Automated Aliquotting Station for Diagnostic Specimens — product photo

Automated Aliquotting Station for Diagnostic Specimens

诊断样本自动分装工作站

  • SKU SAM-0001
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Aliquot volume range0.2–10 mL programmable
Volume accuracy±2 % at 1 mL
Tubes per primary specimen1–6 secondary tubes
Throughput60–150 aliquots/h
Primary tube types13–16 mm diameter serum and EDTA tubes
Tip handlingDisposable tips or washed fixed probe
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, ISO 15190, CLSI GP16

What is the Automated Aliquotting Station for Diagnostic Specimens?

An automated aliquotting station splits serum, plasma or other diagnostic specimens from primary tubes into labelled secondary tubes with defined volumes. It suits laboratories that archive specimens for repeat testing and want to avoid manual pipetting errors and cross-contamination.

What is the Automated Aliquotting Station for Diagnostic Specimens?

An automated aliquotting station splits serum, plasma or other diagnostic specimens from primary tubes into labelled secondary tubes with defined volumes. It suits laboratories that archive specimens for repeat testing and want to avoid manual pipetting errors and cross-contamination.

Overview

The station reads the primary tube barcode, aspirates a measured volume with a disposable tip or a fixed probe, dispenses it into one or more secondary tubes, and prints or applies labels that carry the specimen identifier, aliquot number, date and storage location. Liquid-level detection prevents aspiration of cells or clots, and conductivity or pressure sensing verifies the delivered volume for each aliquot. Programs can be defined per specimen type, with different volumes for serology, molecular testing and archiving. Carryover is controlled by tip changes or by wash cycles and should be verified with high-low sequences. Because each aliquot becomes an independent record, the software must be able to report which primary specimen each derived tube came from.

How does it work?

Diagnostic sample preparation changes a specimen so that a downstream assay can measure it reliably. Serum and plasma are separated from cells by centrifugation and then aliquoted into labelled tubes, which reduces thaw cycles and cross-contamination during archiving. Some serology and molecular workflows require heat inactivation, typically at 56 degrees Celsius for thirty minutes, to reduce infectivity before handling. Solid or viscous specimens such as stool, sputum, swabs and tissue must be homogenised, liquefied or extracted into a buffer so that target organisms or analytes are released uniformly. Fecal immunochemical tests need a defined sample mass mixed with buffer, and blood film preparation requires a controlled spread and stain so that cells can be examined morphologically. Each step influences the analytical result, so volume accuracy, temperature control and traceability matter as much as in the analytical instrument itself.

What are the key features?

  • Barcode reading of primary tubes with label printing for aliquots
  • Liquid-level and clot detection during aspiration
  • Programmable volumes per specimen type and destination
  • Disposable tips or washed fixed probe for carryover control
  • Volume verification by pressure or conductivity sensing
  • Full traceability between primary and derived specimen identifiers

What are the technical specifications?

A typical automated aliquotting station for diagnostic specimens configuration offers aliquot volume range of 0.2–10 mL programmable, volume accuracy of ±2 % at 1 mL, tubes per primary specimen of 1–6 secondary tubes, throughput of 60–150 aliquots/h, primary tube types of 13–16 mm diameter serum and EDTA tubes and tip handling of Disposable tips or washed fixed probe. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Aliquotting Station for Diagnostic Specimens is used in serum banking for repeat serology, molecular testing specimen archiving, clinical trial sample division and reference laboratory specimen distribution. Across the wider Sample Preparation class, laboratories also deploy it for serum and plasma aliquotting for serology and molecular testing, heat inactivation of serum before batch serology and stool and sputum processing for infectious disease testing.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, ISO 15190, CLSI GP16, CLSI M29, CLSI EP05, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Verify each device at installation with gravimetric volume checks, temperature mapping and, where relevant, recovery or uniformity studies using spiked specimens. Write procedures that define specimen acceptance, batch size, temperature and time limits, and the identification of each aliquot, because traceability between the primary tube and derived aliquots is frequently examined during accreditation. Clean and decontaminate surfaces, rotors and homogenisation chambers after each batch, and use sealed or disposable components where aerosols are a risk. Record maintenance, calibration and validation data, and review temperature records for heat inactivation and incubation steps. Treat all specimens, consumables and waste as potentially infectious.

How do I select the right Automated Aliquotting Station for Diagnostic Specimens?

Specify this station when specimens are frequently archived or distributed, or when manual aliquotting is a recognised source of labelling errors. In the RFQ state the specimen types, the required aliquot volumes and tolerances, the number of tubes per specimen, the labelling format used locally, and whether the LIS can accept the derived identifiers.

How does it compare with other Sample Preparation variants?

Start from the specimen types you receive and the assays that follow, since a device is only useful if its process matches the downstream kit requirements. For aliquotting, check the number of tubes per primary sample, the dead volume, the liquid class accuracy for viscous specimens and the labelling method. For heat inactivation, confirm the temperature uniformity across the bath or block, the capacity per batch and whether a lid is needed to limit evaporation. For homogenisation, choose between bead milling, rotor-stator and paddle systems according to specimen hardness and the need to keep analytes intact. For fecal and blood smear preparation, confirm the sample mass or film quality specification. In all cases, ask for process validation data and confirm that consumables are available locally.

Full specifications

Full specifications
Aliquot volume range0.2–10 mL programmable
Volume accuracy±2 % at 1 mL
Tubes per primary specimen1–6 secondary tubes
Throughput60–150 aliquots/h
Primary tube types13–16 mm diameter serum and EDTA tubes
Tip handlingDisposable tips or washed fixed probe
LabellingPrinted barcode labels with date and aliquot number
Data storage50,000 aliquot records
InterfacesLAN with LIS connection and barcode output

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Serum banking for repeat serology
  • Molecular testing specimen archiving
  • Clinical trial sample division
  • Reference laboratory specimen distribution

Key features

  • Barcode reading of primary tubes with label printing for aliquots
  • Liquid-level and clot detection during aspiration
  • Programmable volumes per specimen type and destination
  • Disposable tips or washed fixed probe for carryover control
  • Volume verification by pressure or conductivity sensing
  • Full traceability between primary and derived specimen identifiers

Frequently asked questions about Automated Aliquotting Station for Diagnostic Specimens

Disposable tips eliminate carryover at the cost of consumables, while fixed probes rely on wash cycles whose performance must be verified with high-low sequences. For molecular testing, carryover control is especially important, so tip-based systems are usually preferred.

Request a quotation for the Automated Aliquotting Station for Diagnostic Specimens

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.