Electrodeless Discharge Lamps for Atomic Absorption

原子吸收无极放电灯

  • SKU AAA-0002
  • AAS Accessories
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • Element-specific performance test (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
ElementsAs, Se, Sb, Bi, Cd, Hg, P, Te
Excitationradio frequency or microwave
Intensityhigher than hollow-cathode lamps
Warm-up time15–40 min
Lamp power5–20 W
Envelope materialsealed quartz bulb
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification

What is the Electrodeless Discharge Lamps for Atomic Absorption?

Electrodeless discharge lamps are high-intensity line sources used for volatile and weak-line elements. They are chosen when hollow-cathode lamps give insufficient signal-to-noise or unstable output for elements such as arsenic and selenium.

What is the Electrodeless Discharge Lamps for Atomic Absorption?

Electrodeless discharge lamps are high-intensity line sources used for volatile and weak-line elements. They are chosen when hollow-cathode lamps give insufficient signal-to-noise or unstable output for elements such as arsenic and selenium.

Overview

An electrodeless discharge lamp contains a small amount of the element or its salt in a sealed quartz bulb, excited by a radio-frequency or microwave field from an external coil. The discharge emits intense resonance lines without electrodes, which avoids sputtering and gives higher intensity than a hollow-cathode lamp for many volatile elements. The lamp requires a dedicated power supply and warm-up, and intensity may need stabilization. Elements such as arsenic, selenium, antimony, bismuth, cadmium, mercury, phosphorus and tellurium benefit most. Electrodeless lamps can improve detection limits and reduce noise, but they cost more, have shorter life in some cases and need careful handling because the bulb is fragile. They are usually installed alongside hollow-cathode lamps and selected per element in the method software.

How does it work?

Accessories determine the practical performance of an atomic absorption instrument. Light sources must emit the correct resonance line with sufficient intensity and stability; hollow-cathode and electrodeless discharge lamps are selected by element and current range. Atomizers convert the sample into free atoms, and their condition strongly affects sensitivity and precision. Graphite tubes and platforms are consumables whose coating, geometry and number of firings set detection limits and tube life. Burner heads and nebulizers control aerosol formation and flame stability, and worn components cause noise, drift and poor recovery. Autosamplers provide reproducible sample and modifier delivery, and hydride manifolds add volatile-element capability. Choosing the right accessory for the element, matrix and instrument model, and replacing consumables on schedule, is essential for valid results.

What are the key features?

  • Electrodeless radio-frequency or microwave excitation
  • Higher intensity than hollow-cathode lamps for volatile elements
  • No sputtering, extending source stability
  • Best for As, Se, Sb, Bi, Cd, Hg, P and Te
  • Dedicated power supply and warm-up required
  • Fragile quartz bulb needing careful handling

What are the technical specifications?

A typical electrodeless discharge lamps for atomic absorption configuration offers elements of As, Se, Sb, Bi, Cd, Hg, P, Te, excitation of radio frequency or microwave, intensity of higher than hollow-cathode lamps, warm-up time of 15–40 min, lamp power of 5–20 W and envelope material of sealed quartz bulb. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Electrodeless Discharge Lamps for Atomic Absorption is used in arsenic and selenium at low concentrations, cadmium and mercury trace analysis, phosphorus determination in water and biological samples and methods requiring low lamp noise. Across the wider AAS Accessories class, laboratories also deploy it for replacement lamps for element-specific analysis, atomizer consumables for trace-metal programs and automation upgrades for high-throughput laboratories.

Which standards and certifications apply?

Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Element-specific performance test; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Consumables degrade with use, and their condition affects accuracy more than many operators expect. Hollow-cathode lamps lose intensity and drift as they age; record lamp hours and replace before performance falls. Graphite tubes develop cracks, change sensitivity and eventually fail; monitor firings and apparent sensitivity. Burner slots clog with salt deposits that cause noise, and nebulizers block or corrode, so clean them regularly. Autosampler tubing stretches and changes volume, requiring scheduled replacement. Keep spare critical parts, especially for high-throughput laboratories, and store lamps and tubes in dry conditions. When replacing parts, verify performance with standards and record the change in the instrument log.

How do I select the right Electrodeless Discharge Lamps for Atomic Absorption?

Select an electrodeless discharge lamp when better signal-to-noise is needed for volatile or weak-line elements and the instrument supports the dedicated supply. Confirm the correct element, power range and compatibility with your spectrometer. Handle the quartz bulb carefully and keep a hollow-cathode lamp available as a backup.

How does it compare with other AAS Accessories variants?

Select accessories by matching them exactly to the instrument model, the element and the matrix. Lamps must be specified for the correct element and compatible socket, and the current range should suit the instrument. Graphite tubes should match the furnace geometry, whether transverse or end heated, and the coating must suit the elements measured, since carbide-forming elements need pyrolytically coated or special tubes. Burner heads and nebulizers must be chosen for the gas mixture and dissolved-solids level. Autosampler capacity and vial type depend on throughput and sample volume. Hydride manifolds must be compatible with the existing gas-liquid separator and quartz cell. Confirm part numbers, expected life and availability of certified performance data before ordering.

Full specifications

Full specifications
ElementsAs, Se, Sb, Bi, Cd, Hg, P, Te
Excitationradio frequency or microwave
Intensityhigher than hollow-cathode lamps
Warm-up time15–40 min
Lamp power5–20 W
Envelope materialsealed quartz bulb
Rated life300–1500 h
Power supplydedicated external unit
WindowUV-grade quartz
Compatibilitymodel specific

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Arsenic and selenium at low concentrations
  • Cadmium and mercury trace analysis
  • Phosphorus determination in water and biological samples
  • Methods requiring low lamp noise

Key features

  • Electrodeless radio-frequency or microwave excitation
  • Higher intensity than hollow-cathode lamps for volatile elements
  • No sputtering, extending source stability
  • Best for As, Se, Sb, Bi, Cd, Hg, P and Te
  • Dedicated power supply and warm-up required
  • Fragile quartz bulb needing careful handling

Frequently asked questions about Electrodeless Discharge Lamps for Atomic Absorption

Elements with weak resonance lines or high volatility benefit most, including arsenic, selenium, antimony, bismuth, cadmium, mercury, phosphorus and tellurium. Their detection limits often improve when the higher-intensity source reduces baseline noise. Routine strong-line elements usually work well with hollow-cathode lamps.

Related models

All AAS Accessories

Request a quotation for the Electrodeless Discharge Lamps for Atomic Absorption