Electrochemical Multi-Gas Air Quality Analyzer — product photo

Electrochemical Multi-Gas Air Quality Analyzer

电化学多组分空气质量分析仪

  • SKU GAA-0005
  • Gas Analyzers
  • CE (to be confirmed)
  • RoHS (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measurement principleElectrochemical cells, plug-in
Measured gasesSO2, NO2, O3, CO, H2S, optional VOC
SO2 range0–20 ppm
NO2 range0–20 ppm
O3 range0–20 ppm
CO range0–1000 ppm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14212 (SO2), EN 14211 (NOx), EN 14626 (CO)

What is the Electrochemical Multi-Gas Air Quality Analyzer?

A compact analyzer with interchangeable electrochemical sensors that measures several gases such as SO2, NO2, O3, CO and H2S at once. It is the right choice for screening, indoor checks and dense low-cost monitoring networks.

What is the Electrochemical Multi-Gas Air Quality Analyzer?

A compact analyzer with interchangeable electrochemical sensors that measures several gases such as SO2, NO2, O3, CO and H2S at once. It is the right choice for screening, indoor checks and dense low-cost monitoring networks.

Overview

This analyzer houses a set of electrochemical cells, each with a working, counter and reference electrode separated by an electrolyte. Target gas diffuses through a membrane and reacts at the working electrode, producing a current proportional to concentration. Because each cell is selective for one gas, a single enclosure can report SO2, NO2, O3, CO, H2S and sometimes VOC simultaneously. Sensors are plug-in modules that are replaced when depleted, typically after 12 to 24 months, and calibration uses span gases per channel. Response times of 30 to 60 seconds and detection limits in the low parts per billion to low parts per million range suit screening and indicative monitoring rather than reference compliance. Small size, low power and digital outputs make these analyzers useful for street-level networks, indoor air surveys and fence-line hotspots where many points are needed at moderate cost.

How does it work?

Ambient gas analyzers use a selective physical or chemical reaction to convert a gas concentration into an electrical signal. Sulfur dioxide is measured by ultraviolet fluorescence, where SO2 molecules excited at 214 nm emit light whose intensity is proportional to concentration. Nitrogen oxides are determined by chemiluminescence, reacting nitric oxide with ozone to produce light, with a molybdenum converter reducing NO2 to NO for the total. Carbon monoxide is measured by non-dispersive infrared absorption, often with gas filter correlation to reject interference. Ozone is determined by ultraviolet absorption at 254 nm in a dual-cell or single-cell design that alternates sample and scrubbed air. Sample conditioning removes particles and moisture, and internal computers apply zero and span corrections for temperature and pressure.

What are the key features?

  • Interchangeable electrochemical cells measure several gases in one enclosure.
  • Plug-in sensor modules are replaced when depleted without returning the unit.
  • Compact, low-power design suits solar-powered or battery network nodes.
  • Digital and analog outputs integrate with cloud and SCADA platforms.
  • Fast response supports hotspot detection and leak screening.
  • Per-channel span calibration keeps readings traceable to standard gases.

What are the technical specifications?

A typical electrochemical multi-gas air quality analyzer configuration offers measurement principle of Electrochemical cells, plug-in, measured gases of SO2, NO2, O3, CO, H2S, optional VOC, SO2 range of 0–20 ppm, NO2 range of 0–20 ppm, O3 range of 0–20 ppm and CO range of 0–1000 ppm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Electrochemical Multi-Gas Air Quality Analyzer is used in dense street-level air quality networks, indoor air quality and ventilation checks, industrial fence-line hotspot screening and emergency response gas detection. Across the wider Gas Analyzers class, laboratories also deploy it for urban air quality monitoring networks, industrial fence-line and plant perimeter monitoring and roadside and traffic-related pollution studies.

Which standards and certifications apply?

Relevant standards and methods include EN 14212 (SO2), EN 14211 (NOx), EN 14626 (CO), ISO 13964 (ozone), US EPA 40 CFR Part 50 Appendix A and HJ 654. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install analyzers in a temperature-controlled shelter or rack with clean, dry sample lines and a manifold that provides stable flow. Calibrate with certified gas standards and a dynamic dilution system, performing zero and span checks on the schedule required by the method, and keep records of converter efficiency for NOx instruments. Replace particulate filters, dryers and pump diaphragms regularly, and verify sample flow and pressure. Protect optical components from dust and condensation, and allow warm-up and stabilization before reporting data. For regulatory networks, follow quality assurance and quality control procedures such as US EPA 40 CFR Part 58 Appendix A and retain raw data for audit.

How do I select the right Electrochemical Multi-Gas Air Quality Analyzer?

Select this analyzer for indicative monitoring where many measurement points matter more than reference accuracy, such as street networks or indoor surveys. For compliance data, choose single-gas reference analyzers. In an RFQ, specify the gas list, ranges, sensor life, calibration gases and output protocol.

How does it compare with other Gas Analyzers variants?

Choose the analyzer by the gas, the required measurement range and whether the data must satisfy a regulatory method. Reference-grade instruments follow EN or US EPA methods and provide the stability, detection limit and averaging time that monitoring networks require. Range should bracket the local concentrations and include the limit value, for example 0–500 ppb for SO2 and NOx in urban air or 0–50 ppm for CO near traffic. Consider interference rejection, response time, zero and span drift specifications and the calibration gas requirements. For indoor or occupational checks, portable or electrochemical analyzers with lower ranges and simpler calibration often suffice. Confirm output protocols, data logging and the availability of a multipoint calibration system.

Full specifications

Full specifications
Measurement principleElectrochemical cells, plug-in
Measured gasesSO2, NO2, O3, CO, H2S, optional VOC
SO2 range0–20 ppm
NO2 range0–20 ppm
O3 range0–20 ppm
CO range0–1000 ppm
Lower detection limit5–20 ppb, gas dependent
Response time30–60 s
Sensor life12–24 months typical
OutputsRS-485 Modbus, 4–20 mA, optional 4G
Power supply12–24 VDC or 220 VAC adapter

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Dense street-level air quality networks
  • Indoor air quality and ventilation checks
  • Industrial fence-line hotspot screening
  • Emergency response gas detection

Key features

  • Interchangeable electrochemical cells measure several gases in one enclosure.
  • Plug-in sensor modules are replaced when depleted without returning the unit.
  • Compact, low-power design suits solar-powered or battery network nodes.
  • Digital and analog outputs integrate with cloud and SCADA platforms.
  • Fast response supports hotspot detection and leak screening.
  • Per-channel span calibration keeps readings traceable to standard gases.

Frequently asked questions about Electrochemical Multi-Gas Air Quality Analyzer

Most cells last 12 to 24 months in ambient air, depending on exposure to high concentrations and temperature. Output falls as the electrolyte is consumed, so a span check that drops below about 80 percent of the original response indicates replacement.

Related models

All Gas Analyzers

Request a quotation for the Electrochemical Multi-Gas Air Quality Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote