Blood Bank Refrigerators

血库冰箱

BLO · Blood Bank Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: AABB Standards for Blood Banks and Transfusion Services, Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, IEC 61010-2-011

Standards referenced

  • AABB Standards for Blood Banks and Transfusion Services
  • Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components
  • IEC 61010-2-011
  • IEC 61010-1
  • IEC 61326-1
  • ISO 13485

What are Blood Bank Refrigerators?

Blood bank refrigerators are temperature-controlled cabinets that hold whole blood and red cell components at 2–6 °C, and platelet incubators that hold platelets at 20–24 °C with agitation. Blood banks, hospital transfusion services and blood collection centers use them to preserve component viability and keep a continuous, auditable temperature record.

5 models of Blood Bank Refrigerators

The 5 models below are current configurations; specifications are confirmed on quotation.

Upright Blood Bank Refrigerator

立式血库冰箱

  • BLO-0001
  • Blood Bank Refrigerators
  • CE (to be confirmed)
  • ISO 13485 (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
2–6 °C (set point 4 °C)
Uniformity:
≤ ±2 °C in loaded chamber
Net capacity:
300–700 L
Blood bag capacity:
approx. 200–600 bags (450 mL)
Refrigerant:
R600a or R290
Control:
Microprocessor with RTD sensor

An upright blood bank refrigerator is a floor-standing cabinet with a hinged door, adjustable shelves or bag racks and a 2–6 °C controlled chamber. It suits hospital transfusion laboratories and donor centers that need moderate capacity with a clear view of inventory and full alarm monitoring.

Request a quote
View details

Undercounter Blood Bank Refrigerator

台下式血库冰箱

  • BLO-0002
  • Blood Bank Refrigerators
  • CE (to be confirmed)
  • ISO 13485 (to be confirmed)
  • RoHS (to be confirmed)
Temperature range:
2–6 °C
Net capacity:
100–200 L
Blood bag capacity:
approx. 60–150 bags (450 mL)
Dimensions (W×D×H):
600 × 650 × 830 mm
Uniformity:
≤ ±2 °C
Refrigerant:
R600a

An undercounter blood bank refrigerator is a compact 2–6 °C cabinet, typically 100–200 L, that fits below a laboratory bench. It suits small hospital blood banks, operating theaters and clinics needing a few dozen units with the same alarm and recording features as larger models.

Request a quote
View details

Drawer-Type Blood Bank Refrigerator

抽屉式血库冰箱

  • BLO-0003
  • Blood Bank Refrigerators
  • CE (to be confirmed)
  • ISO 13485 (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
2–6 °C
Net capacity:
400–1000 L
Number of drawers:
6–12
Bags per drawer:
approx. 20–40 (450 mL)
Uniformity:
≤ ±2 °C
Drawer material:
304 stainless steel or powder-coated steel

A drawer-type blood bank refrigerator stores bags in sliding drawers behind one or more doors, holding 2–6 °C. It suits high-volume blood banks that want organized storage by blood group, easier bag handling and less cold-air loss than shelves.

Request a quote
View details

Platelet Incubator with Agitator

血小板恒温振荡保存箱

  • BLO-0004
  • Blood Bank Refrigerators
  • CE (to be confirmed)
  • ISO 13485 (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
20–24 °C
Control accuracy:
±2 °C
Agitation rate:
approx. 60 cycles/min, 35 mm stroke
Capacity:
12–96 platelet bags
Agitator type:
Flatbed, horizontal
Net capacity:
100–400 L

A platelet incubator with agitator keeps platelet concentrates at 22 ± 2 °C while gently rocking the bags to maintain gas exchange. Blood banks and hospital transfusion services use it for storage of platelets for the period allowed by local regulation, usually five to seven days.

Request a quote
View details

Point-of-Care Blood Storage Refrigerator

床旁输血储血冰箱

  • BLO-0005
  • Blood Bank Refrigerators
  • CE (to be confirmed)
  • ISO 13485 (to be confirmed)
  • IEC 61010-2-011 test report (to be confirmed)
Temperature range:
2–6 °C
Capacity:
10–60 red cell units
Net capacity:
30–150 L
Access control:
Key lock, PIN or RFID card
Data logging:
Wireless or Ethernet, 1–5 min interval
Alarms:
High/low, door, power failure, battery low

A point-of-care blood storage refrigerator is a small, secured 2–6 °C cabinet placed in an operating theater, emergency department or ward to hold a limited number of red cell units. It provides controlled, traceable storage close to use, with access control and alarms.

Request a quote
View details

Compare Blood Bank Refrigerators models

ModelTemperature rangeUniformityNet capacityBlood bag capacityRefrigerant
Upright Blood Bank RefrigeratorBLO-00012–6 °C (set point 4 °C)≤ ±2 °C in loaded chamber300–700 Lapprox. 200–600 bags (450 mL)R600a or R290
Undercounter Blood Bank RefrigeratorBLO-00022–6 °C≤ ±2 °C100–200 Lapprox. 60–150 bags (450 mL)R600a
Drawer-Type Blood Bank RefrigeratorBLO-00032–6 °C≤ ±2 °C400–1000 L——
Platelet Incubator with AgitatorBLO-000420–24 °C—100–400 L——
Point-of-Care Blood Storage RefrigeratorBLO-00052–6 °C≤ ±2 °C30–150 L——

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Blood Bank Refrigerators work?

A blood bank refrigerator uses forced-air circulation over an evaporator so that the whole storage volume stays within a narrow band, typically 4 ± 2 °C. A microprocessor controller reads a platinum RTD or thermistor probe, often immersed in a glycol or glycerol buffer bottle that mimics the thermal mass of a blood bag. Independent high/low alarms, a separate recorder probe and a battery-backed alarm circuit are required so an excursion is detected even during mains failure. Door-open and power-failure alarms, sealed glass or insulated doors and an electric defrost cycle limit temperature swings. Platelet units differ: a thermostatically controlled chamber at 22 ± 2 °C holds a flatbed or elliptical agitator that keeps platelets in suspension and gas-exchanging across the bag wall.

Which Blood Bank Refrigerators variants are available?

  • Upright Blood Bank Refrigerator — An upright blood bank refrigerator is a floor-standing cabinet with a hinged door, adjustable shelves or bag racks and a 2–6 °C controlled chamber.
  • Undercounter Blood Bank Refrigerator — An undercounter blood bank refrigerator is a compact 2–6 °C cabinet, typically 100–200 L, that fits below a laboratory bench.
  • Drawer-Type Blood Bank Refrigerator — A drawer-type blood bank refrigerator stores bags in sliding drawers behind one or more doors, holding 2–6 °C.
  • Platelet Incubator with Agitator — A platelet incubator with agitator keeps platelet concentrates at 22 ± 2 °C while gently rocking the bags to maintain gas exchange.
  • Point-of-Care Blood Storage Refrigerator — A point-of-care blood storage refrigerator is a small, secured 2–6 °C cabinet placed in an operating theater, emergency department or ward to hold a limited number of red cell units.

How do I choose the right variant?

Start with the component you store: red cells and whole blood need 2–6 °C, platelets need 20–24 °C with agitation, and each needs its own cabinet. Next size the capacity in blood units (a 450 mL bag is roughly 0.5 L with racking) and choose drawers or shelves to match workflow. Check the temperature uniformity and recovery after door opening, since these determine real-world compliance. Decide on monitoring: a chart or electronic recorder, independent alarm probe, remote alarm contacts and network logging. A glass door helps inventory checks but increases heat gain. Confirm the refrigerant and ambient class for your climate zone, and whether the site requires battery backup, lockable doors or integration with a hospital monitoring system.

Where are Blood Bank Refrigerators used?

Blood Bank Refrigerators are specified in red cell and whole blood storage, platelet storage and agitation, hospital transfusion services, blood collection centers and satellite storage in operating theaters and wards.

Which standards and certifications apply?

Work with Blood Bank Refrigerators is commonly governed by AABB Standards for Blood Banks and Transfusion Services, Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, IEC 61010-2-011, IEC 61010-1, IEC 61326-1 and ISO 13485. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Place the cabinet away from heat sources and leave the manufacturer's ventilation clearance. Allow the unit to stabilize for 24 hours and run a temperature mapping study, with probes at the corners, center and door shelf, before loading blood. Calibrate probes against a traceable reference at least annually and verify alarms monthly. Clean condensers quarterly and defrost drains as required. Keep a written standard operating procedure for alarm response and a contingency plan for power failure, including transfer to a validated backup unit. Retain temperature records for the period required by the regulator or accreditation body, and never store reagents, food or specimens in a unit designated for blood.

Frequently asked questions about Blood Bank Refrigerators

Red cells and whole blood are stored at 2–6 °C, and most accreditation standards expect continuous monitoring with alarms set inside that band. Platelets are not refrigerated: they are kept at 20–24 °C with continuous agitation in a separate incubator and normally for up to five to seven days depending on local rules.

Need help specifying Blood Bank Refrigerators?