What are Sample Preparation?

Sample preparation equipment for diagnostic laboratories prepares patient specimens such as serum, plasma, stool, sputum, swabs and tissue for testing. It covers aliquotting stations, heat inactivation baths, specimen homogenizers, fecal preparation systems and blood smear preparation devices.

5 models of Sample Preparation

The 5 models below are current configurations; specifications are confirmed on quotation.

Automated Aliquotting Station for Diagnostic Specimens

诊断样本自动分装工作站

  • SAM-0001
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Aliquot volume range:
0.2–10 mL programmable
Volume accuracy:
±2 % at 1 mL
Tubes per primary specimen:
1–6 secondary tubes
Throughput:
60–150 aliquots/h
Primary tube types:
13–16 mm diameter serum and EDTA tubes
Tip handling:
Disposable tips or washed fixed probe

An automated aliquotting station splits serum, plasma or other diagnostic specimens from primary tubes into labelled secondary tubes with defined volumes. It suits laboratories that archive specimens for repeat testing and want to avoid manual pipetting errors and cross-contamination.

Request a quote
View details

Serum and Plasma Heat Inactivation Bath

血清与血浆热灭活水浴

  • SAM-0002
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Temperature range:
Ambient to 80 °C, set point 56 °C
Temperature uniformity:
±0.5 °C across the working area
Capacity:
12–60 tube positions of 13–16 mm
Timer:
1 min to 99 h with audible alarm
Heating medium:
Water bath or dry aluminium block
Safety features:
Over-temperature cut-off and low-level protection

A heat inactivation bath or block holds serum or plasma at 56 degrees Celsius for a defined period to reduce infectivity before batch testing. It suits serology and molecular laboratories that process potentially infectious specimens outside a biosafety cabinet.

Request a quote
View details

Bead Mill Homogenizer for Diagnostic Specimens

诊断标本珠磨匀浆仪

  • SAM-0003
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Oscillation speed:
Up to 4,000–7,000 oscillations/min
Processing time:
10 s to 5 min programmable
Capacity:
1–96 tubes depending on format
Cooling:
Optional, 0–10 °C chamber
Bead materials:
Stainless steel, zirconia or glass beads
Tube formats:
2 mL microtubes to 96-well plate adapters

A bead mill homogenizer disrupts swabs, sputum, tissue and stool specimens with high-speed beads inside a sealed tube, releasing organisms and analytes for downstream testing. It suits molecular and microbiology workflows that need reproducible specimen disruption.

Request a quote
View details

Automated Fecal Sample Preparation System

粪便样本自动前处理系统

  • SAM-0004
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Sample mass:
10–50 mg per collection with calibrated probe
Buffer volume:
1–10 mL programmable
Dilution factor:
Fixed per device geometry, typically 1:50 to 1:200
Mixing:
Orbital or vortex mixing for 5–60 s
Throughput:
20–60 samples/h
Sample mass accuracy:
±10 % with the specified collection device

This system prepares stool specimens for quantitative fecal tests by sampling a defined mass, mixing it with buffer and delivering the extract to a test device or tube. It suits laboratories performing fecal immunochemical or calprotectin testing where sample mass must be reproducible.

Request a quote
View details

Automated Blood Smear Preparation System

自动血涂片制备系统

  • SAM-0005
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)
Sample volume:
2–10 µL blood per slide
Spread parameters:
Adjustable angle, drop volume and speed
Hematocrit adjustment:
Preset profiles for low, normal and high Hct
Stain:
Romanowsky-type stain, onboard bottles
Throughput:
30–60 slides/h
Slide identification:
Printed identifier or barcode label

An automated blood smear preparation system aspirates blood, spreads a monolayer slide and stains it with a Romanowsky stain at defined settings. It suits hematology workflows that need consistent films for morphological review, including veterinary and research laboratories.

Request a quote
View details

Compare Sample Preparation models

ModelThroughputCapacityData recordsPower supply
Automated Aliquotting Station for Diagnostic SpecimensSAM-000160–150 aliquots/h———
Serum and Plasma Heat Inactivation BathSAM-0002—12–60 tube positions of 13–16 mmBatch time and temperature logging with exportAC 100–240 V, 50/60 Hz
Bead Mill Homogenizer for Diagnostic SpecimensSAM-0003—1–96 tubes depending on formatProgram and run logging with exportAC 100–240 V, 50/60 Hz
Automated Fecal Sample Preparation SystemSAM-000420–60 samples/h—Specimen identifier, mass class and buffer volume loggedAC 100–240 V, 50/60 Hz
Automated Blood Smear Preparation SystemSAM-000530–60 slides/h—Run log with slide identificationAC 100–240 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Sample Preparation work?

Diagnostic sample preparation changes a specimen so that a downstream assay can measure it reliably. Serum and plasma are separated from cells by centrifugation and then aliquoted into labelled tubes, which reduces thaw cycles and cross-contamination during archiving. Some serology and molecular workflows require heat inactivation, typically at 56 degrees Celsius for thirty minutes, to reduce infectivity before handling. Solid or viscous specimens such as stool, sputum, swabs and tissue must be homogenised, liquefied or extracted into a buffer so that target organisms or analytes are released uniformly. Fecal immunochemical tests need a defined sample mass mixed with buffer, and blood film preparation requires a controlled spread and stain so that cells can be examined morphologically. Each step influences the analytical result, so volume accuracy, temperature control and traceability matter as much as in the analytical instrument itself.

Which Sample Preparation variants are available?

  • Automated Aliquotting Station for Diagnostic Specimens — An automated aliquotting station splits serum, plasma or other diagnostic specimens from primary tubes into labelled secondary tubes with defined volumes.
  • Serum and Plasma Heat Inactivation Bath — A heat inactivation bath or block holds serum or plasma at 56 degrees Celsius for a defined period to reduce infectivity before batch testing.
  • Bead Mill Homogenizer for Diagnostic Specimens — A bead mill homogenizer disrupts swabs, sputum, tissue and stool specimens with high-speed beads inside a sealed tube, releasing organisms and analytes for downstream testing.
  • Automated Fecal Sample Preparation System — This system prepares stool specimens for quantitative fecal tests by sampling a defined mass, mixing it with buffer and delivering the extract to a test device or tube.
  • Automated Blood Smear Preparation System — An automated blood smear preparation system aspirates blood, spreads a monolayer slide and stains it with a Romanowsky stain at defined settings.

How do I choose the right variant?

Start from the specimen types you receive and the assays that follow, since a device is only useful if its process matches the downstream kit requirements. For aliquotting, check the number of tubes per primary sample, the dead volume, the liquid class accuracy for viscous specimens and the labelling method. For heat inactivation, confirm the temperature uniformity across the bath or block, the capacity per batch and whether a lid is needed to limit evaporation. For homogenisation, choose between bead milling, rotor-stator and paddle systems according to specimen hardness and the need to keep analytes intact. For fecal and blood smear preparation, confirm the sample mass or film quality specification. In all cases, ask for process validation data and confirm that consumables are available locally.

Where are Sample Preparation used?

Sample Preparation are specified in serum and plasma aliquotting for serology and molecular testing, heat inactivation of serum before batch serology, stool and sputum processing for infectious disease testing and blood film preparation for morphological review.

Which standards and certifications apply?

Work with Sample Preparation is commonly governed by ISO 15189, ISO 15190, CLSI GP16, CLSI M29, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Verify each device at installation with gravimetric volume checks, temperature mapping and, where relevant, recovery or uniformity studies using spiked specimens. Write procedures that define specimen acceptance, batch size, temperature and time limits, and the identification of each aliquot, because traceability between the primary tube and derived aliquots is frequently examined during accreditation. Clean and decontaminate surfaces, rotors and homogenisation chambers after each batch, and use sealed or disposable components where aerosols are a risk. Record maintenance, calibration and validation data, and review temperature records for heat inactivation and incubation steps. Treat all specimens, consumables and waste as potentially infectious.

Frequently asked questions about Sample Preparation

Heat inactivation at 56 degrees Celsius for about thirty minutes reduces the infectivity of serum and plasma before they are handled in batches or outside a biosafety cabinet, which lowers the risk to staff. It must be validated for each assay, because heating can degrade some analytes and enzymes.