Point-of-Care INR Coagulation Meter
床旁 INR 凝血仪
- SKU PCD-0003
- Point-of-Care Diagnostics
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
- NMPA registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sample type | Fresh capillary or venous whole blood |
|---|---|
| Sample volume | 10–15 µL |
| INR range | 0.8–8.0 |
| Time to result | 30–60 s |
| Hematocrit range | 25–55% |
| Memory | ≥ 300 results |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 22870, ISO 15197, ISO 15189
What is the Point-of-Care INR Coagulation Meter?
A point-of-care INR coagulation meter measures prothrombin time from a fingerstick blood drop and reports the international normalized ratio in about one minute. It is selected by anticoagulation clinics, pharmacies and patients on warfarin for rapid dose adjustment.
What is the Point-of-Care INR Coagulation Meter?
A point-of-care INR coagulation meter measures prothrombin time from a fingerstick blood drop and reports the international normalized ratio in about one minute. It is selected by anticoagulation clinics, pharmacies and patients on warfarin for rapid dose adjustment.
Overview
This variant is a handheld meter using disposable test strips containing thromboplastin reagent. A drop of capillary blood of 10 to 15 microliters is applied, and the meter detects clot formation through electrochemical or optical changes, such as blood movement or impedance, and converts clotting time to INR using a lot-specific calibration code. Measurement range is typically 0.8 to 8.0 INR, with results in 30 to 60 seconds. Some models support patient self-testing with memory and connectivity. Accuracy can differ from laboratory plasma methods at high INR values and in conditions such as lupus anticoagulant or high hematocrit, so laboratory confirmation is recommended for out-of-range or discordant results. Strips are stored per manufacturer instructions.
How does it work?
Point-of-care devices miniaturize laboratory methods into compact instruments and single-use test formats. Lateral flow immunoassays wick the sample along a membrane where labeled antibodies form visible or fluorescent lines at capture zones, and a reader quantifies line intensity. Electrochemical biosensors measure current or potential produced by enzymatic reactions on printed electrodes, as in glucose and lactate testing. Cartridge analyzers combine microfluidics with ion-selective electrodes or optical detection for blood gases and chemistry. Coagulation meters detect clot formation by impedance or light scattering changes. Compact hematology analyzers use impedance counting and colorimetric hemoglobin measurement. Built-in quality checks, lot calibration and connectivity support reliable use by non-laboratory operators.
What are the key features?
- Fingerstick capillary blood sample of 10–15 µL
- INR result in 30 to 60 seconds with disposable strips
- Lot-specific calibration via code chip or barcode
- Measuring range of 0.8–8.0 INR with out-of-range warnings
- Result memory and optional connectivity for clinic or self-testing
- Built-in electronic quality control check at each test
What are the technical specifications?
A typical point-of-care inr coagulation meter configuration offers sample type of Fresh capillary or venous whole blood, sample volume of 10–15 µL, INR range of 0.8–8.0, time to result of 30–60 s, hematocrit range of 25–55% and memory of ≥ 300 results. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Point-of-Care INR Coagulation Meter is used in warfarin dose monitoring in anticoagulation clinics, patient self-testing and self-management, pharmacy and primary care testing and preoperative coagulation screening. Across the wider Point-of-Care Diagnostics class, laboratories also deploy it for emergency department rapid testing, primary care clinic testing and anticoagulation monitoring.
Which standards and certifications apply?
Relevant standards and methods include ISO 22870, ISO 15197, ISO 15189, IEC 61010-2-101, CLSI POCT12, CLSI POCT14, ISO 13485 and EN 13532. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Point-of-care testing is often performed by non-laboratory staff, so governance is essential. Establish a program covering operator training, competency assessment, quality control schedules, external quality assessment and documentation, with oversight from a laboratory. Store strips and cartridges within labeled temperature ranges and check expiry dates. Keep meters clean and disinfected between patients with approved disinfectants, since contamination with blood is a risk. Understand known interferences such as hematocrit, oxygen or medications for each device. Ensure results are transmitted to patient records, and confirm critical or unexpected values with laboratory methods. Comply with local regulations on device use, waste handling and data protection.
How do I select the right Point-of-Care INR Coagulation Meter?
Choose an INR meter for warfarin monitoring where rapid results and dose adjustment at the visit are required. Specify the INR range, sample volume, strip storage, self-testing need, memory and connectivity, and request correlation data with laboratory plasma INR in the RFQ.
How does it compare with other Point-of-Care Diagnostics variants?
Select by clinical need, operator skill and connectivity. Define the tests needed at the point of care and their required turnaround, then check the analytical performance against laboratory methods for the intended population. Consider sample type and volume, ease of use, cartridge or strip storage, calibration and quality control requirements, and operator lockout and certification features. Connectivity to hospital or laboratory information systems matters for record keeping and oversight. Compare cost per test, including consumables and quality control, with central laboratory testing. Confirm regulatory status for intended use, and arrange training, competency assessment and oversight by the laboratory, following ISO 22870 where applicable. Verify the supplier's ability to maintain consumable supply.
Full specifications
| Sample type | Fresh capillary or venous whole blood |
|---|---|
| Sample volume | 10–15 µL |
| INR range | 0.8–8.0 |
| Time to result | 30–60 s |
| Hematocrit range | 25–55% |
| Memory | ≥ 300 results |
| Strip storage | 2–30 °C (per instructions) |
| Weight | ≈ 100–200 g |
| Operating temperature | 15–35 °C |
| Power supply | 2 × AAA batteries or rechargeable |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Warfarin dose monitoring in anticoagulation clinics
- Patient self-testing and self-management
- Pharmacy and primary care testing
- Preoperative coagulation screening
Key features
- Fingerstick capillary blood sample of 10–15 µL
- INR result in 30 to 60 seconds with disposable strips
- Lot-specific calibration via code chip or barcode
- Measuring range of 0.8–8.0 INR with out-of-range warnings
- Result memory and optional connectivity for clinic or self-testing
- Built-in electronic quality control check at each test
Frequently asked questions about Point-of-Care INR Coagulation Meter
Point-of-care INR correlates well with laboratory values in the therapeutic range of 2.0 to 3.5 and is widely used for warfarin monitoring, but differences increase at high INR or with interfering conditions. Discordant or critical values should be confirmed in the laboratory.
Yes, selected patients who have been trained can self-test using INR meters designed for that purpose, often reporting results to a clinic. Programs should include training, regular comparison with laboratory results and clear instructions for out-of-range values.
Factors include hematocrit outside the stated range, lupus anticoagulant, sample handling delay, strip storage and technique, and very high INR values. Operators should follow the instructions for use and confirm unexpected results with a laboratory method.
Point-of-care testing is diagnostic testing performed at or near the patient, such as in a clinic, emergency department or home, using compact devices that give results in minutes. It supports faster clinical decisions compared with sending samples to a central laboratory.
Many point-of-care devices correlate well with laboratory methods for their intended use, but precision is often lower and some have specific interferences. Laboratories verify performance locally, run quality control and confirm critical or unexpected results with a central method.
Devices are designed for nurses, physicians and trained non-laboratory staff, with simple interfaces and operator lockout requiring certification. Some, such as glucose meters, are used by patients. A laboratory or quality manager typically oversees training and quality control.
Related models