Drawer-Type Blood Bank Refrigerator
抽屉式血库冰箱
- SKU BLO-0003
- Blood Bank Refrigerators
- CE (to be confirmed)
- ISO 13485 (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | 2–6 °C |
|---|---|
| Net capacity | 400–1000 L |
| Number of drawers | 6–12 |
| Bags per drawer | approx. 20–40 (450 mL) |
| Uniformity | ≤ ±2 °C |
| Drawer material | 304 stainless steel or powder-coated steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: AABB Standards for Blood Banks and Transfusion Services, Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, IEC 61010-2-011
What is the Drawer-Type Blood Bank Refrigerator?
A drawer-type blood bank refrigerator stores bags in sliding drawers behind one or more doors, holding 2–6 °C. It suits high-volume blood banks that want organized storage by blood group, easier bag handling and less cold-air loss than shelves.
What is the Drawer-Type Blood Bank Refrigerator?
A drawer-type blood bank refrigerator stores bags in sliding drawers behind one or more doors, holding 2–6 °C. It suits high-volume blood banks that want organized storage by blood group, easier bag handling and less cold-air loss than shelves.
Overview
In this format, stainless steel or coated drawers replace fixed shelves and slide on full-extension runners, with dividers for blood group and component type. Each drawer holds roughly 20 to 40 bags laid flat, which avoids crushing and permits easy first-in first-out rotation. An upright cabinet of 400 to 1000 L can contain six to twelve drawers. Air circulates through perforated drawer bases, and a buffer probe monitors representative temperature. Because operators pull a single drawer rather than open a full shelf area, less cold air is lost per access when an insulated inner door is also used. Drawer-type units are common in central blood banks processing donations into stock by group, where labeling and inventory control matter as much as temperature.
How does it work?
A blood bank refrigerator uses forced-air circulation over an evaporator so that the whole storage volume stays within a narrow band, typically 4 ± 2 °C. A microprocessor controller reads a platinum RTD or thermistor probe, often immersed in a glycol or glycerol buffer bottle that mimics the thermal mass of a blood bag. Independent high/low alarms, a separate recorder probe and a battery-backed alarm circuit are required so an excursion is detected even during mains failure. Door-open and power-failure alarms, sealed glass or insulated doors and an electric defrost cycle limit temperature swings. Platelet units differ: a thermostatically controlled chamber at 22 ± 2 °C holds a flatbed or elliptical agitator that keeps platelets in suspension and gas-exchanging across the bag wall.
What are the key features?
- Full-extension drawers with dividers for blood group and component
- Flat bag storage avoids crushing and eases first-in first-out rotation
- Perforated drawer bases preserve airflow around each bag
- Inner insulated doors reduce cold loss per access
- Independent alarm probe and buffer-bottle monitoring
- Lockable outer door with access log option
What are the technical specifications?
A typical drawer-type blood bank refrigerator configuration offers temperature range of 2–6 °C, net capacity of 400–1000 L, number of drawers of 6–12, bags per drawer of approx. 20–40 (450 mL), uniformity of ≤ ±2 °C and drawer material of 304 stainless steel or powder-coated steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Drawer-Type Blood Bank Refrigerator is used in central blood banks, high-volume hospital transfusion services, blood component processing centers and plasma and red cell distribution. Across the wider Blood Bank Refrigerators class, laboratories also deploy it for red cell and whole blood storage, platelet storage and agitation and hospital transfusion services.
Which standards and certifications apply?
Relevant standards and methods include AABB Standards for Blood Banks and Transfusion Services, Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, IEC 61010-2-011, IEC 61010-1, IEC 61326-1 and ISO 13485. Certification candidates for this model are CE, ISO 13485 and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the cabinet away from heat sources and leave the manufacturer's ventilation clearance. Allow the unit to stabilize for 24 hours and run a temperature mapping study, with probes at the corners, center and door shelf, before loading blood. Calibrate probes against a traceable reference at least annually and verify alarms monthly. Clean condensers quarterly and defrost drains as required. Keep a written standard operating procedure for alarm response and a contingency plan for power failure, including transfer to a validated backup unit. Retain temperature records for the period required by the regulator or accreditation body, and never store reagents, food or specimens in a unit designated for blood.
How do I select the right Drawer-Type Blood Bank Refrigerator?
Pick drawer storage where blood group organization, rotation and handling speed matter more than a lower unit cost. Specify the number and depth of drawers, bag type, divider layout and whether an inner door is needed. Shelf cabinets are cheaper but give slower retrieval and more disturbance during access.
How does it compare with other Blood Bank Refrigerators variants?
Start with the component you store: red cells and whole blood need 2–6 °C, platelets need 20–24 °C with agitation, and each needs its own cabinet. Next size the capacity in blood units (a 450 mL bag is roughly 0.5 L with racking) and choose drawers or shelves to match workflow. Check the temperature uniformity and recovery after door opening, since these determine real-world compliance. Decide on monitoring: a chart or electronic recorder, independent alarm probe, remote alarm contacts and network logging. A glass door helps inventory checks but increases heat gain. Confirm the refrigerant and ambient class for your climate zone, and whether the site requires battery backup, lockable doors or integration with a hospital monitoring system.
Full specifications
| Temperature range | 2–6 °C |
|---|---|
| Net capacity | 400–1000 L |
| Number of drawers | 6–12 |
| Bags per drawer | approx. 20–40 (450 mL) |
| Uniformity | ≤ ±2 °C |
| Drawer material | 304 stainless steel or powder-coated steel |
| Alarms | High/low, door, power failure, sensor fault |
| Recorder | Electronic, USB or network output |
| Ambient range | 10–32 °C |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Central blood banks
- High-volume hospital transfusion services
- Blood component processing centers
- Plasma and red cell distribution
Key features
- Full-extension drawers with dividers for blood group and component
- Flat bag storage avoids crushing and eases first-in first-out rotation
- Perforated drawer bases preserve airflow around each bag
- Inner insulated doors reduce cold loss per access
- Independent alarm probe and buffer-bottle monitoring
- Lockable outer door with access log option
Frequently asked questions about Drawer-Type Blood Bank Refrigerator
They can, because opening one drawer behind an inner door exposes less chamber volume than a full shelf area. Stability still depends on good airflow, load distribution and the controller, so mapping remains necessary regardless of drawer design.
A typical drawer holds about 20–40 standard 450 mL bags laid flat, depending on drawer depth and dividers. Leave gaps between bags for airflow, and avoid stacking more than the manufacturer recommends to prevent bag damage.
Yes. Most drawers lift out or release from slides for cleaning with approved disinfectants. Clean with the unit empty or after transferring units to a validated backup, and allow the cabinet to return to range before reloading.
Red cells and whole blood are stored at 2–6 °C, and most accreditation standards expect continuous monitoring with alarms set inside that band. Platelets are not refrigerated: they are kept at 20–24 °C with continuous agitation in a separate incubator and normally for up to five to seven days depending on local rules.
It has tighter uniformity (often ±2 °C), a dedicated recorder and alarm probe independent of the control probe, battery-backed alarms, door-open warnings and a glycol probe bottle. Laboratory refrigerators usually lack these controls and are not intended for storing units destined for transfusion.
Probes and recorders are normally calibrated at least once a year against a traceable reference, and after any repair that affects sensors. Alarm function is tested more often, commonly monthly, and temperature mapping is repeated after relocation, major repair or when a risk assessment shows a change in load pattern.
Related models