Burner heads and nebulizers control aerosol formation and flame stability, and worn components cause noise, drift and poor recovery. Autosamplers provide reproducible sample and modifier delivery, and hydride manifolds add volatile-element capability. Choosing the right accessory for the element, matrix and instrument model, and replacing consumables on schedule, is essential for valid results.
What are the key features?
- Reaction manifold and gas-liquid separator
- Heated quartz cell for the atomizer compartment
- Continuous flow, flow injection or batch formats
- Adds arsenic, selenium and antimony capability
- Cold vapor option for mercury
- Compatible with autosamplers and existing spectrometers
What are the technical specifications?
A typical hydride generation accessories for atomic absorption configuration offers elements of As, Se, Sb, Bi, Sn, Hg, operation modes of continuous flow, flow injection, batch, quartz cell temperature of 800–900 °C, reductant of sodium borohydride, carrier gas of argon or nitrogen and detection limit of 0.05–0.5 µg/L. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Hydride Generation Accessories for Atomic Absorption is used in adding arsenic and selenium capability to flame AAS, mercury measurement with a cold vapor option, environmental and food trace element testing and cost-effective upgrade of existing instruments. Across the wider AAS Accessories class, laboratories also deploy it for replacement lamps for element-specific analysis, atomizer consumables for trace-metal programs and automation upgrades for high-throughput laboratories.
Which standards and certifications apply?
Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Consumables degrade with use, and their condition affects accuracy more than many operators expect. Hollow-cathode lamps lose intensity and drift as they age; record lamp hours and replace before performance falls. Graphite tubes develop cracks, change sensitivity and eventually fail; monitor firings and apparent sensitivity. Burner slots clog with salt deposits that cause noise, and nebulizers block or corrode, so clean them regularly. Autosampler tubing stretches and changes volume, requiring scheduled replacement. Keep spare critical parts, especially for high-throughput laboratories, and store lamps and tubes in dry conditions. When replacing parts, verify performance with standards and record the change in the instrument log.
How do I select the right Hydride Generation Accessories for Atomic Absorption?
Select a hydride accessory when volatile elements are needed occasionally and a dedicated analyzer is not justified, and confirm compatibility with your spectrometer model and atomizer compartment. Specify the operating mode, gas supply and whether an autosampler or cold vapor module is required. Budget for quartz cells, tubing and reagents as consumables.
How does it compare with other AAS Accessories variants?
Select accessories by matching them exactly to the instrument model, the element and the matrix. Lamps must be specified for the correct element and compatible socket, and the current range should suit the instrument. Graphite tubes should match the furnace geometry, whether transverse or end heated, and the coating must suit the elements measured, since carbide-forming elements need pyrolytically coated or special tubes. Burner heads and nebulizers must be chosen for the gas mixture and dissolved-solids level. Autosampler capacity and vial type depend on throughput and sample volume. Hydride manifolds must be compatible with the existing gas-liquid separator and quartz cell. Confirm part numbers, expected life and availability of certified performance data before ordering.
Full specifications
| Elements | As, Se, Sb, Bi, Sn, Hg |
|---|---|
| Operation modes | continuous flow, flow injection, batch |
| Quartz cell temperature | 800–900 °C |
| Reductant | sodium borohydride |
| Carrier gas | argon or nitrogen |
| Detection limit | 0.05–0.5 µg/L |
| Sample uptake | 4–8 mL/min |
| Compatible instruments | model specific |
| Waste handling | required |
| Autosampler option | available |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Adding arsenic and selenium capability to flame AAS
- Mercury measurement with a cold vapor option
- Environmental and food trace element testing
- Cost-effective upgrade of existing instruments
Key features
- Reaction manifold and gas-liquid separator
- Heated quartz cell for the atomizer compartment
- Continuous flow, flow injection or batch formats
- Adds arsenic, selenium and antimony capability
- Cold vapor option for mercury
- Compatible with autosamplers and existing spectrometers
Frequently asked questions about Hydride Generation Accessories for Atomic Absorption
No, the quartz cell and manifold must physically fit the atomizer compartment and light path of the specific model. Manufacturers offer kits for their own instruments, and some third-party kits are model specific. Confirm the exact instrument model and mounting requirements before ordering.
The main consumables are quartz cells, peristaltic pump tubing, gas-liquid separator parts, reaction coils and sodium borohydride reagent. Quartz cells cloud over time and need cleaning or replacement, and tubing must be replaced when flow rates drift. Reagent quality directly affects detection limits.
Not always. Some kits include both hydride and cold vapor modes, while others require an additional mercury module with a reduction vessel and unheated cell. Confirm the configuration before ordering if mercury is part of your element list, and verify that both modes can be used without cross-contamination.
Performance falls when sensitivity drops, baseline noise rises, or the lamp cannot reach the required current without unstable output. Lamps also fail to ignite or flicker at the end of life. Track accumulated milliamp hours and replace before results degrade, keeping the old lamp until the replacement is verified.
Tube life depends on maximum atomization temperature, total firings, sample acidity, matrix salts and the use of oxygen during cleaning. Halogen or alkaline matrices and high pyrolysis temperatures shorten life. Monitoring sensitivity and peak shape indicates when a tube is near the end of its useful life.
Sometimes, but compatibility depends on physical dimensions, electrical connections and firmware recognition. Lamps are generally interchangeable if the socket and pin configuration match, while tubes, burners and autosampler trays are model specific. Confirm the exact instrument model and part number before ordering to avoid damage or invalid results.