Hollow-Cathode Lamps for Atomic Absorption
原子吸收空心阴极灯
- SKU AAA-0001
- AAS Accessories
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Element-specific performance test (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Element coverage | most metals and some non-metals |
|---|---|
| Wavelength range | 185–900 nm |
| Recommended current | 5–25 mA typical |
| Maximum current | 15–40 mA |
| Rated life | 500–3000 mAh |
| Warm-up time | 15–30 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification
What is the Hollow-Cathode Lamps for Atomic Absorption?
Hollow-cathode lamps are element-specific line sources for atomic absorption spectrometers. Each lamp emits the sharp resonance lines of one element and is the standard light source for flame and graphite furnace measurements.
What is the Hollow-Cathode Lamps for Atomic Absorption?
Hollow-cathode lamps are element-specific line sources for atomic absorption spectrometers. Each lamp emits the sharp resonance lines of one element and is the standard light source for flame and graphite furnace measurements.
Overview
A hollow-cathode lamp consists of a sealed glass envelope with a cathode made of or containing the target element and an anode in a low-pressure inert gas. When a voltage is applied, ions bombard the cathode and sputter atoms that are excited and emit the element characteristic lines. The emission is very narrow, which gives atomic absorption its selectivity. Lamps are made for most elements and are coded for socket type; some are interchangeable across instruments with matching pin configurations. Useful life is measured in milliamp hours, and running at higher current increases intensity but shortens life and can broaden lines. A warm-up period of 15 to 30 minutes is usually required for stable output, and alignment in the lamp compartment affects sensitivity. Proper storage and handling of the window protect performance.
How does it work?
Accessories determine the practical performance of an atomic absorption instrument. Light sources must emit the correct resonance line with sufficient intensity and stability; hollow-cathode and electrodeless discharge lamps are selected by element and current range. Atomizers convert the sample into free atoms, and their condition strongly affects sensitivity and precision. Graphite tubes and platforms are consumables whose coating, geometry and number of firings set detection limits and tube life. Burner heads and nebulizers control aerosol formation and flame stability, and worn components cause noise, drift and poor recovery. Autosamplers provide reproducible sample and modifier delivery, and hydride manifolds add volatile-element capability. Choosing the right accessory for the element, matrix and instrument model, and replacing consumables on schedule, is essential for valid results.
What are the key features?
- Element-specific cathode for sharp resonance lines
- Sealed envelope with low-pressure inert gas
- Available for most metallic elements
- Life rated in milliamp hours
- Coded sockets for instrument compatibility
- Warm-up of 15 to 30 minutes for stability
What are the technical specifications?
A typical hollow-cathode lamps for atomic absorption configuration offers element coverage of most metals and some non-metals, wavelength range of 185–900 nm, recommended current of 5–25 mA typical, maximum current of 15–40 mA, rated life of 500–3000 mAh and warm-up time of 15–30 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Hollow-Cathode Lamps for Atomic Absorption is used in flame and graphite furnace element measurements, lithium and potassium analysis in clinical samples, trace metals in water and environmental samples and teaching and method development. Across the wider AAS Accessories class, laboratories also deploy it for replacement lamps for element-specific analysis, atomizer consumables for trace-metal programs and automation upgrades for high-throughput laboratories.
Which standards and certifications apply?
Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Element-specific performance test; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Consumables degrade with use, and their condition affects accuracy more than many operators expect. Hollow-cathode lamps lose intensity and drift as they age; record lamp hours and replace before performance falls. Graphite tubes develop cracks, change sensitivity and eventually fail; monitor firings and apparent sensitivity. Burner slots clog with salt deposits that cause noise, and nebulizers block or corrode, so clean them regularly. Autosampler tubing stretches and changes volume, requiring scheduled replacement. Keep spare critical parts, especially for high-throughput laboratories, and store lamps and tubes in dry conditions. When replacing parts, verify performance with standards and record the change in the instrument log.
How do I select the right Hollow-Cathode Lamps for Atomic Absorption?
Select a hollow-cathode lamp by the exact element and by the socket and current rating your instrument requires. Confirm the part number matches the spectrometer model. For elements with weak resonance lines or volatile elements, compare a boosted or electrodeless lamp if higher intensity is needed. Record installation date and accumulate lamp hours.
How does it compare with other AAS Accessories variants?
Select accessories by matching them exactly to the instrument model, the element and the matrix. Lamps must be specified for the correct element and compatible socket, and the current range should suit the instrument. Graphite tubes should match the furnace geometry, whether transverse or end heated, and the coating must suit the elements measured, since carbide-forming elements need pyrolytically coated or special tubes. Burner heads and nebulizers must be chosen for the gas mixture and dissolved-solids level. Autosampler capacity and vial type depend on throughput and sample volume. Hydride manifolds must be compatible with the existing gas-liquid separator and quartz cell. Confirm part numbers, expected life and availability of certified performance data before ordering.
Full specifications
| Element coverage | most metals and some non-metals |
|---|---|
| Wavelength range | 185–900 nm |
| Recommended current | 5–25 mA typical |
| Maximum current | 15–40 mA |
| Rated life | 500–3000 mAh |
| Warm-up time | 15–30 min |
| Window material | quartz or borosilicate |
| Socket type | 2-pin or coded |
| Spectral bandwidth | 0.001–0.01 nm |
| Compatibility | model specific |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Flame and graphite furnace element measurements
- Lithium and potassium analysis in clinical samples
- Trace metals in water and environmental samples
- Teaching and method development
Key features
- Element-specific cathode for sharp resonance lines
- Sealed envelope with low-pressure inert gas
- Available for most metallic elements
- Life rated in milliamp hours
- Coded sockets for instrument compatibility
- Warm-up of 15 to 30 minutes for stability
Frequently asked questions about Hollow-Cathode Lamps for Atomic Absorption
Multi-element lamps contain several elements in one cathode, but they often compromise intensity, cause spectral overlap and have shorter life. Most methods use a single-element lamp for each element. Single-element lamps give the best sensitivity and are easier to troubleshoot.
Higher current increases emission intensity but also broadens the resonance line and sputters more cathode material, which reduces sensitivity and shortens lamp life. Each lamp has a recommended and a maximum current. Setting current within the recommended range balances signal-to-noise against lamp life.
Store lamps in a dry, clean place at room temperature, protected from dust and mechanical shock, and avoid touching the window with bare fingers. Some laboratories store lamps in the instrument turret, which is acceptable if the compartment is clean. Note the accumulated hours on each lamp.
Performance falls when sensitivity drops, baseline noise rises, or the lamp cannot reach the required current without unstable output. Lamps also fail to ignite or flicker at the end of life. Track accumulated milliamp hours and replace before results degrade, keeping the old lamp until the replacement is verified.
Tube life depends on maximum atomization temperature, total firings, sample acidity, matrix salts and the use of oxygen during cleaning. Halogen or alkaline matrices and high pyrolysis temperatures shorten life. Monitoring sensitivity and peak shape indicates when a tube is near the end of its useful life.
Sometimes, but compatibility depends on physical dimensions, electrical connections and firmware recognition. Lamps are generally interchangeable if the socket and pin configuration match, while tubes, burners and autosampler trays are model specific. Confirm the exact instrument model and part number before ordering to avoid damage or invalid results.