UV Fluorescence SO2 Analyzer
紫外荧光二氧化硫分析仪
- SKU GAA-0001
- Gas Analyzers
- CE (to be confirmed)
- China environmental monitoring instrument certification (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | UV fluorescence at 214 nm |
|---|---|
| Measurement range | 0–500 ppb, 0–2000 ppb selectable |
| Lower detection limit | 0.4 ppb (2σ) |
| Response time | ≤ 60 s to 95% |
| Zero drift | < 1 ppb per 24 h |
| Span drift | < 1% per 24 h |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14212 (SO2), EN 14211 (NOx), EN 14626 (CO)
What is the UV Fluorescence SO2 Analyzer?
A reference-grade analyzer that measures sulfur dioxide in ambient air by ultraviolet fluorescence. It is the standard choice for regulatory air quality networks and for tracking SO2 near combustion and smelting sources.
What is the UV Fluorescence SO2 Analyzer?
A reference-grade analyzer that measures sulfur dioxide in ambient air by ultraviolet fluorescence. It is the standard choice for regulatory air quality networks and for tracking SO2 near combustion and smelting sources.
Overview
The analyzer draws ambient air through a hydrocarbon scrubber and a particulate filter into a fluorescence cell, where a pulsed zinc or cadmium lamp excites SO2 molecules at 214 nm and a photomultiplier measures the emitted light at 300 to 400 nm. A bandpass filter isolates the fluorescence from scattered excitation light. Because the signal is proportional to concentration over several orders of magnitude, the instrument covers low background levels and high urban concentrations with one measurement range, typically 0 to 500 ppb or 0 to 2000 ppb. Internal microprocessors handle temperature and pressure compensation, zero and span correction, and multi-point calibration, while flags mark invalid data during calibration or fault conditions. Aromatic hydrocarbons can cause positive interference, so the scrubber is essential and is replaced on schedule. These instruments form the core of national monitoring networks because their selectivity and stability meet reference method requirements.
How does it work?
Ambient gas analyzers use a selective physical or chemical reaction to convert a gas concentration into an electrical signal. Sulfur dioxide is measured by ultraviolet fluorescence, where SO2 molecules excited at 214 nm emit light whose intensity is proportional to concentration. Nitrogen oxides are determined by chemiluminescence, reacting nitric oxide with ozone to produce light, with a molybdenum converter reducing NO2 to NO for the total. Carbon monoxide is measured by non-dispersive infrared absorption, often with gas filter correlation to reject interference. Ozone is determined by ultraviolet absorption at 254 nm in a dual-cell or single-cell design that alternates sample and scrubbed air. Sample conditioning removes particles and moisture, and internal computers apply zero and span corrections for temperature and pressure.
What are the key features?
- Pulsed UV lamp and photomultiplier give low nanogram-level detection limits.
- Hydrocarbon scrubber removes aromatic interference from traffic and industry.
- Wide linear range covers background and polluted urban concentrations.
- Internal temperature and pressure compensation stabilises readings.
- Automatic zero and span checks record drift against stored values.
- Digital and analog outputs feed data loggers and monitoring platforms.
What are the technical specifications?
A typical uv fluorescence so2 analyzer configuration offers measurement principle of UV fluorescence at 214 nm, measurement range of 0–500 ppb, 0–2000 ppb selectable, lower detection limit of 0.4 ppb (2σ), response time of ≤ 60 s to 95%, zero drift of < 1 ppb per 24 h and span drift of < 1% per 24 h. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The UV Fluorescence SO2 Analyzer is used in national air quality monitoring networks, coal-fired power plant perimeter monitoring, non-ferrous smelter fence-line checks and urban background and traffic stations. Across the wider Gas Analyzers class, laboratories also deploy it for urban air quality monitoring networks, industrial fence-line and plant perimeter monitoring and roadside and traffic-related pollution studies.
Which standards and certifications apply?
Relevant standards and methods include EN 14212 (SO2), EN 14211 (NOx), EN 14626 (CO), ISO 13964 (ozone), US EPA 40 CFR Part 50 Appendix A and HJ 654. Certification candidates for this model are CE, China environmental monitoring instrument certification and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install analyzers in a temperature-controlled shelter or rack with clean, dry sample lines and a manifold that provides stable flow. Calibrate with certified gas standards and a dynamic dilution system, performing zero and span checks on the schedule required by the method, and keep records of converter efficiency for NOx instruments. Replace particulate filters, dryers and pump diaphragms regularly, and verify sample flow and pressure. Protect optical components from dust and condensation, and allow warm-up and stabilization before reporting data. For regulatory networks, follow quality assurance and quality control procedures such as US EPA 40 CFR Part 58 Appendix A and retain raw data for audit.
How do I select the right UV Fluorescence SO2 Analyzer?
Select this analyzer when regulatory SO2 data of reference quality is required and when aromatic interference must be suppressed. Electrochemical SO2 sensors are cheaper but drift and lack the selectivity for networks. In an RFQ, specify the range, detection limit, required method compliance, output protocols and calibration support.
How does it compare with other Gas Analyzers variants?
Choose the analyzer by the gas, the required measurement range and whether the data must satisfy a regulatory method. Reference-grade instruments follow EN or US EPA methods and provide the stability, detection limit and averaging time that monitoring networks require. Range should bracket the local concentrations and include the limit value, for example 0–500 ppb for SO2 and NOx in urban air or 0–50 ppm for CO near traffic. Consider interference rejection, response time, zero and span drift specifications and the calibration gas requirements. For indoor or occupational checks, portable or electrochemical analyzers with lower ranges and simpler calibration often suffice. Confirm output protocols, data logging and the availability of a multipoint calibration system.
Full specifications
| Measurement principle | UV fluorescence at 214 nm |
|---|---|
| Measurement range | 0–500 ppb, 0–2000 ppb selectable |
| Lower detection limit | 0.4 ppb (2σ) |
| Response time | ≤ 60 s to 95% |
| Zero drift | < 1 ppb per 24 h |
| Span drift | < 1% per 24 h |
| Sample flow rate | 0.5–1.0 L/min |
| Outputs | 4–20 mA, RS-232/RS-485, Ethernet |
| Operating temperature | 5–40 °C |
| Power supply | 220 VAC, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- National air quality monitoring networks
- Coal-fired power plant perimeter monitoring
- Non-ferrous smelter fence-line checks
- Urban background and traffic stations
Key features
- Pulsed UV lamp and photomultiplier give low nanogram-level detection limits.
- Hydrocarbon scrubber removes aromatic interference from traffic and industry.
- Wide linear range covers background and polluted urban concentrations.
- Internal temperature and pressure compensation stabilises readings.
- Automatic zero and span checks record drift against stored values.
- Digital and analog outputs feed data loggers and monitoring platforms.
Frequently asked questions about UV Fluorescence SO2 Analyzer
Aromatic hydrocarbons such as xylene and toluene fluoresce in the same ultraviolet region and would be counted as SO2, producing a positive bias. The scrubber removes them before the sample enters the fluorescence cell and is replaced on a fixed schedule.
Modern UV fluorescence analyzers reach about 0.4 ppb at two sigma with a 60-second averaging time, well below the 75 ppb hourly standard used in many countries. Lower detection limits can be achieved with longer averaging.
A single analyzer measures one sample stream at a time, so multiple points require either multiple analyzers or a multiplexed manifold with solenoid valves that switches streams. Multiplexing reduces cost but lowers the time resolution at each point.
Most networks measure sulfur dioxide, nitrogen oxides, carbon monoxide, ozone and particulate matter, with some adding ammonia, hydrogen sulfide and volatile organic compounds. The exact set is defined by the national or regional air quality standard and the local emission sources.
A gas-phase titration unit with certified nitric oxide and ozone, or a certified NO2 standard, is used to compare the analyzer response before and after the converter. Efficiency of 96 to 102 percent is normally required by reference methods, and low values indicate a depleted or fouled converter.
Zero and span checks are usually performed daily or weekly, with a full multipoint calibration every one to six months depending on the method and network requirements. Drift specifications and data-validity rules in the applicable quality assurance plan set the exact intervals.