Direct Mercury Analyzer with Thermal Decomposition and Amalgamation
热分解金汞齐化直接测汞仪
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

金汞齐化水中总汞分析仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Detection limit | 0.5–5 ng/L |
|---|---|
| Measurement range | 1–1000 ng/L |
| Sample volume | 10–100 mL |
| Oxidation | bromine chloride or UV oxidation |
| Amalgamation | gold trap |
| Detector | cold vapor AAS or AFS |
By Lab Manufacturers China Technical TeamLast reviewed Standards: US EPA Method 7473 Mercury in solids and solutions by thermal decomposition, US EPA Method 7470A Mercury in liquid waste by cold vapor AAS, US EPA Method 1631 Mercury in water by oxidation, purge and trap, and CVAFS
A total mercury analyzer for water combines oxidation, reduction, gold amalgamation and detection to measure total mercury in water automatically. It is chosen for routine water monitoring with low detection limits and high sample throughput.
A total mercury analyzer for water combines oxidation, reduction, gold amalgamation and detection to measure total mercury in water automatically. It is chosen for routine water monitoring with low detection limits and high sample throughput.
This benchtop analyzer automates the full method for water: sample and reagents are mixed and heated to oxidize all mercury species, the digest is reduced to elemental mercury, and the vapor is purged onto a gold trap. The trap is heated and mercury is detected by cold vapor atomic absorption or fluorescence. Because oxidation converts organomercury compounds and particulate mercury into a measurable form, the result is total mercury rather than only dissolved elemental mercury. Autosamplers handle sample series, and calibration uses aqueous standards or a gas-phase generator. Detection limits range roughly from 0.5 to 5 nanograms per litre depending on the detector and sample volume. The instrument is used for drinking water, wastewater, surface water and seawater monitoring under methods such as US EPA Method 1631 and ISO 12846.
Mercury is unique among metals because it is volatile at room temperature and forms a stable amalgam with gold. Most analyzers exploit one or both properties. In cold vapor atomic absorption, mercury in solution is reduced to elemental form with tin chloride or sodium borohydride and swept into an absorption cell where it absorbs the 253.7 nanometre line of a mercury lamp. Cold vapor atomic fluorescence uses the same generation step but detects emitted light at right angles for higher sensitivity. Direct analyzers heat the solid or liquid sample to release mercury, which is collected on a gold amalgamator, then desorbed into a detector. Ambient air and emission monitors use gold amalgamation or optical techniques such as Zeeman atomic absorption or ultraviolet absorption for continuous measurement. Calibration uses certified mercury standards and gas-phase generators, and all systems require careful control of contamination because mercury is ubiquitous in laboratories.
A typical total mercury analyzer for water with gold amalgamation configuration offers detection limit of 0.5–5 ng/L, measurement range of 1–1000 ng/L, sample volume of 10–100 mL, oxidation of bromine chloride or UV oxidation, amalgamation of gold trap and detector of cold vapor AAS or AFS. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Total Mercury Analyzer for Water with Gold Amalgamation is used in drinking water and regulatory compliance testing, wastewater and industrial effluent monitoring, surface water, groundwater and seawater and environmental research on mercury cycling. Across the wider Mercury Analyzers class, laboratories also deploy it for mercury in fish, rice, seafood and food products, drinking water, wastewater and seawater monitoring and soil, sediment and contaminated site assessment.
Relevant standards and methods include US EPA Method 7473 Mercury in solids and solutions by thermal decomposition, US EPA Method 7470A Mercury in liquid waste by cold vapor AAS, US EPA Method 1631 Mercury in water by oxidation, purge and trap, and CVAFS, ISO 12846 Water quality — Determination of mercury by AAS after enrichment, ISO 20552 Workplace air — Determination of mercury vapour by gold amalgamation, EN 15852 Stationary source emissions — Determination of total gaseous mercury and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Mercury is toxic by inhalation and accumulates, so laboratories must control vapor exposure, use ventilated enclosures and monitor ambient air. Contamination is a constant risk because mercury appears in reagents, dust and previous samples, so ultrapure reagents, dedicated glassware and rigorous blanks are essential. Gold amalgamators require periodic cleaning or replacement when recovery falls. Calibration standards and gas generators must be traceable, and reducing agents must be fresh. Luminaires and detectors for the 253.7 nanometre line need stable temperature. For emission and ambient monitors, sample lines must be heated and inert to prevent mercury loss. Maintain service records and follow local occupational exposure limits and waste disposal rules.
Select a total mercury water analyzer when automated, low-level mercury measurement of many water samples is required and organomercury species must be included. Specify the detection limit, sample volume and expected sample numbers. Confirm that the oxidation chemistry suits your matrices and that the method matches the regulatory procedure you must follow.
Select a mercury analyzer by sample type and required detection limit. Direct thermal decomposition analyzers handle solid and liquid samples in minutes with minimal preparation and reach low nanogram levels, which suits food, soil and waste testing. Cold vapor atomic absorption is a robust, economical choice for water and digested samples at microgram per litre levels. Cold vapor atomic fluorescence reaches much lower limits and suits ultratrace water and seawater work. Portable ambient air analyzers with gold film or Zeeman detection serve workplace and indoor air surveys. Continuous emission monitors and total mercury analyzers with gold amalgamation are installed on industrial stacks and process streams. Confirm the measurement range, sample throughput, calibration approach and whether a specific regulatory method is mandated.
| Detection limit | 0.5–5 ng/L |
|---|---|
| Measurement range | 1–1000 ng/L |
| Sample volume | 10–100 mL |
| Oxidation | bromine chloride or UV oxidation |
| Amalgamation | gold trap |
| Detector | cold vapor AAS or AFS |
| Carrier gas | argon, 100–400 mL/min |
| Digestion temperature | 60–95 °C |
| Measurement time | 3–10 min per sample |
| Autosampler | up to 60 positions |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Natural waters contain elemental, inorganic and organomercury species such as methylmercury. Oxidation with bromine chloride or ultraviolet light breaks these compounds down to divalent mercury, which can then be reduced to elemental vapor. Without oxidation only part of the mercury would be measured, underreporting total concentration.
With gold amalgamation and atomic fluorescence, detection limits of 0.5 to 1 nanogram per litre are achievable for clean water, while atomic absorption systems typically reach 1 to 5 nanograms per litre. The practical limit is set by blank contamination and sample volume more than by the detector itself.
Every batch includes method blanks carried through oxidation, reduction and trapping, and reagent lots are screened for mercury. Dedicated glassware, clean benches and ultrapure reagents reduce blanks. A batch is valid only when blanks are below a defined fraction of the reporting limit defined in the method.
Mercury vapor forms a stable amalgam with gold at room temperature and is released when the gold is heated. Trapping mercury on gold concentrates it from a large sample volume or gas stream and separates it from interfering substances, which greatly lowers detection limits. Amalgamators are central to direct analyzers and sensitive ambient monitors.
Water samples for mercury are usually acidified and oxidized, kept in glass or fluoropolymer containers, and analyzed quickly because mercury can be lost or converted. Solid samples are dried or frozen and ground in equipment free of mercury and cross-contamination. Sample containers, field blanks and holding times are defined in the applicable method.
Mercury occurs in laboratory dust, some reagents and residues from previous samples, and it adsorbs onto surfaces. At the ultratrace levels measured, tiny amounts cause large errors. Dedicated glassware, ultrapure reagents, clean benches, heated sweep lines and frequent method blanks are used to keep contamination under control.

热分解金汞齐化直接测汞仪