Autosamplers for Atomic Absorption
原子吸收自动进样器
- SKU AAA-0004
- AAS Accessories
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- 21 CFR Part 11 software compatibility (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Vial capacity | 30–180 positions |
|---|---|
| Sample volume range | 1–100 µL |
| Modifier positions | 1–3 |
| Dilution capability | automatic, up to 100:1 |
| Carry-over | ≤ 0.1% with rinse |
| Probe material | PTFE or inert polymer |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification
What is the Autosamplers for Atomic Absorption?
Autosamplers for atomic absorption deliver samples, standards and modifiers in programmed sequences. They are chosen to improve reproducibility, increase throughput and reduce operator exposure during long runs in flame and furnace laboratories.
What is the Autosamplers for Atomic Absorption?
Autosamplers for atomic absorption deliver samples, standards and modifiers in programmed sequences. They are chosen to improve reproducibility, increase throughput and reduce operator exposure during long runs in flame and furnace laboratories.
Overview
An autosampler positions a probe over a series of vials and delivers a measured volume to the flame nebulizer or into a graphite tube injection hole. For furnace work it also adds matrix modifier, diluent and standard addition volumes directly into the tube, mixing them with an air or argon bubble. Ribbon or tray designs hold from about 30 to 180 vials, and cooling options preserve volatile standards or enzymes. Software defines calibration order, QC placement and reanalysis rules, and correlates results with sample identities. Consistent probe depth, rinse cycles and pump tubing condition determine carry-over and precision. Because tubing stretches and probes clog, preventive replacement is part of routine maintenance. Autosamplers are the single most effective accessory for freeing operator time in AAS laboratories.
How does it work?
Accessories determine the practical performance of an atomic absorption instrument. Light sources must emit the correct resonance line with sufficient intensity and stability; hollow-cathode and electrodeless discharge lamps are selected by element and current range. Atomizers convert the sample into free atoms, and their condition strongly affects sensitivity and precision. Graphite tubes and platforms are consumables whose coating, geometry and number of firings set detection limits and tube life. Burner heads and nebulizers control aerosol formation and flame stability, and worn components cause noise, drift and poor recovery. Autosamplers provide reproducible sample and modifier delivery, and hydride manifolds add volatile-element capability. Choosing the right accessory for the element, matrix and instrument model, and replacing consumables on schedule, is essential for valid results.
What are the key features?
- Programmable probe positioning over vial trays
- Modifier, diluent and standard addition dosing
- Capacity of about 30 to 180 vials
- Rinse cycles and low carry-over design
- Software calibration, QC and reanalysis
- Optional cooling for volatile standards
What are the technical specifications?
A typical autosamplers for atomic absorption configuration offers vial capacity of 30–180 positions, sample volume range of 1–100 µL, modifier positions of 1–3, dilution capability of automatic, up to 100:1, carry-over of ≤ 0.1% with rinse and probe material of PTFE or inert polymer. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Autosamplers for Atomic Absorption is used in high-throughput flame AAS sequences, graphite furnace standard addition automation, regulated laboratories needing traceability and reducing operator contact with samples. Across the wider AAS Accessories class, laboratories also deploy it for replacement lamps for element-specific analysis, atomizer consumables for trace-metal programs and automation upgrades for high-throughput laboratories.
Which standards and certifications apply?
Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compatibility; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Consumables degrade with use, and their condition affects accuracy more than many operators expect. Hollow-cathode lamps lose intensity and drift as they age; record lamp hours and replace before performance falls. Graphite tubes develop cracks, change sensitivity and eventually fail; monitor firings and apparent sensitivity. Burner slots clog with salt deposits that cause noise, and nebulizers block or corrode, so clean them regularly. Autosampler tubing stretches and changes volume, requiring scheduled replacement. Keep spare critical parts, especially for high-throughput laboratories, and store lamps and tubes in dry conditions. When replacing parts, verify performance with standards and record the change in the instrument log.
How do I select the right Autosamplers for Atomic Absorption?
Select an autosampler with the vial capacity, dilution range and cooling options your workload requires, and confirm it is supported by your instrument model and software. Verify carry-over specifications against your lowest concentration requirements. Budget for replacement tubing, probes and trays as regular consumables.
How does it compare with other AAS Accessories variants?
Select accessories by matching them exactly to the instrument model, the element and the matrix. Lamps must be specified for the correct element and compatible socket, and the current range should suit the instrument. Graphite tubes should match the furnace geometry, whether transverse or end heated, and the coating must suit the elements measured, since carbide-forming elements need pyrolytically coated or special tubes. Burner heads and nebulizers must be chosen for the gas mixture and dissolved-solids level. Autosampler capacity and vial type depend on throughput and sample volume. Hydride manifolds must be compatible with the existing gas-liquid separator and quartz cell. Confirm part numbers, expected life and availability of certified performance data before ordering.
Full specifications
| Vial capacity | 30–180 positions |
|---|---|
| Sample volume range | 1–100 µL |
| Modifier positions | 1–3 |
| Dilution capability | automatic, up to 100:1 |
| Carry-over | ≤ 0.1% with rinse |
| Probe material | PTFE or inert polymer |
| Cooling option | 4–10 °C tray |
| Compatible instruments | model specific |
| Tray type | round or rectangular |
| Control | instrument software |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- High-throughput flame AAS sequences
- Graphite furnace standard addition automation
- Regulated laboratories needing traceability
- Reducing operator contact with samples
Key features
- Programmable probe positioning over vial trays
- Modifier, diluent and standard addition dosing
- Capacity of about 30 to 180 vials
- Rinse cycles and low carry-over design
- Software calibration, QC and reanalysis
- Optional cooling for volatile standards
Frequently asked questions about Autosamplers for Atomic Absorption
The probe is rinsed in a dedicated rinse solution between samples, and software can add additional rinses after high-concentration standards. Short, smooth tubing, correct probe depth and proper immersion depth reduce residual sample. Carry-over is verified during method validation at the lowest calibration level.
Peristaltic pump tubing stretches and hardens with use, which changes the delivered volume and causes drift in sensitivity and dilution accuracy. Replacing tubing on the manufacturer recommended interval, or when flow checks fail, keeps volumes accurate. Record replacement dates with the instrument log.
Yes, furnace autosamplers commonly add the sample plus several standard volumes into the same tube, mixing them before the heating program. This builds the standard addition curve automatically for each sample. The volumes and mixing must be validated for accuracy and reproducibility.
Performance falls when sensitivity drops, baseline noise rises, or the lamp cannot reach the required current without unstable output. Lamps also fail to ignite or flicker at the end of life. Track accumulated milliamp hours and replace before results degrade, keeping the old lamp until the replacement is verified.
Tube life depends on maximum atomization temperature, total firings, sample acidity, matrix salts and the use of oxygen during cleaning. Halogen or alkaline matrices and high pyrolysis temperatures shorten life. Monitoring sensitivity and peak shape indicates when a tube is near the end of its useful life.
Sometimes, but compatibility depends on physical dimensions, electrical connections and firmware recognition. Lamps are generally interchangeable if the socket and pin configuration match, while tubes, burners and autosampler trays are model specific. Confirm the exact instrument model and part number before ordering to avoid damage or invalid results.