Serum and Plasma Heat Inactivation Bath
血清与血浆热灭活水浴
- SKU SAM-0002
- Sample Preparation
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient to 80 °C, set point 56 °C |
|---|---|
| Temperature uniformity | ±0.5 °C across the working area |
| Capacity | 12–60 tube positions of 13–16 mm |
| Timer | 1 min to 99 h with audible alarm |
| Heating medium | Water bath or dry aluminium block |
| Safety features | Over-temperature cut-off and low-level protection |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, ISO 15190, CLSI GP16
What is the Serum and Plasma Heat Inactivation Bath?
A heat inactivation bath or block holds serum or plasma at 56 degrees Celsius for a defined period to reduce infectivity before batch testing. It suits serology and molecular laboratories that process potentially infectious specimens outside a biosafety cabinet.
What is the Serum and Plasma Heat Inactivation Bath?
A heat inactivation bath or block holds serum or plasma at 56 degrees Celsius for a defined period to reduce infectivity before batch testing. It suits serology and molecular laboratories that process potentially infectious specimens outside a biosafety cabinet.
Overview
The device maintains water or a dry block at 56 degrees Celsius, and specimens in capped tubes are immersed or inserted for the validated time, usually thirty minutes after the sample reaches temperature. Temperature uniformity matters more than the set point alone, because an inadequately heated tube remains infectious while an overheated one loses analyte. Thermostatic control, over-temperature protection and an independent thermometer for verification are standard requirements, and lids reduce evaporation and aerosol escape. Capacity ranges from a few tubes for a small serology laboratory to more than fifty positions for a blood bank or large serology unit. Records of time and temperature per batch support the traceability expected in accreditation, and the device should also be validated for the recovery of the analytes you report.
How does it work?
Diagnostic sample preparation changes a specimen so that a downstream assay can measure it reliably. Serum and plasma are separated from cells by centrifugation and then aliquoted into labelled tubes, which reduces thaw cycles and cross-contamination during archiving. Some serology and molecular workflows require heat inactivation, typically at 56 degrees Celsius for thirty minutes, to reduce infectivity before handling. Solid or viscous specimens such as stool, sputum, swabs and tissue must be homogenised, liquefied or extracted into a buffer so that target organisms or analytes are released uniformly. Fecal immunochemical tests need a defined sample mass mixed with buffer, and blood film preparation requires a controlled spread and stain so that cells can be examined morphologically. Each step influences the analytical result, so volume accuracy, temperature control and traceability matter as much as in the analytical instrument itself.
What are the key features?
- Temperature control at 56 °C with uniformity specification
- Over-temperature protection and independent verification thermometer
- Water bath or dry block design for capped tubes
- Lid to reduce evaporation and aerosol escape
- Capacity from a few tubes to more than fifty positions
- Batch time and temperature recording with alarm logging
What are the technical specifications?
A typical serum and plasma heat inactivation bath configuration offers temperature range of Ambient to 80 °C, set point 56 °C, temperature uniformity of ±0.5 °C across the working area, capacity of 12–60 tube positions of 13–16 mm, timer of 1 min to 99 h with audible alarm, heating medium of Water bath or dry aluminium block and safety features of Over-temperature cut-off and low-level protection. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Serum and Plasma Heat Inactivation Bath is used in serum inactivation before batch serology, complement inactivation for immunoassays, specimen preparation for molecular testing and blood bank and donor screening workflows. Across the wider Sample Preparation class, laboratories also deploy it for serum and plasma aliquotting for serology and molecular testing, heat inactivation of serum before batch serology and stool and sputum processing for infectious disease testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, ISO 15190, CLSI GP16, CLSI M29, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Verify each device at installation with gravimetric volume checks, temperature mapping and, where relevant, recovery or uniformity studies using spiked specimens. Write procedures that define specimen acceptance, batch size, temperature and time limits, and the identification of each aliquot, because traceability between the primary tube and derived aliquots is frequently examined during accreditation. Clean and decontaminate surfaces, rotors and homogenisation chambers after each batch, and use sealed or disposable components where aerosols are a risk. Record maintenance, calibration and validation data, and review temperature records for heat inactivation and incubation steps. Treat all specimens, consumables and waste as potentially infectious.
How do I select the right Serum and Plasma Heat Inactivation Bath?
Specify this device when heat inactivation is part of your standard workflow and capacity per batch is known. In the RFQ confirm temperature uniformity rather than set point accuracy alone, the time needed for specimens to reach 56 degrees Celsius, the lid design, and whether batch time and temperature can be exported for records.
How does it compare with other Sample Preparation variants?
Start from the specimen types you receive and the assays that follow, since a device is only useful if its process matches the downstream kit requirements. For aliquotting, check the number of tubes per primary sample, the dead volume, the liquid class accuracy for viscous specimens and the labelling method. For heat inactivation, confirm the temperature uniformity across the bath or block, the capacity per batch and whether a lid is needed to limit evaporation. For homogenisation, choose between bead milling, rotor-stator and paddle systems according to specimen hardness and the need to keep analytes intact. For fecal and blood smear preparation, confirm the sample mass or film quality specification. In all cases, ask for process validation data and confirm that consumables are available locally.
Full specifications
| Temperature range | Ambient to 80 °C, set point 56 °C |
|---|---|
| Temperature uniformity | ±0.5 °C across the working area |
| Capacity | 12–60 tube positions of 13–16 mm |
| Timer | 1 min to 99 h with audible alarm |
| Heating medium | Water bath or dry aluminium block |
| Safety features | Over-temperature cut-off and low-level protection |
| Verification | Independent reference thermometer port |
| Data records | Batch time and temperature logging with export |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Serum inactivation before batch serology
- Complement inactivation for immunoassays
- Specimen preparation for molecular testing
- Blood bank and donor screening workflows
Key features
- Temperature control at 56 °C with uniformity specification
- Over-temperature protection and independent verification thermometer
- Water bath or dry block design for capped tubes
- Lid to reduce evaporation and aerosol escape
- Capacity from a few tubes to more than fifty positions
- Batch time and temperature recording with alarm logging
Frequently asked questions about Serum and Plasma Heat Inactivation Bath
No. The validated incubation time usually starts when the specimen reaches 56 degrees Celsius, so an equilibration period must be added for cold or large-volume tubes. Laboratories should measure the equilibration time for the tube types and volumes they use and document it in the procedure.
It can reduce the activity of some enzymes and labile proteins and may alter the results of certain immunoassays, so each assay must be validated after inactivation. Laboratories that report both inactivated and untreated specimens should keep the procedures separate and document which was used.
Water baths transfer heat faster and give good uniformity for capped tubes, but they need regular cleaning and level checks and carry a contamination risk if tubes leak. Dry blocks avoid water contamination and are easier to maintain, though equilibration can be slower for large volumes.
Verify with a calibrated independent thermometer at installation, after any service that affects the heating element, and at a defined routine interval, and record the results. Some laboratories verify before each batch using a reference probe in a dummy tube.
Heat inactivation at 56 degrees Celsius for about thirty minutes reduces the infectivity of serum and plasma before they are handled in batches or outside a biosafety cabinet, which lowers the risk to staff. It must be validated for each assay, because heating can degrade some analytes and enzymes.
It depends on the primary tube volume, the dead volume of the pipetting system, and the volume required per test. Laboratories usually plan two to four aliquots per serum tube to limit thaw cycles, and the pipetting station should be specified with the minimum deliverable volume that remains accurate.
Bead milling with stainless steel or ceramic beads suits fibrous tissue and tough specimens, while rotor-stator homogenisers handle larger volumes of sputum and tissue quickly. Chemical liquefaction with a reducing agent such as dithiothreitol is often combined with mechanical processing for sputum in mycobacteriology.
Related models