By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14212 (SO2), EN 14211 (NOx), EN 14626 (CO)

Standards referenced

  • EN 14212 (SO2)
  • EN 14211 (NOx)
  • EN 14626 (CO)
  • ISO 13964 (ozone)
  • US EPA 40 CFR Part 50 Appendix A
  • HJ 654

What are Gas Analyzers?

Gas analyzers measure the concentration of specific gases such as sulfur dioxide, nitrogen oxides, carbon monoxide and ozone in ambient air. They are used by air quality monitoring networks, industrial plants and regulators to compare concentrations with health-based standards and to track pollution trends over time.

5 models of Gas Analyzers

The 5 models below are current configurations; specifications are confirmed on quotation.

UV Fluorescence SO2 Analyzer

紫外荧光二氧化硫分析仪

  • GAA-0001
  • Gas Analyzers
  • CE (to be confirmed)
  • China environmental monitoring instrument certification (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
UV fluorescence at 214 nm
Measurement range:
0–500 ppb, 0–2000 ppb selectable
Lower detection limit:
0.4 ppb (2σ)
Response time:
≤ 60 s to 95%
Zero drift:
< 1 ppb per 24 h
Span drift:
< 1% per 24 h

A reference-grade analyzer that measures sulfur dioxide in ambient air by ultraviolet fluorescence. It is the standard choice for regulatory air quality networks and for tracking SO2 near combustion and smelting sources.

Request a quote
View details

Chemiluminescence NOx Analyzer

化学发光氮氧化物分析仪

  • GAA-0002
  • Gas Analyzers
  • CE (to be confirmed)
  • China environmental monitoring instrument certification (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
Chemiluminescence with ozone
Measured species:
NO, NO2, NOx
Measurement range:
0–500 ppb, 0–2000 ppb selectable
Lower detection limit:
0.4 ppb (2σ)
Response time:
≤ 60 s to 95%
NO2 converter:
Molybdenum, heated, or photolytic

A reference-grade analyzer that measures nitric oxide, nitrogen dioxide and total nitrogen oxides in ambient air by chemiluminescence. It is the standard instrument for regulatory NOx monitoring in urban, roadside and industrial monitoring networks.

Request a quote
View details

NDIR Carbon Monoxide Analyzer

非分散红外一氧化碳分析仪

  • GAA-0003
  • Gas Analyzers
  • CE (to be confirmed)
  • China environmental monitoring instrument certification (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
Non-dispersive infrared with gas filter correlation
Absorption wavelength:
4.6 µm
Measurement range:
0–50 ppm, 0–200 ppm selectable
Lower detection limit:
0.04 ppm (2σ)
Response time:
≤ 60 s to 95%
Zero drift:
< 0.1 ppm per 24 h

A reference-grade analyzer that measures carbon monoxide in ambient air by non-dispersive infrared absorption. It is widely used in traffic-related, tunnel and urban air quality networks where CO serves as a key combustion marker.

Request a quote
View details

UV Photometric Ozone Analyzer

紫外光度臭氧分析仪

  • GAA-0004
  • Gas Analyzers
  • CE (to be confirmed)
  • China environmental monitoring instrument certification (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
UV absorption at 254 nm
Measurement range:
0–500 ppb, 0–2000 ppb selectable
Lower detection limit:
0.5 ppb (2σ)
Response time:
≤ 20 s to 95%
Zero noise:
0.25 ppb RMS
Light source:
Mercury lamp, 254 nm

A reference-grade analyzer that measures ozone in ambient air by absorption of 254 nm ultraviolet light. It is the standard instrument for regulatory ozone monitoring networks and for photochemical smog and summer haze studies.

Request a quote
View details

Electrochemical Multi-Gas Air Quality Analyzer

电化学多组分空气质量分析仪

  • GAA-0005
  • Gas Analyzers
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Measurement principle:
Electrochemical cells, plug-in
Measured gases:
SO2, NO2, O3, CO, H2S, optional VOC
SO2 range:
0–20 ppm
NO2 range:
0–20 ppm
O3 range:
0–20 ppm
CO range:
0–1000 ppm

A compact analyzer with interchangeable electrochemical sensors that measures several gases such as SO2, NO2, O3, CO and H2S at once. It is the right choice for screening, indoor checks and dense low-cost monitoring networks.

Request a quote
View details

Compare Gas Analyzers models

ModelMeasurement principleMeasurement rangeLower detection limitResponse timeZero drift
UV Fluorescence SO2 AnalyzerGAA-0001UV fluorescence at 214 nm0–500 ppb, 0–2000 ppb selectable0.4 ppb (2σ)≤ 60 s to 95%< 1 ppb per 24 h
Chemiluminescence NOx AnalyzerGAA-0002Chemiluminescence with ozone0–500 ppb, 0–2000 ppb selectable0.4 ppb (2σ)≤ 60 s to 95%—
NDIR Carbon Monoxide AnalyzerGAA-0003Non-dispersive infrared with gas filter correlation0–50 ppm, 0–200 ppm selectable0.04 ppm (2σ)≤ 60 s to 95%< 0.1 ppm per 24 h
UV Photometric Ozone AnalyzerGAA-0004UV absorption at 254 nm0–500 ppb, 0–2000 ppb selectable0.5 ppb (2σ)≤ 20 s to 95%—
Electrochemical Multi-Gas Air Quality AnalyzerGAA-0005Electrochemical cells, plug-in—5–20 ppb, gas dependent30–60 s—

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Gas Analyzers work?

Ambient gas analyzers use a selective physical or chemical reaction to convert a gas concentration into an electrical signal. Sulfur dioxide is measured by ultraviolet fluorescence, where SO2 molecules excited at 214 nm emit light whose intensity is proportional to concentration. Nitrogen oxides are determined by chemiluminescence, reacting nitric oxide with ozone to produce light, with a molybdenum converter reducing NO2 to NO for the total. Carbon monoxide is measured by non-dispersive infrared absorption, often with gas filter correlation to reject interference. Ozone is determined by ultraviolet absorption at 254 nm in a dual-cell or single-cell design that alternates sample and scrubbed air. Sample conditioning removes particles and moisture, and internal computers apply zero and span corrections for temperature and pressure.

Which Gas Analyzers variants are available?

  • UV Fluorescence SO2 Analyzer — A reference-grade analyzer that measures sulfur dioxide in ambient air by ultraviolet fluorescence.
  • Chemiluminescence NOx Analyzer — A reference-grade analyzer that measures nitric oxide, nitrogen dioxide and total nitrogen oxides in ambient air by chemiluminescence.
  • NDIR Carbon Monoxide Analyzer — A reference-grade analyzer that measures carbon monoxide in ambient air by non-dispersive infrared absorption.
  • UV Photometric Ozone Analyzer — A reference-grade analyzer that measures ozone in ambient air by absorption of 254 nm ultraviolet light.
  • Electrochemical Multi-Gas Air Quality Analyzer — A compact analyzer with interchangeable electrochemical sensors that measures several gases such as SO2, NO2, O3, CO and H2S at once.

How do I choose the right variant?

Choose the analyzer by the gas, the required measurement range and whether the data must satisfy a regulatory method. Reference-grade instruments follow EN or US EPA methods and provide the stability, detection limit and averaging time that monitoring networks require. Range should bracket the local concentrations and include the limit value, for example 0–500 ppb for SO2 and NOx in urban air or 0–50 ppm for CO near traffic. Consider interference rejection, response time, zero and span drift specifications and the calibration gas requirements. For indoor or occupational checks, portable or electrochemical analyzers with lower ranges and simpler calibration often suffice. Confirm output protocols, data logging and the availability of a multipoint calibration system.

Where are Gas Analyzers used?

Gas Analyzers are specified in urban air quality monitoring networks, industrial fence-line and plant perimeter monitoring, roadside and traffic-related pollution studies and indoor air quality and occupational checks.

Which standards and certifications apply?

Work with Gas Analyzers is commonly governed by EN 14212 (SO2), EN 14211 (NOx), EN 14626 (CO), ISO 13964 (ozone), US EPA 40 CFR Part 50 Appendix A and HJ 654. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install analyzers in a temperature-controlled shelter or rack with clean, dry sample lines and a manifold that provides stable flow. Calibrate with certified gas standards and a dynamic dilution system, performing zero and span checks on the schedule required by the method, and keep records of converter efficiency for NOx instruments. Replace particulate filters, dryers and pump diaphragms regularly, and verify sample flow and pressure. Protect optical components from dust and condensation, and allow warm-up and stabilization before reporting data. For regulatory networks, follow quality assurance and quality control procedures such as US EPA 40 CFR Part 58 Appendix A and retain raw data for audit.

Frequently asked questions about Gas Analyzers

Most networks measure sulfur dioxide, nitrogen oxides, carbon monoxide, ozone and particulate matter, with some adding ammonia, hydrogen sulfide and volatile organic compounds. The exact set is defined by the national or regional air quality standard and the local emission sources.

Need help specifying Gas Analyzers?

Request a quote